main
John Lauer Resolve board18 via-planning counts separately from mandatory thermal qualification bc54ad2
{
  "scope": "via-planning-review-only",
  "boardSha256": "8d6cd24149f7de061f125bf45a26b50ca5b70a6b01c62b96dc3cf92187a531f1",
  "specSha256": "4fa060d03263bc9ed43657386d80b9261e0e523e7e2e6762867d4ec80275bd60",
  "D1": {
    "decision": "retain",
    "qualifyingVias": 10,
    "heuristicTarget": 10
  },
  "Q1": {
    "decision": "case-heatsink-path; PCB-via heuristic not applicable as primary cooling design",
    "qualifyingVias": 0,
    "heuristicTarget": 16,
    "thermalAcceptance": false,
    "reason": "TO-220 tab is above PCB; primary proposed heat path is case/interface/external sink, not the drain pin and PCB vias. Additional drain-pin vias do not establish that path."
  },
  "RSH1": {
    "decision": "retain three locally qualifying vias, preserve Kelvin isolation and existing GND stitch",
    "qualifyingVias": 3,
    "heuristicTarget": 6,
    "watts": 0.18,
    "plannerRiseBudgetC": 35,
    "plannerViaAllocationC": 17.5,
    "sensitivity": [
      {
        "platingUmAssumed": 18,
        "threeViaThetaKPerW": 77.0350733894902,
        "barrelDropAt018W_C": 13.866313210108235
      },
      {
        "platingUmAssumed": 25,
        "threeViaThetaKPerW": 54.27061662540823,
        "barrelDropAt018W_C": 9.768710992573482
      }
    ],
    "assumptions": "Three 0.3mm finished holes through 1.6mm board, copper conductivity385W/mK, 18/25um assumed plating. Larger actual vias receive no additional credit. Equal sharing and ideal local copper assumed.",
    "limitations": "Barrel-only interlayer drop, not resistor-to-ambient rise. Plating is a sensitivity assumption, not verified fab capability. Copper necks/spreading/package/airflow remain in later current/thermal analysis."
  },
  "downstreamRequirements": [
    "Native pour connectivity and current review",
    "Same-input supported Fields solve",
    "Q1 package/interface/sink/airflow design and thermal screen",
    "Physical assembly/fault qualification before enabling production load"
  ],
  "thermalPass": false,
  "finishPass": false
}