Current-path rework — 9 October 2026
The native-saved candidate was adopted after matching every track/via and the filled copper unions to the offline candidate. Native DRC with project rules reports zero errors and zero opens. D1 was rotated 180 degrees, four power paths gained parallel copper, and I_SET and SHUNT_P_SENSE were rerouted without changing schematic pin/net assignments. The Kelvin sense net remains separate.
A paired 0.1 mm explicit-terminal diagnostic at 3 A gives these peak current densities in A/mm²:
| Net | Before | After |
|---|---|---|
| DUT_POS | 63.1 | 42.0 |
| DUT_FUSED | 96.4 | 43.0 |
| LOAD_POS | 82.9 | 48.4 |
| SHUNT_P | 90.5 | 61.7 |
| GND | 26.9 | 43.3 |
SHUNT_P still exceeds the 60 A/mm² diagnostic threshold. Ground peak and Joule loss increased; ground remains below that threshold. The result is an improvement, not a passed current or thermal gate. The solver is an experimental corrected Fields build with project-specific source/sink mapping, not the deployed shared solver or a hardware qualification. Both mesh runs converged to the unchanged 1e-7 residual criterion.
Evidence: checkpoints/current-rework-mesh-0p1/comparison.json, design/current-rework-live/saved-comparison.json, and checkpoints/current-rework-live/native-drc.json. The saved live board SHA-256 is 347fc37404eff3e81dfb3211f06e3da4fe036657e130fec4f0f64a7e6f494f09.
The actual native landing was recorded in window-1514974-20261009-154300.mp4: 68.2 seconds raw, 11.5 seconds in the automatic action cut. Full decode and contact sheet were reviewed. Crowded labels and disabled fill display limit its presentation quality; final editorial selection is pending.
Next: repair the remaining shunt constriction, repeat current review, and complete the actual case/interface/heatsink/mounting analysis. Cooling, physical validation, manufacturing release, and final demo remain incomplete.
# Current-path rework — 9 October 2026
The native-saved candidate was adopted after matching every track/via and the filled copper unions to the offline candidate. Native DRC with project rules reports zero errors and zero opens. D1 was rotated 180 degrees, four power paths gained parallel copper, and I_SET and SHUNT_P_SENSE were rerouted without changing schematic pin/net assignments. The Kelvin sense net remains separate.
A paired 0.1 mm explicit-terminal diagnostic at 3 A gives these peak current densities in A/mm²:
| Net | Before | After |
| --- | ---: | ---: |
| DUT_POS | 63.1 | 42.0 |
| DUT_FUSED | 96.4 | 43.0 |
| LOAD_POS | 82.9 | 48.4 |
| SHUNT_P | 90.5 | 61.7 |
| GND | 26.9 | 43.3 |
SHUNT_P still exceeds the 60 A/mm² diagnostic threshold. Ground peak and Joule loss increased; ground remains below that threshold. The result is an improvement, not a passed current or thermal gate. The solver is an experimental corrected Fields build with project-specific source/sink mapping, not the deployed shared solver or a hardware qualification. Both mesh runs converged to the unchanged 1e-7 residual criterion.
Evidence: `checkpoints/current-rework-mesh-0p1/comparison.json`, `design/current-rework-live/saved-comparison.json`, and `checkpoints/current-rework-live/native-drc.json`. The saved live board SHA-256 is `347fc37404eff3e81dfb3211f06e3da4fe036657e130fec4f0f64a7e6f494f09`.
The actual native landing was recorded in `window-1514974-20261009-154300.mp4`: 68.2 seconds raw, 11.5 seconds in the automatic action cut. Full decode and contact sheet were reviewed. Crowded labels and disabled fill display limit its presentation quality; final editorial selection is pending.
Next: repair the remaining shunt constriction, repeat current review, and complete the actual case/interface/heatsink/mounting analysis. Cooling, physical validation, manufacturing release, and final demo remain incomplete.