Field-screen result before power widening — 2026-10-08
The initial failures were traced to two source defects: a hardcoded four-layer stack and missing plated through-hole pad barrels. The latter falsely isolated J10's bottom GND pad. With the plated barrels included, the 0.2 mm ground raster has one connected component instead of two. The source correction is in Fields PR 5, superseding PR 4's outdated review snapshot. Twenty-one tests and production check/build pass. The shared Fields installation remains unchanged.
Both 0.2 mm and 0.1 mm electrical screens converge using an explicit 16000-iteration budget and unchanged tolerances. Ground requires 6909 and 13879 iterations respectively. Residuals are recomputed from the actual equations. Total copper loss is 0.237 W / 0.239 W for the original heuristic-terminal screen. This is numerical evidence, not a measured power rating.
| Net | Peak A/mm², 0.2 mm | Peak A/mm², 0.1 mm | Copper loss W, coarse / fine |
|---|---|---|---|
| SHUNT_P | 111.5 | 126.5 | 0.047 / 0.049 |
| DUT_FUSED | 105.8 | 106.3 | 0.042 / 0.042 |
| LOAD_POS | 95.6 | 98.2 | 0.083 / 0.085 |
| DUT_POS | 77.2 | 77.6 | 0.044 / 0.041 |
| GND | 19.8 | 20.3 | 0.02 / 0.021 |
| 5V_AUX | 10.8 | 9.8 | 0.001 / 0.001 |
The shunt-path peak changes about 13.5% with resolution; all four power-neck flags remain. Main traces at those locations are 1.2 mm wide. The displayed “equivalent neck width” is inferred from current density and is not a direct measurement of track width.
A separate project-only diagnostic explicitly injects 3 A through J1.1→F1.1, F1.2→D1.2, D1.1→Q1.2, Q1.3→RSH1.1 and RSH1.4→J2.1. It preserves physical copper and replaces only the terminal-selection list. The assumption is that all main load return exits J2.1; alternate workcell return wiring is not modeled. It converges and confirms the same four constrictions. Explicit terminal results.
The thermal solve is not an assembly prediction: it deposits package watts into the board and omits the MOSFET-to-heatsink heat path and fan airflow. Its extreme temperatures are outside a useful physical interpretation of the intended cooled assembly. It does not qualify cooling, MOSFET SOA, junction temperature or a 25 W rating. The 5 W bring-up policy remains unchanged and is not physical qualification.
The current-only viewer was opened and visually inspected with exactly F.Cu/B.Cu controls. Native CAD PCB and 3D views now render, and a fresh routed-board review clip was published. Twelve wider power segments have since passed native DRC and landed in the canonical saved board. The table above describes the preserved pre-widening board. See the before/after electrical comparison for the new checkpoint.
Earlier failure evidence
Two-layer field-screen review
The saved routed PCB is two-layer. Fields 0.6.2 incorrectly creates four copper layers and assumes three dielectric intervals; that installed-version run was stopped and cannot support this design.
An isolated source build corrects the layer model and viewer, retains physical hidden/empty Fusion layers, and rejects unsupported stacks and blind/buried vias. Eighteen tests, production check/build, JavaScript syntax check and contextual-diff preflight pass. Fields PR 4 awaits owner review; no shared installation was replaced. Source, binary and input identities are recorded in provenance.
The explicit nominal assumption is 35 µm copper on both sides with a 1.53 mm dielectric interval, totaling 1.6 mm. This is not a measured manufacturing stack. The original 3 A power-net loads and 25 W Q1 target were retained; the separate 5 W bring-up ceiling was not raised.
Rejected 0.2 mm mesh
Five loaded nets converged, but GND exhausted 6000 iterations with residual 316.3. The first experimental run checked only thermal convergence and incorrectly emitted 599.856 W of ground Joule loss and extreme temperatures. Those outputs are invalid and retained only as reproduction evidence; they are not predictions of board temperature or power dissipation.
The revised source checks every DC residual before publishing a summary. Repeating the actual board at 0.2 mm now returns an explicit nonconvergence error and emits no fields.json. Guard log.
At 0.1 mm, GND again exhausted 6000 iterations (residual approximately 3.8). The task-owned run was stopped after this electrical failure, before completing thermal analysis. No accepted summary exists at either mesh; this establishes an unresolved solver/raster limitation, not a physical open in the DRC-clean board. Fine-mesh log. Neither a converged field plot nor native DRC would establish MOSFET SOA, junction temperature, the external heatsink/fan assembly, or hardware shutdown performance. The board is not released for fabrication.
# Field-screen result before power widening — 2026-10-08
The initial failures were traced to two source defects: a hardcoded four-layer stack and missing plated through-hole pad barrels. The latter falsely isolated J10's bottom GND pad. With the plated barrels included, the 0.2 mm ground raster has one connected component instead of two. The source correction is in [Fields PR 5](https://wiki.adom.inc/adom/adom-fields/prs/5), superseding PR 4's outdated review snapshot. Twenty-one tests and production check/build pass. The shared Fields installation remains unchanged.
Both 0.2 mm and 0.1 mm electrical screens converge using an explicit 16000-iteration budget and unchanged tolerances. Ground requires 6909 and 13879 iterations respectively. Residuals are recomputed from the actual equations. Total copper loss is 0.237 W / 0.239 W for the original heuristic-terminal screen. This is numerical evidence, not a measured power rating.
| Net | Peak A/mm², 0.2 mm | Peak A/mm², 0.1 mm | Copper loss W, coarse / fine |
|---|---:|---:|---:|
| SHUNT_P | 111.5 | 126.5 | 0.047 / 0.049 |
| DUT_FUSED | 105.8 | 106.3 | 0.042 / 0.042 |
| LOAD_POS | 95.6 | 98.2 | 0.083 / 0.085 |
| DUT_POS | 77.2 | 77.6 | 0.044 / 0.041 |
| GND | 19.8 | 20.3 | 0.02 / 0.021 |
| 5V_AUX | 10.8 | 9.8 | 0.001 / 0.001 |
The shunt-path peak changes about 13.5% with resolution; all four power-neck flags remain. Main traces at those locations are 1.2 mm wide. The displayed “equivalent neck width” is inferred from current density and is not a direct measurement of track width.
A separate project-only diagnostic explicitly injects 3 A through J1.1→F1.1, F1.2→D1.2, D1.1→Q1.2, Q1.3→RSH1.1 and RSH1.4→J2.1. It preserves physical copper and replaces only the terminal-selection list. The assumption is that all main load return exits J2.1; alternate workcell return wiring is not modeled. It converges and confirms the same four constrictions. [Explicit terminal results](../design/power-paths-explicit-0p2.json).
The thermal solve is **not an assembly prediction**: it deposits package watts into the board and omits the MOSFET-to-heatsink heat path and fan airflow. Its extreme temperatures are outside a useful physical interpretation of the intended cooled assembly. It does not qualify cooling, MOSFET SOA, junction temperature or a 25 W rating. The 5 W bring-up policy remains unchanged and is not physical qualification.
The current-only viewer was opened and visually inspected with exactly F.Cu/B.Cu controls. Native CAD PCB and 3D views now render, and a fresh routed-board review clip was published. Twelve wider power segments have since passed native DRC and landed in the canonical saved board. The table above describes the preserved pre-widening board. See the [before/after electrical comparison](power-width-review.md) for the new checkpoint.
## Earlier failure evidence
# Two-layer field-screen review
The saved routed PCB is two-layer. Fields 0.6.2 incorrectly creates four copper layers and assumes three dielectric intervals; that installed-version run was stopped and cannot support this design.
An isolated source build corrects the layer model and viewer, retains physical hidden/empty Fusion layers, and rejects unsupported stacks and blind/buried vias. Eighteen tests, production check/build, JavaScript syntax check and contextual-diff preflight pass. [Fields PR 4](https://wiki.adom.inc/adom/adom-fields/prs/4) awaits owner review; no shared installation was replaced. Source, binary and input identities are recorded in [provenance](../design/fields-two-layer-provenance.json).
The explicit nominal assumption is 35 µm copper on both sides with a 1.53 mm dielectric interval, totaling 1.6 mm. This is not a measured manufacturing stack. The original 3 A power-net loads and 25 W Q1 target were retained; the separate 5 W bring-up ceiling was not raised.
## Rejected 0.2 mm mesh
Five loaded nets converged, but GND exhausted 6000 iterations with residual 316.3. The first experimental run checked only thermal convergence and incorrectly emitted 599.856 W of ground Joule loss and extreme temperatures. Those outputs are invalid and retained only as reproduction evidence; they are not predictions of board temperature or power dissipation.
The revised source checks every DC residual before publishing a summary. Repeating the actual board at 0.2 mm now returns an explicit nonconvergence error and emits no fields.json. [Guard log](../design/fields-two-layer-guard-check.log).
At 0.1 mm, GND again exhausted 6000 iterations (residual approximately 3.8). The task-owned run was stopped after this electrical failure, before completing thermal analysis. No accepted summary exists at either mesh; this establishes an unresolved solver/raster limitation, not a physical open in the DRC-clean board. [Fine-mesh log](../design/fields-two-layer-fine.log). Neither a converged field plot nor native DRC would establish MOSFET SOA, junction temperature, the external heatsink/fan assembly, or hardware shutdown performance. The board is not released for fabrication.