main
John Lauer Board34 R9: connected side-fan carrier, full modeled probing pass, current evidence and narrated clips 4daaf8f

Electronic load status — Board32

AIFlow finish and export requirements have passed. Fields, eight-net and native 3D walkthroughs, current-board silkscreen review and manufacturing export validation are recorded. Delivery and final film remain open. Board32 remains routed on two copper layers with zero native DRC violations and zero unconnected pads. Current and thermal design gates now pass against the revised formal specification and fresh 0.1 mm Fields solve. The selected cooling path includes a nominal AlN isolator, three grease interfaces, a custom 2.10 mm copper spacer and a modified Wakefield125319 cooler. This is a prototype design model, not a qualified installed rating.

At 5.5 W Q1 source heat, the formal model predicts a 14.381 C junction rise and a 12.071 C case rise. The independent full-power series calculation leaves only 0.619 C against the unchanged 15 C junction-rise budget. A 7.4 percent increase in sink resistance alone consumes that margin. Contact, spreading, modified-sink convection and mounting must be verified later; no fan cooling improvement is credited. See sensitivity review.

The schematic and PCB match across 104 references and 273 connected pins. All 91 fitted model references resolve; 13 bare test pads intentionally have no body. Board32 is integrated into the control-panel twin with measured-only fan RPM. Firmware remains output locked and unflashed. Full external mechanical assembly reconciliation, controlled tolerances, sourcing and machining instructions remain design work. Physical bench qualification and the probing simulator are later scope, per the user.

The selected cooling assembly review now combines Board32 with the larger cooler envelope, raised fan, guard, harness and contact stack. Fan state checks pass in the renderer and a new review clip records the simulated ramp. Detailed heatsink geometry and mounting release remain open.

The existing AIFlow dashboard updates through SSE. A local source repair binds the Fields recording to its exact Pup session instead of a global window-title match and prevents failed walkthroughs from recording a successful step proof. Its production build, workspace tests, component/widget integration and silkscreen checks pass; source f876b3ee6f63c8bbaf5e537a05aff85d2cec3144 is published and byte-for-byte readback verified. Installed/registry AIFlow remains0.1.90.

There are 129 prior native raw takes and61 reviewed excerpts, plus new Fields, net and native silkscreen-review recordings being incorporated into the clip inventory. The42 narrated storyboard drafts remain available for human review. New narration remains blocked by the shared speech-service403. The final4–5 minute film remains unfinished. No fabrication, purchase, flashing or YouTube publication has occurred.

See completion plan, selected cooling assembly, and formal gate evidence.

Historical checkpoints (superseded by current status above)

Earlier checkpoints

Current saved board: revision 24

Front contact identities are now present on both faces. Native DRC: zero violations and zero unconnected pads. Saved PCB SHA-256 8827e2f804ff0e02766d40287416d814f66fbfa2780483ebdccd983adcb1ed26. Circuit and copper unchanged; J8 reference moved clear of the corner tag. Exact-revision Fields current screening passes; thermal screening fails. The refreshed board and nominal assembly GLBs pass the material/mask gate. Thermal qualification remains open.

Video inventory: 98 raw takes, 41 reviewed excerpts; 37 narrated storyboard drafts await human review. The newest recorded material correction restores opaque physical silkscreen without moving geometry.

Latest: board23 bottom artwork landed and verified

The native board now includes 193 bottom text items and 92 graphic segments: reference/value groups, contact tags, association lines and the prototype identity/wiki address. Exact saved readback matches the reviewed candidate; native project DRC reports zero violations and zero opens. Tracks, vias, zones, nets, pads and component placements are unchanged. Evidence and native recording.

The exact-board23 current screen passes under the assumed 35 µm surface / 25 µm barrel copper. Thermal screening still fails; installed cooling and physical qualification remain open. Front contact-function legends are being checked separately before final silkscreen acceptance. The digital-twin export is being refreshed. Firmware remains locked and unflashed.

Video inventory: 96 raw native takes, 39 reviewed excerpts, 35 storyboard candidates, and two separately labeled solver-event recordings (one reviewed excerpt, one superseded proposal). All 35 storyboard candidates have draft narration; selection, human clip review and final assembly remain unfinished.

Previous: checked native reference-label rework

AIFlow board 22 contains 48 improved reference labels. Exact non-field board data is preserved; native project DRC is zero errors, warnings and opens. Reopened native PCB and top/bottom 3D views were reviewed. The live field API refused and rolled back; the successful path was an explicitly recorded saved-file replacement. See silkscreen evidence. Bottom reference/value groups and full silkscreen acceptance remain unfinished.

Inventory: 95 raw native takes, 38 reviewed excerpts, 34 storyboard candidates and one separately identified solver-event replay. All 34 scene candidates have draft narration; human review, final selection and assembly remain unfinished. Thermal is still step 13/19; exact-board current screening passes at assumed 35 µm surface copper; board-only thermal screening fails. Finished copper, installed cooling and calibrated sensor margin remain unresolved; firmware stays locked.

Latest: native net review and temperature measurement margin

Take 92 records six power nets in native KiCad on the unchanged v85 revision. Inventory: 92 raw takes, 36 reviewed excerpts, 32 storyboard candidates. The actual STM32 tach adapter passes fake-HAL tests, and the full host suite passes. The sensor screen now names the correct 300 mm candidate; its indicated 55 C cutoff can correspond to approximately 56.19 C under the limited static tolerance screen. See trip budget. Output remains locked; physical calibration and timing remain unqualified.

The timeline is open in Hydrogen at Thermal 13/19. Fields PR11 remains open; shared Fields 0.7.8 was not replaced. Minimum finished surface and barrel copper remain a requested fabrication input. Current completion plan.

Latest review: insulating stack and fan shutdown

The AlN/PEEK nominal stack is published and take 91 is reviewed: 91 raw takes, 35 reviewed excerpts, 31 storyboard candidates. The combined tach/policy test passes 240 synthetic scheduler cases. Hardware output stays locked; physical shutdown and cooling remain unqualified. Dashboard remains Thermal 13/19, with the latest caption verified live. Finished copper clarification remains pending. See fan timing review and active completion plan.

Control-panel digital model, 10 October

Control panel 0.0.4 now has a read-only fan twin driven only by fresh valid hardware RPM. Disconnected/stale readings pause the rotor and display unknown. Native browser rendering and software mapping tests pass; no hardware connection or enable occurred. Evidence · Run instructions.

Current checkpoint — 2026-10-10, 15:50 UTC

The exact adopted board is AIFlow board 21 / candidate v85. Native DRC has zero errors, warnings and opens. All six current checks pass on the matching 0.1 mm Fields report: DUT_POS 53.48, DUT_FUSED 50.66, LOAD_POS 40.11, SHUNT_P 56.50, GND 58.18 and 5V_AUX 19.04 A/mm² surface maxima, against the unchanged 60 A/mm² screen. AIFlow also checks every plated connection and explicit physical terminal. The dashboard has advanced to Thermal (13 of 19).

The schematic/netlist/BOM and native models now include SBR10U45SP5-13. The v85 change removes one redundant track fully contained in a wider track, preserving physical copper and all other circuit intent. Both native views were refreshed and inspected. Adoption evidence · Exact report.

Thermal acceptance is still failed. The board-only model injects 5.5 W through Q1’s PCB terminal region and lacks its external case-to-heatsink path; its extreme temperatures are not a prediction of an assembled cooled unit. The actual interface, supported sink/fan mounting, duct pressure/flow and fault behavior require completion. The stock sink envelope clears all 91 fitted models and probe approaches, but this excludes mating connectors and hardware. Package sensitivity · Fan airflow review.

AIFlow 0.1.88 is published and installed with 150 tests passing, verified live presentation refresh and read-only existing-pour verification. Fields PR10 remains a separate owner-review change, and the shared runtime is not replaced. There are 90 raw takes, including static/rejected footage, 34 reviewed excerpts and 30 storyboard clips. The latest excerpt inspects a nominal insulating fastener; thermal qualification remains open. The final narrated 4–5 minute film remains unfinished.

Next: complete the package/interface/duct cooling design and represent its supported operating/fault cases; then same-input thermal acceptance, Fields/pour walkthroughs, current-board silkscreen/3D review, prototype manufacturing outputs and final video. Physical calibration, safety tests and industrial qualification remain separate from digital design acceptance. No fabrication release, order or flash has occurred.

Historical checkpoints below

Current checkpoint — 2026-10-10, fine-grid rework

The dashboard is at current analysis, step 12 of 19, with 11 stages done. Live board 19 is unchanged. The corrected annular plated-wall solver rejects the remaining shunt-path hotspot: candidate v40/v45 yields GND 58.31, LOAD_POS 56.10 and SHUNT_P 66.05 A/mm² at 0.1 mm, against the unchanged 60 screen. Candidate v52 widens the shunt bus and relocates nearby signal/drain copper; native DRC is zero errors/warnings/opens, and its fine-grid solve is running. No candidate is accepted or landed.

AIFlow 0.1.82 is pushed directly, published and installed here with 132 passing workspace tests, 57 preserved CLI commands and passing workflow checks. Colby’s installed version is not verified. Fields PRs 5, 6, 8 and 9 remain owner-reviewed source; shared Fields is unchanged.

Diode copper studies still exceed the 35 C still-air budget under the documented nominal operating-heat case. Larger areas create ground islands that must be repaired before acceptance. The MOSFET package/heatsink interface and actual airflow remain unresolved. No thermal or finish gate has passed.

71 raw takes, 18 reviewed excerpts and 14 storyboard clips are available. The latest review clip explicitly shows failed current findings. The final narrated film is not assembled. Firmware is output-locked and unflashed. See completion plan, operating heat cases, build clips and release receipt.

Earlier checkpoints (historical)

Current checkpoint — native pours accepted

Current-step gate is explicitly failed: its width-only heuristic flags DUT_POS 0.25 mm and DUT_FUSED 1.0 mm, and a same-input formal Fields report is missing. The saved main-path review proves separate continuous front-layer paths of 1.5 mm and 2.0 mm respectively (IPC-2221 estimates 8.58 C and 5.34 C at 3 A), but excludes branch loads/pad necks and does not override the gate. See design/step12-main-path-review.json. Next work is a terminal-aware capacity check and supported same-board Fields integration, not blindly widening the voltage-sense branch.

AIFlow adopted board 19 after adding two Kelvin-sense copper-pour keepouts and preserving all seven existing copper zones. Native DRC reports zero errors and zero unconnected items, with 15 inherited library warnings. Step 9 is complete with documented generic via-count exceptions, not a thermal qualification. Routing/pour proofs and outline verification passed; the timeline is at current analysis, step 12 of 19 (11 done). A repeated identical native pour plan recreated only the keepout UUIDs; full definitions and filled areas remained identical. The defect is preserved in design/step10-repeat-review.json; do not replay again. See pour review and via planning review.

The video inventory now has 67 raw takes, including static/rejected footage. The latest successful pour recording fully decodes; only brief action is suitable for the final edit. Firmware remains output-locked, unflashed and physically unqualified; its latest build is 74,004 flash bytes and 24,192 RAM bytes including reservations. Fields PR 5 remains open. Cooling, formal current/thermal gates and fabrication release remain incomplete.

Historical checkpoints

Current checkpoint — 2026-10-09, 20:21 UTC

Board 18 remains unchanged; thermal/finish gates remain open. The stock sink attachment candidate clears the current fitted-body/probe screen without proposed new PCB holes; the actual mounting stack and airflow remain unresolved. Instrument register fault-injection tests now pass, with DAC/configuration readback and coherent triggered INA226 reads. The control panel accepts explicitly unavailable sensors only while output is confirmed OFF, and refuses ARM until sensor and assembly qualification are valid. All sanitizer-backed C suites and 25 Python tests pass. The output-locked STM32 image builds at 64,688 flash bytes and 23,968 RAM bytes including reservations. No hardware was flashed.

The reviewed fan-stall replay is published and visually checked on the wiki. There are 62 raw takes, including the new Pup denial, native verification and API-result review recordings; the final narrated film is unfinished. See clip library and firmware contract.

Current checkpoint - 2026-10-09, 20:10 UTC

Board 18 remains unchanged and native-connected. A separate package cooling calculator and chart now expose contact-area conversion, package/interface/sink resistance, and the difference between a ducted-flow scenario and installed fan performance. Three numerical unit/energy-balance checks pass. This sensitivity study does not pass the thermal gate or qualify a selected assembly. See package cooling review.

Firmware ARM now rejects a hardware latch that was already high before the request. The verified low-to-high handshake is covered in both the core and framed-protocol tests. Sanitizer-backed C suites and 20 Python tests pass. The output-locked STM32 image rebuilds at 64,600 flash bytes and 23,968 reserved/used RAM bytes; no flash or physical testing occurred.

Current checkpoint - 2026-10-09, 18:19 UTC

The nine reviewed D1 thermal vias are now landed, native-saved and adopted by AIFlow. The actual saved board has zero native DRC errors and zero opens, with 15 existing library warnings. Six via coordinates differ from the offline generator by at most one nanometre per axis; this is explicitly audited, not called exact equality. Other track/via geometry matches, and filled-zone differences are below 0.000001 mm2. Both native 2D and 3D views were inspected. Formal Fields/current/thermal and finish gates remain incomplete.

A new recording shows the vias appearing around D1. It decoded and its contact sheet was reviewed; a 2x edit is in the build-clips page. The inventory now contains 58 raw takes, including rejected/static takes, not 58 finished clips.

The 40 mm heatsink's four-hole arrangement does not fit the existing layout: even its smaller hardware envelope intersects routed signals at all four proposed drills. No holes were added. Q1 already includes a 3.5 mm mounting hole at (127.46, 65.34); a package-mounted cooling assembly is being investigated, with interface, support, fan duct, electrical isolation and physical qualification unresolved.

Current checkpoint - 2026-10-09, 16:59 UTC

Fan component 0.2.3 is published and installed with the gentle 20-second hero cycle, factory flying leads, explicit added Harwin harness, grid-aligned connector symbols, mating-header footprint and static complete STEP/GLB variants. Wiki Skill Pack 0.8.42 and Component Widgets 1.1.17 teach this authoring pattern. Native symbol/footprint and published animation/static checks passed; physical crimp and fit remain unverified. Three raw fan recordings were added, bringing the inventory to 57; the short take is not a complete state cycle.

AIFlow has resumed thermal-vias. Its declared pour boundaries now match accepted board 17. A nine-via D1 candidate passes native DRC (zero errors/opens) and coarse/fine explicit-terminal screens. At 0.1 mm, LOAD_POS peak improves from 48.4 to 46.4 A/mm2; SHUNT_P remains 59.4, still a small margin. Live adoption has not yet completed. Cooling interface, mounting and formal thermal/finish gates remain unresolved. A revised four-hole mounting envelope cleared fitted bodies but collided with TP3 and TP7, so it was not adopted.

Latest accepted board — 2026-10-09, 16:07 UTC

Board 17 contains the verified shunt refinement: zero native DRC errors/opens, exact saved-copper match, and experimental current peaks below 60 A/mm² at both 0.2 and 0.1 mm mesh. The fine-mesh shunt peak is 59.4, a small margin. Formal current/thermal gates and cooling/mounting remain unfinished. See shunt evidence. There are 54 indexed raw takes; many remain unsuitable for the final edit.

Current checkpoint — 2026-10-09, 15:56 UTC

The saved current-path rework passes native DRC with project rules: zero errors and zero opens. Its tracks, vias and filled zones match the checked candidate. The explicit-terminal 0.1 mm diagnostic improves four power paths; SHUNT_P remains at 61.7 A/mm² against a 60 threshold. Ground increases to 43.3 A/mm². A further isolated shunt-via candidate passes DRC and the coarse screen; its fine-mesh comparison is running and it is not adopted. See current-path evidence.

The output-locked STM32 USB bring-up image now includes PA7/TIM2 fan tach capture and stale-history expiry. It compiles to 64,592 bytes of flash and 23,968 bytes of RAM including reserved stack/heap. Host safety/framing/tach tests and 17 Python tests pass. No firmware was flashed; physical USB, fan timing, sensor integration, actuator control and production boot identity remain unverified or unfinished. See build instructions.

The inventory contains 53 raw takes, including static/rejected recordings. The newest usable action candidate shows the actual diode rotation and parallel power-path changes. Final editorial review and the narrated film are unfinished.

AIFlow routing revisit has passed. Current, thermal, cooling/mounting, full component/model review and fabrication release remain incomplete. The board remains a two-layer 3rdPartyFab prototype, with the 5 W bring-up ceiling and no physical qualification.

Historical checkpoints (superseded by the current checkpoint above)

STM32 compile checkpoint — 2026-10-09

The output-locked STM32G0B1KCT6 USB bring-up adapter now builds with pinned TinyUSB/CMSIS/HAL sources and GNU Arm 13.2.1. The link uses 63,108 bytes of flash and 23,912 bytes of RAM including the reserved stack/heap sections. ELF, HEX and BIN artifacts exist locally with hashes. The board-specific initialization keeps PA5 enable LOW and PB3 fault-clear open drain; no Nucleo LED code is linked. No image was flashed. USB enumeration, actual sensors, tach capture, actuator control and reset-fresh boot identity remain unfinished. The example USB identity is lab-only. See build instructions, build evidence, and compiler output.

Thermal-via and protocol checkpoint — 2026-10-09

AIFlow adopted aiflow/run/board-14.kicad_pcb (native SHA-256 b2a4d8321f24af5d3f95f9df6fab570b96abb298b4cc70b3f932037d2fec9f8d). Five vias were added after isolated native DRC: two SHUNT_P thermal vias, two LOAD_POS diode vias and one GND stitch that prevents an isolated ground region. Saved native copper matches the checked candidate; its native DRC has zero errors/opens and fifteen existing library lookup warnings. The thermal-via heuristic still reports D1 6/10, Q1 0/16 and RSH1 2/6; no shortfall was acknowledged.

The experimental two-layer/PTH-corrected Fields binary converged on all six loaded nets and both board-only thermal solves. Three 3 A current-neck flags remain. The board-only model omits the required case-mounted heatsink, so its high temperatures are a failed screen, not a prediction of the intended cooled assembly or a pass. The shared Fields PR remains open.

The portable device protocol now interoperates with the Python control-panel transport. Tests cover boot-wide sequence replay protection, owner/lease rules, bounded parsing, fault/OFF callbacks, and fuzz input. All C host checks and 17 Python tests pass. MCU/HAL/USB deployment and physical timing remain unfinished. The video inventory contains 51 raw takes including rejected/static takes; a new clearly labeled host-simulation clip shows the real compiled C protocol refusing ARM and replay.

Cooling-clearance revision — 2026-10-09

The native board now has relocated current/temperature probes and fan header, with unused copper branches removed. The checked candidate has zero native DRC errors or opens and fifteen existing library lookup warnings; saved native copper matches it. AIFlow adopted aiflow/run/board-13.kicad_pcb. Native 2D and 3D views were inspected. The dashboard shows the current saved review.

All 91 fitted STEP bodies pass a conservative bounding-box screen against the nominal offset sink. This is not full assembly clearance: the SWD header J11 sits beneath the sink and a mating programming plug has not been checked. Programming/service access, clamps, TIM, airflow and thermal acceptance remain unresolved. Thirteen bare probe/contact footprints have no fitted model and remain covered by the separate probe-envelope check.

Native USB revision — 2026-10-09

The saved two-layer board now has 104 footprints, 52 nets, 1,668 track segments and 256 vias. Native KiCad reports zero DRC errors and zero unconnected items. Fifteen library-configuration warnings remain in the validation snapshot; these are not a complete library qualification. U10 is inline near the USB connector; R31/R32 are 0-ohm links, matching the STM32G0B1 internal-termination requirement. The intended 52-net schematic check passes. Unused USB power, fan tach and SWCLK trace ends were removed.

AIFlow adopted this native-saved revision as board-11 and returned to routing to regenerate its dependent proofs. Cooling, current/thermal screening, final model and silkscreen review, firmware integration and fabrication release remain unfinished. The compact R0 working target is 5 W, consistent with the original size/cost priority and initial DUT; 25 W remains an unqualified future option. No hardware has been built or qualified.

There are 42 indexed raw takes and 16 previously reviewed excerpts; two new raw takes show actual USB footprint/copper edits and trace-stub cleanup. The final narrated film is unfinished.

Evidence: USB review, native validation, saved copper parity, recording inventory.

Previous checkpoint

Routed checkpoint — 2026-10-08

The accepted plan has landed in native KiCad: 230 route operations, 1,675 track segments and 257 vias. The saved two-layer board has zero DRC errors and zero unconnected items, with zero warnings in the latest saved-board check. Twelve power-track segments have been widened from 1.2 mm to 1.5 or 2.0 mm; the native saved geometry matches the accepted candidate. It contains 104 footprints and 52 nets. Both ground zones were refilled and their areas remained stable across two native readbacks. The prototype title was saved using a separate DRC-checked native text edit.

A parallel SHUNT_P via and bottom link now reduce the screened peak from 111.5 to 96.2 A/mm² at the same 3 A / 0.2 mm mesh assumptions.

Four local heat-spreading zones and three diode vias have been added and recorded. AIFlow has advanced from routing to thermal-vias; the complete flow has not passed.

This is a routing checkpoint, not a fabrication release. The 5 W bring-up ceiling remains. USB pair/reference review, power-path/current screening, cooling geometry, model qualification, final silk and hardware calibration are still required. No hardware has been assembled. The 25 W target is unvalidated.

The installed Fields 0.6.2 model had a hardcoded four-layer stack and omitted plated through-hole pad barrels. An isolated correction now passes 21 tests and converges at both 0.2 and 0.1 mm meshes. It is submitted as Fields PR 5; the shared installation is unchanged. Four power-path constrictions remain under review. Thermal assembly qualification is still unavailable. See field-screen review. Current PCB and 3D views repaint correctly and have been visually verified.

There are 36 raw video takes and fifteen reviewed excerpts. AIFlow 0.1.70 now automatically opens and recovers the run dashboard; that behavior is also recorded. Two new excerpts show actual heat-spreading copper and diode-via additions; the static thermal-planning take is excluded. A close-up now shows the power and Kelvin-sense paths separately; two short failed attempts are excluded. A fresh native routed-board 3D review now shows verified changing top/oblique/bottom views. Two new recordings ran during actual routing, but pixel checks found stale canvases and they are excluded from the action edit; the fan-fault excerpt is clearly labeled software simulation. The final narrated 4–5 minute film is not complete.

Evidence: saved-board DRC, thermal copper audit, parallel-via review, power-width audit, power-width comparison, native net audit, ground correction, recording inventory.

Earlier checkpoint history

Latest routing work — 2026-10-08

Four sense branches are now saved in native KiCad. The saved board passes native DRC with zero violations and 202 open connections. Bottom GND copper is filled. It remains a two-layer 3rdPartyFab engineering prototype, not ready for fabrication.

The revised placement fixes the initial oversized switching-loop layout. The subsequent bulk route planner reached zero failures, but its native gate rejected the plan for 68 new findings and 14 opens. The bulk plan was not landed. See routing review for evidence and the AIFlow issue 36 handoff.

Real ground-pour and sense-route recordings were saved and added to the shot log. Their planning waits require editing; no final narrated film is ready. The 5 W bring-up ceiling remains; 25 W cooling is unresolved.


Engineering status — 2026-10-08

Current checkpoint: 104 components, 52 nets, two copper layers. Native KiCad DRC: zero violations, 220 unrouted connections. ERC: zero findings; all 52 intended schematic nets match the exported native netlist. AIFlow finds all nine test-plan measurements probe-able after adding TP12 (FAN_TACH) and TP13 (SHUNT_N_SENSE). Final assembled probe clearance remains unverified.

The tach-feedback fan has a reusable component page and simulated GLB motion preview. Portable fan interlocks and the local control-panel prototype exist; MCU/HAL/USB integration and physical measurements do not. See fan feedback, thermal budget correction, and recorded clips. The load remains limited to 5 W for bring-up. The 25 W target is not validated.

Routing, full component/model qualification, cooling assembly, final silk, current/thermal analysis, fabrication outputs and hardware qualification remain unfinished. Do not fabricate this draft.

Earlier checkpoint history

Engineering status — 2026-10-07

Implemented: independent 102-component/52-net connectivity source; hierarchical KiCad schematic; native two-layer molecule board outline with fixed machine pins/contacts and staged components; sourced semiconductor candidates; portable package models; generated nominal Kelvin shunt model; TI-amplifier/approximate-MOSFET transient sensitivity study; portable C load-safety policy and host tests; AI Flow run and raw build clips.

Verified: native KiCad 10.0.5 schematic ERC has zero findings after the Kelvin-ground correction; every intended net matches the native exported schematic netlist. Six current-loop sensitivity cases settle within the selected windows with 1 nF compensation. Safety-core tests pass with compiler warnings treated as errors and address/undefined-behavior sanitizers. Native board and 3D setup views were inspected; they show the outline and machine interfaces, with the remaining components still staged outside the board.

Not complete: manufacturer-level CAD audit, all live inventory counts, mechanical cooling assembly, final mechanical placement, routing, DRC-clean PCB, Fields/current/thermal analysis, fabrication exports, MCU firmware/HAL/USB integration, control-panel dashboard, assembled hardware, calibration and industrial qualification. Do not fabricate from this draft. The 25 W/24 V/3 A envelope is provisional and simultaneous; the first DUT is the 5 V/1 A buck. Firmware policy limits bring-up to 5 W.

The schematic capture attempt failed with an encoder initialization timeout. Other raw clips are available, but the static component setup clip is excluded from the planned action edit. No final narrated demo or YouTube publication exists.

A read-only Bridge inspection unexpectedly reported dismissing an unrelated Remote Desktop dialog. Reported to the owner as adom/kicad-bridge#120. No fix or deployment is verified. Subsequent window inventories use autoDismiss:false.

Placement update: the native candidate now has zero DRC violations, with 218 unrouted connections. Its USB intra-footprint hole-clearance rule and unresolved U2 assembled label location are documented in the placement review.

9 October, 20:54 UTC continuation

AIFlow 0.1.77 is source-published directly, registry-published and locally installed. The actual Native Browser visual/DOM disagreement now classifies as human verification. Its published release page was visually reviewed. This does not prove installation in Colby's session.

Board 18 remains unchanged; live revision rechecked. The dashboard is open at thermal-vias, step 9 of 19. Fields 0.6.2 remains installed, physical-stack/PTH PR #5 remains open, and package heat-path issue #8 remains open. No thermal/finish gate was waived.

The cooling fastener review now checks the actual TO-220 tab thickness and the PPS washer catalog, plus a clearly limited short-sleeve centering sensitivity. No exact toleranced clamp stack is qualified. The stock sink candidate remains provisional.

The output-locked firmware now cross-compiles I2C and ADC diagnostics. Host tests cover actual I2C/ADC adapter code through fake HALs, register faults, sample age, nominal thermistor conversion and existing safety/protocol behavior; 25 Python tests also pass. The current build uses 74,004 bytes flash and 24,192 bytes RAM including reservations. No flash, physical sensor measurement, calibration or enabled load test occurred. Sensor and assembly qualification remain false.

The video inventory is 63 raw takes, including rejected material. The newest static fastener-page recording is excluded from the action edit; its full decode passed and recorder timing warning is retained. This is not 63 finished highlights. The narrated final film remains incomplete.

Coupled package study

Fine-grid package cooling study completed. Full 5.5 W retained; 75.6/51.1 C case at 40 C ambient under supplied still/forced parameters. Thermal remains open. Fields PR #11 submitted for owner review. Clip inventory: 89 raw takes, 33 reviewed excerpts, 29 storyboard candidates.

Review exports and cooling carrier

Native manufacturing review now contains the two-layer Gerbers, drills and placement data. Drill centers/tool sizes and placement coordinates match v85. Stackup reconciliation, complete CAM/DFM and thermal acceptance remain open; these are not released fabrication files.

The carrier study now rotates the fan 45 degrees to separate its mounting holes from sink supports. Nominal body and probe envelopes clear. The current view was recorded; harness, fastener retention and cooling qualification remain unfinished.

Installed fan digital model

The nominal installed harness now joins the rotating fan to J9 through the added Harwin connector. One assembly GLB preserves the actual PCB, carrier, three wires, connector and rotor animation. Native browser checks verify simulated on/off rotation and invalid-telemetry pause; the new 2× clip is reviewed. The route and crimp/cut lengths remain provisional, and no physical RPM or fit is claimed.

The initial dimensioned heatsink draft is separate and incomplete. It does not replace the envelope or establish contact, fastener or airflow performance.