main
John Lauer
Resolve board18 via-planning counts separately from mandatory thermal qualification
bc54ad2
{
"scope": "via-planning-review-only",
"boardSha256": "8d6cd24149f7de061f125bf45a26b50ca5b70a6b01c62b96dc3cf92187a531f1",
"specSha256": "4fa060d03263bc9ed43657386d80b9261e0e523e7e2e6762867d4ec80275bd60",
"D1": {
"decision": "retain",
"qualifyingVias": 10,
"heuristicTarget": 10
},
"Q1": {
"decision": "case-heatsink-path; PCB-via heuristic not applicable as primary cooling design",
"qualifyingVias": 0,
"heuristicTarget": 16,
"thermalAcceptance": false,
"reason": "TO-220 tab is above PCB; primary proposed heat path is case/interface/external sink, not the drain pin and PCB vias. Additional drain-pin vias do not establish that path."
},
"RSH1": {
"decision": "retain three locally qualifying vias, preserve Kelvin isolation and existing GND stitch",
"qualifyingVias": 3,
"heuristicTarget": 6,
"watts": 0.18,
"plannerRiseBudgetC": 35,
"plannerViaAllocationC": 17.5,
"sensitivity": [
{
"platingUmAssumed": 18,
"threeViaThetaKPerW": 77.0350733894902,
"barrelDropAt018W_C": 13.866313210108235
},
{
"platingUmAssumed": 25,
"threeViaThetaKPerW": 54.27061662540823,
"barrelDropAt018W_C": 9.768710992573482
}
],
"assumptions": "Three 0.3mm finished holes through 1.6mm board, copper conductivity385W/mK, 18/25um assumed plating. Larger actual vias receive no additional credit. Equal sharing and ideal local copper assumed.",
"limitations": "Barrel-only interlayer drop, not resistor-to-ambient rise. Plating is a sensitivity assumption, not verified fab capability. Copper necks/spreading/package/airflow remain in later current/thermal analysis."
},
"downstreamRequirements": [
"Native pour connectivity and current review",
"Same-input supported Fields solve",
"Q1 package/interface/sink/airflow design and thermal screen",
"Physical assembly/fault qualification before enabling production load"
],
"thermalPass": false,
"finishPass": false
}