0dc7a50
Current R0 basis — 2026-10-09
Proceed with the compact 5 W prototype target for the initial 5 V/1 A DUT. The earlier 25 W envelope was an assistant assumption and is now a future option. The 55 C trip and 40 C ambient screening assumptions remain unchanged. This choice does not establish an operating rating or waive the actual cooling checks.
Thermal budget correction — 2026-10-08
The 25 W envelope is a design target, not an established continuous rating. The initial calculation assumed a 75 °C MOSFET case while the portable firmware trips at 55 °C. Those assumptions were inconsistent. The calculation now uses 55 °C as an upper ceiling; normal operation must remain below it with allowance for tolerances, sensor lag and temperature gradients.
At the assumed 40 °C ambient and 0.5 °C/W case-to-sink interface, putting all 25 W in the MOSFET leaves only (55−40)/25−0.5 = 0.1 °C/W for sink-to-air resistance, before operating margin. The candidate ATS sink's best listed 0.8 °C/W condition therefore does not establish 25 W operation under this policy, even before installed airflow and local spreading losses are considered.
At the retained 5 W bring-up ceiling, the same calculation allows 2.5 °C/W before margin. This is a plausible test target, not a qualification. Test the actual fan, duct, mounting, interface and sensor placement; monitor case temperature and verify independent shutdown. Fan free-air flow and a valid tachometer signal do not establish installed cooling performance.
Do not raise shutdown thresholds simply to obtain a 25 W label. Resolve the larger cooling assembly or deliberately revise the operating envelope after measured validation. The fan/heatsink stack and its location relative to probing travel remain unresolved. Keep it out of the probe envelope until a checked mechanical assembly proves clearance.
Lower-height candidates screened on 2026-10-08
No BOM substitution is approved by this screen. Retain the tach-feedback fan requirement.
The ATS-CPX050050010-121-C1-R0 manufacturer sheet specifies a 50 × 50 × 10 mm sink, 43 mm mounting-hole pitch, and no included TIM or mounting hardware. Listed ducted resistance is 2.3 K/W at 400 LFM and 1.8 K/W at 700 LFM. With the assumed 0.5 K/W interface, 5 W would produce calculated case rises of 14 K and 11.5 K respectively. These are application-dependent screening figures. A fan mounted above the fins does not establish the datasheet's ducted flow condition; an engineered duct, measured operating airflow, spreading/contact review and temperature test are required. It does not establish the 25 W target.
The ATS-X51450D-C1-R0 sheet gives a 9.5 mm high BGA sink with 45 mm component dimensions and a 61.48 mm dimension in its assembly drawing. Its superGRIP attachment is intended for a BGA package, not the load MOSFET. Do not treat the nominal 45 mm designation as the complete assembly envelope or use the BGA attachment unmodified.
A shorter sink can improve the height budget, but neither candidate resolves the mechanical mounting, fan operating point, hot-spot sensing or continuous-power qualification by itself.
Interface source review — 2026-10-09
The IXTP15N50L2 manufacturer sheet lists junction-to-case resistance 0.42 K/W and TO-220 case-to-sink 0.50 K/W. The latter does not establish the resistance of an added electrical isolator. The drain tab must remain isolated from a touchable sink. A selected isolator, both contact interfaces, spreading and mounting force need their own budget.
The Boyd accessory catalog, page 101 provides TO-220 alumina washer drawings, but its listed 1.57–1.78 mm thicknesses do not match the nominal 0.2 mm interface clearance study. These are research alternatives, not selected BOM items. Do not adopt distributor conductivity figures at elevated temperature as room-temperature design data.
Insulating interface screen, 9 October
Henkel's SIL PAD TSP K1300 technical sheet specifies nominal 0.15 mm thickness and typical flat-plate resistance of 0.2 C-in2/W. For an illustrative 100 mm2 contact area, converting that area-normalized figure gives about 1.29 K/W, before application-specific differences. It therefore cannot justify the previous 0.5 K/W interface assumption. Actual TO-220 effective contact area, clamp pressure, spreading and tolerances require review. This is an excluded assumption, not a selected or qualified part.
The MOSFET datasheet's 1.13 N m mounting-torque limit is a maximum rating, not a recommended assembly torque or proof of isolator pressure. Do not use it as a crimp/clamp procedure. The ceramic alternative still needs an unambiguous drawing, contact-stack specification and assembly qualification.
# Current R0 basis — 2026-10-09
Proceed with the compact 5 W prototype target for the initial 5 V/1 A DUT. The earlier 25 W envelope was an assistant assumption and is now a future option. The 55 C trip and 40 C ambient screening assumptions remain unchanged. This choice does not establish an operating rating or waive the actual cooling checks.
# Thermal budget correction — 2026-10-08
The 25 W envelope is a design target, not an established continuous rating. The initial calculation assumed a 75 °C MOSFET case while the portable firmware trips at 55 °C. Those assumptions were inconsistent. The calculation now uses 55 °C as an upper ceiling; normal operation must remain below it with allowance for tolerances, sensor lag and temperature gradients.
At the assumed 40 °C ambient and 0.5 °C/W case-to-sink interface, putting all 25 W in the MOSFET leaves only (55−40)/25−0.5 = **0.1 °C/W** for sink-to-air resistance, before operating margin. The candidate ATS sink's best listed 0.8 °C/W condition therefore does not establish 25 W operation under this policy, even before installed airflow and local spreading losses are considered.
At the retained 5 W bring-up ceiling, the same calculation allows 2.5 °C/W before margin. This is a plausible test target, not a qualification. Test the actual fan, duct, mounting, interface and sensor placement; monitor case temperature and verify independent shutdown. Fan free-air flow and a valid tachometer signal do not establish installed cooling performance.
Do not raise shutdown thresholds simply to obtain a 25 W label. Resolve the larger cooling assembly or deliberately revise the operating envelope after measured validation. The fan/heatsink stack and its location relative to probing travel remain unresolved. Keep it out of the probe envelope until a checked mechanical assembly proves clearance.
## Lower-height candidates screened on 2026-10-08
No BOM substitution is approved by this screen. Retain the tach-feedback fan requirement.
The [ATS-CPX050050010-121-C1-R0 manufacturer sheet](https://www.qats.com/DataSheet/ATS-CPX050050010-121-C1-R0) specifies a 50 × 50 × 10 mm sink, 43 mm mounting-hole pitch, and no included TIM or mounting hardware. Listed ducted resistance is 2.3 K/W at 400 LFM and 1.8 K/W at 700 LFM. With the assumed 0.5 K/W interface, 5 W would produce calculated case rises of 14 K and 11.5 K respectively. These are application-dependent screening figures. A fan mounted above the fins does not establish the datasheet's ducted flow condition; an engineered duct, measured operating airflow, spreading/contact review and temperature test are required. It does not establish the 25 W target.
The [ATS-X51450D-C1-R0 sheet](https://www.qats.com/DataSheet/ATS-X51450D-C1-R0) gives a 9.5 mm high BGA sink with 45 mm component dimensions and a 61.48 mm dimension in its assembly drawing. Its superGRIP attachment is intended for a BGA package, not the load MOSFET. Do not treat the nominal 45 mm designation as the complete assembly envelope or use the BGA attachment unmodified.
A shorter sink can improve the height budget, but neither candidate resolves the mechanical mounting, fan operating point, hot-spot sensing or continuous-power qualification by itself.
## Interface source review — 2026-10-09
The [IXTP15N50L2 manufacturer sheet](https://www.littelfuse.com/~/media/electronics/datasheets/discrete_mosfets/littelfuse_discrete_mosfets_n-channel_linear_ixt_15n50_datasheet.pdf.pdf) lists junction-to-case resistance 0.42 K/W and TO-220 case-to-sink 0.50 K/W. The latter does not establish the resistance of an added electrical isolator. The drain tab must remain isolated from a touchable sink. A selected isolator, both contact interfaces, spreading and mounting force need their own budget.
The [Boyd accessory catalog, page 101](https://info.boydcorp.com/hubfs/Thermal/Air-Cooling/Boyd-Board-Level-Heatsinks-Catalog.pdf) provides TO-220 alumina washer drawings, but its listed 1.57–1.78 mm thicknesses do not match the nominal 0.2 mm interface clearance study. These are research alternatives, not selected BOM items. Do not adopt distributor conductivity figures at elevated temperature as room-temperature design data.
## Insulating interface screen, 9 October
Henkel's [SIL PAD TSP K1300 technical sheet](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-K1300-en_GL.pdf) specifies nominal 0.15 mm thickness and typical flat-plate resistance of 0.2 C-in2/W. For an illustrative 100 mm2 contact area, converting that area-normalized figure gives about 1.29 K/W, before application-specific differences. It therefore cannot justify the previous 0.5 K/W interface assumption. Actual TO-220 effective contact area, clamp pressure, spreading and tolerances require review. This is an excluded assumption, not a selected or qualified part.
The MOSFET datasheet's 1.13 N m mounting-torque limit is a maximum rating, not a recommended assembly torque or proof of isolator pressure. Do not use it as a crimp/clamp procedure. The ceramic alternative still needs an unambiguous drawing, contact-stack specification and assembly qualification.