526eaf9
Native pour review
AIFlow reconciled seven existing copper zones using their original successful creation receipts and exact native IDs. The ownership guard initially refused them because those IDs were absent from the run manifest. Ownership was recovered from receipts, never inferred from names.
The complete native transaction preserved all seven copper zones and added the two planned Kelvin sense pad copper-pour keepouts at U4. It removed no zones. Native DRC after candidate refill reports zero errors, zero unconnected items and 15 inherited library lookup warnings. The native editor was saved and the board and project rules pulled together. See design/step10-pour-review.json for IDs, saved-file hash and measured filled areas.
This closes the native pour operation, not thermal qualification. Q1 still requires a verified case/interface/heatsink/fan assembly; the current and thermal Fields gates must use this saved board. The generic via-count exceptions and their engineering limits are in via planning review.
Two raw recordings were captured. Their contact sheets were reviewed; the longer successful transaction fully decodes. Most footage is static and will be excluded from the final action edit. The inventory contains 67 raw takes, including rejected takes, not 65 finished demo clips.
AIFlow subsequently recorded the rounded-outline proof and entered current analysis (12/19, 11 done). The repeated pour command unexpectedly regenerated the two keepout UUIDs despite identical complete zone definitions and filled areas; see design/step10-repeat-review.json. Do not replay the operation again.
The new 0.1 mm diagnostic converged on all five explicit main power paths: DUT_POS 42.0, DUT_FUSED 43.0, LOAD_POS 46.4, SHUNT_P 59.4 and GND 43.3 A/mm². All are below its 60 A/mm² threshold, with little shunt margin. It is an experimental electrical screen, not the formal current gate or thermal qualification. The formal gate remains failed pending terminal-aware heuristic handling and supported same-input Fields evidence.
# Native pour review
AIFlow reconciled seven existing copper zones using their original successful creation receipts and exact native IDs. The ownership guard initially refused them because those IDs were absent from the run manifest. Ownership was recovered from receipts, never inferred from names.
The complete native transaction preserved all seven copper zones and added the two planned Kelvin sense pad copper-pour keepouts at U4. It removed no zones. Native DRC after candidate refill reports zero errors, zero unconnected items and 15 inherited library lookup warnings. The native editor was saved and the board and project rules pulled together. See `design/step10-pour-review.json` for IDs, saved-file hash and measured filled areas.
This closes the native pour operation, not thermal qualification. Q1 still requires a verified case/interface/heatsink/fan assembly; the current and thermal Fields gates must use this saved board. The generic via-count exceptions and their engineering limits are in [via planning review](via-planning-review.md).
Two raw recordings were captured. Their contact sheets were reviewed; the longer successful transaction fully decodes. Most footage is static and will be excluded from the final action edit. The inventory contains 67 raw takes, including rejected takes, not 65 finished demo clips.
AIFlow subsequently recorded the rounded-outline proof and entered current analysis (12/19, 11 done). The repeated pour command unexpectedly regenerated the two keepout UUIDs despite identical complete zone definitions and filled areas; see `design/step10-repeat-review.json`. Do not replay the operation again.
The new 0.1 mm diagnostic converged on all five explicit main power paths: DUT_POS 42.0, DUT_FUSED 43.0, LOAD_POS 46.4, SHUNT_P 59.4 and GND 43.3 A/mm². All are below its 60 A/mm² threshold, with little shunt margin. It is an experimental electrical screen, not the formal current gate or thermal qualification. The formal gate remains failed pending terminal-aware heuristic handling and supported same-input Fields evidence.