Package cooling sensitivity, Board32
The refreshed Board32 study routes Q1's complete 5.5 W through separate junction, case and sink nodes and three explicit physical-pad links. It retains D1/RSH1 heat and PCB Joule losses. This is an unqualified parameter study, not a replacement for the formal thermal gate.
At 40 °C ambient, the 0.1 mm run gives Q1 case temperatures of 75.6 °C still air and 51.1 °C with assumed forced cooling. The junction is 77.9/53.4 °C. Full-power still air exceeds the 55 °C case ceiling. The 0.2 mm sensitivity runs vary each case-to-pad resistance from 10 to 1000 K/W; the forced-case result stays near 51.1 °C. This does not remove uncertainty in installed airflow or interface pressure.
Inputs: junction-to-case 0.42 K/W; case-to-sink 0.5273 K/W, including assumed spreading; catalog-condition sink-to-air values 6/1.5 K/W. The latter forced rating is at 400 LFM, which the installed fan/duct has not demonstrated. Lead resistances are explicitly assumed. The maximum package energy imbalance in the fine run is below 3 nanowatts; numerical balance is not physical model validation.
Board32 summary, fine report, fine input. The earlier sensitivity sweep and earlier review clip remain historical; they are not Board32 footage.
The earlier tools/package_cooling_review.py targets the historical v85 sensitivity results. Board32 uses the input-bound results linked above; do not relabel the old plot as a new solve.
The solver is a private combined build containing the pending actual-layer/physical-terminal stack plus new package nodes. Fields PR #11 offers the package feature against Fields 0.7.7: 20 tests, production check, release build, analytical CLI fixture and isolated viewer inspection pass. Owner review, merge and deployment remain separate; the shared runtime was not replaced.
The PCB remains exactly ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3. Formal current passes. Thermal remains open until the physical interface/support/airflow and fault behavior are justified. No manufacturing release or hardware qualification is claimed.
# Package cooling sensitivity, Board32
The refreshed Board32 study routes Q1's complete 5.5 W through separate junction, case and sink nodes and three explicit physical-pad links. It retains D1/RSH1 heat and PCB Joule losses. This is an **unqualified parameter study**, not a replacement for the formal thermal gate.
At 40 °C ambient, the 0.1 mm run gives Q1 case temperatures of **75.6 °C still air** and **51.1 °C with assumed forced cooling**. The junction is 77.9/53.4 °C. Full-power still air exceeds the 55 °C case ceiling. The 0.2 mm sensitivity runs vary each case-to-pad resistance from 10 to 1000 K/W; the forced-case result stays near 51.1 °C. This does not remove uncertainty in installed airflow or interface pressure.
Inputs: junction-to-case 0.42 K/W; case-to-sink 0.5273 K/W, including assumed spreading; catalog-condition sink-to-air values 6/1.5 K/W. The latter forced rating is at 400 LFM, which the installed fan/duct has not demonstrated. Lead resistances are explicitly assumed. The maximum package energy imbalance in the fine run is below 3 nanowatts; numerical balance is not physical model validation.
[Board32 summary](../checkpoints/board32-package-cooling/summary.json), [fine report](../checkpoints/board32-package-cooling/full-0p1/fields.json), [fine input](../checkpoints/board32-package-cooling/spec-unqualified.json). The [earlier sensitivity sweep](../checkpoints/package-cooling-v85/summary.json) and [earlier review clip](clips/package-cooling-review.mp4) remain historical; they are not Board32 footage.
The earlier `tools/package_cooling_review.py` targets the historical v85 sensitivity results. Board32 uses the input-bound results linked above; do not relabel the old plot as a new solve.
The solver is a private combined build containing the pending actual-layer/physical-terminal stack plus new package nodes. [Fields PR #11](https://wiki.adom.inc/adom/adom-fields/prs/11) offers the package feature against Fields 0.7.7: 20 tests, production check, release build, analytical CLI fixture and isolated viewer inspection pass. Owner review, merge and deployment remain separate; the shared runtime was not replaced.