Board 18 via-planning decision

This closes only the geometric via-planning review. It does not approve the full thermal design or fabrication release. The board, loss assumptions and temperature limits are unchanged.

D1 retains 10 qualifying vias, meeting its target. Q1's generic 16-via target does not model its proposed TO-220 case/interface/external-heatsink path; its tab is above the board, and drain-pin vias cannot establish that cooling path. Record this as a via-count exception while retaining Q1's 5 W loss and unresolved package cooling in the later thermal gate.

RSH1 retains three locally qualifying vias and the verified ground stitch, preserving its Kelvin connections. AIFlow's target function clamps every hot part to at least six vias. A conservative barrel sensitivity using three 0.3 mm holes through 1.6 mm FR4 gives approximately 13.9 C at 18 um assumed plating and 9.8 C at 25 um, with all 0.18 W routed through the barrels. Both are below the planner's 17.5 C interlayer allocation (half its 35 C budget). This is not a resistor-to-ambient result: equal sharing, ideal local copper and assumed plating require downstream review. No manufacturer minimum via count was supplied by this heuristic.

The native saved board has zero DRC errors and zero opens; the live board revision still matches the recorded board-18 checkpoint. No geometry is changed by these decisions. Later current and thermal gates still require a supported same-input Fields analysis, and the Q1 cooling assembly remains unresolved. A via-count acknowledgement is not a thermal-analysis pass.

Machine-readable calculation and input hashes. Reproduce with python3 tools/review_step9_scope.py.