a330ddf
Shunt current-path refinement
On 9 October 2026, the back-layer source spread was expanded and one SHUNT_P via was added at (136.9, 86.65) mm, 0.6 mm diameter / 0.3 mm drill. Native DRC with project rules passed with zero errors and zero opens. Saved tracks/vias and per-net/layer filled copper unions exactly match the independently checked candidate. The saved native SHA-256 is 653e54e711552eb2f16b6d01cd144fd82645a52c30ff11e39699b760402af51a; AIFlow adopted it as board 17.
At 3 A per path, the explicit-terminal diagnostic reports SHUNT_P peaks of 57.9 A/mm² at 0.2 mm mesh and 59.4 A/mm² at 0.1 mm. The paired fine-mesh baseline was 61.7 A/mm². Other fine-mesh net peaks remain unchanged: DUT_POS 42.0, DUT_FUSED 43.0, LOAD_POS 48.4, and GND 43.3 A/mm². All DC residuals satisfy the unchanged 1e-7 criterion.
The margin below the 60 A/mm² diagnostic threshold is small and mesh-dependent. This is an experimental solver screen, not physical current qualification, a temperature prediction, or a passed formal AIFlow thermal/current gate. The shared Fields correction is still a separate release dependency. Case cooling and manufacturing/assembly validation remain incomplete.
Earlier experiments are retained: expanding only the back source region left a resistor-side peak; enlarging the front shunt region increased its coarse peak to 63.1 A/mm² and was rejected. The final candidate uses the back expansion and a verified interlayer connection, without that front expansion.
Evidence:
checkpoints/shunt-mesh-0p1/comparison.jsoncheckpoints/shunt-source-spread-v3/current-0p2.jsondesign/shunt-final-live/saved-comparison.jsoncheckpoints/shunt-final-live/native-drc.json
Native recording window-1514974-20261009-160603.mp4 covers the real landing. It passed decode review, but the automatic action cut is only 1.5 seconds and the subtle edit is difficult to see through the crowded labels. Do not present the whole static interval as action footage.
# Shunt current-path refinement
On 9 October 2026, the back-layer source spread was expanded and one SHUNT_P via was added at (136.9, 86.65) mm, 0.6 mm diameter / 0.3 mm drill. Native DRC with project rules passed with zero errors and zero opens. Saved tracks/vias and per-net/layer filled copper unions exactly match the independently checked candidate. The saved native SHA-256 is `653e54e711552eb2f16b6d01cd144fd82645a52c30ff11e39699b760402af51a`; AIFlow adopted it as board 17.
At 3 A per path, the explicit-terminal diagnostic reports SHUNT_P peaks of 57.9 A/mm² at 0.2 mm mesh and 59.4 A/mm² at 0.1 mm. The paired fine-mesh baseline was 61.7 A/mm². Other fine-mesh net peaks remain unchanged: DUT_POS 42.0, DUT_FUSED 43.0, LOAD_POS 48.4, and GND 43.3 A/mm². All DC residuals satisfy the unchanged 1e-7 criterion.
The margin below the 60 A/mm² diagnostic threshold is small and mesh-dependent. This is an experimental solver screen, not physical current qualification, a temperature prediction, or a passed formal AIFlow thermal/current gate. The shared Fields correction is still a separate release dependency. Case cooling and manufacturing/assembly validation remain incomplete.
Earlier experiments are retained: expanding only the back source region left a resistor-side peak; enlarging the front shunt region increased its coarse peak to 63.1 A/mm² and was rejected. The final candidate uses the back expansion and a verified interlayer connection, without that front expansion.
Evidence:
- `checkpoints/shunt-mesh-0p1/comparison.json`
- `checkpoints/shunt-source-spread-v3/current-0p2.json`
- `design/shunt-final-live/saved-comparison.json`
- `checkpoints/shunt-final-live/native-drc.json`
Native recording `window-1514974-20261009-160603.mp4` covers the real landing. It passed decode review, but the automatic action cut is only 1.5 seconds and the subtle edit is difficult to see through the crowded labels. Do not present the whole static interval as action footage.