main
John Lauer aiflow run source-unplaced-codex-astra-20260914-0314: finish 54d9188 22d ago

ESC run validation

Source prompt: 2026-09-14T03:14:00.700Z. Target: ConfRoomROG. Engine: Codex (Astra). AI Flow: 0.1.5.

Fresh input: 149 footprints, 122 parked. Final: all 149 placed, all 27 fixed interfaces unchanged, 461 pads preserved, 4042 segments, 444 vias, 57 zones.

Final native board SHA-256: 7bb6d4f4cd22d52dd99c83548c2cbaa09e7ec97f5173a44d42a3e17f895bc233.

Native and saved-file DRC: zero unconnected, zero new errors against the 13 inherited errors (7 U2 clearance, 6 MOSFET malformed courtyards). Saved-file warnings remain: 149 missing footprint-library configuration warnings and 23 silkscreen-over-copper warnings. The added via hole-spacing warning was repaired and is absent in the final result.

Current and thermal checks pass at the unchanged supplied loads and dissipation. These are AI Flow 0.1 heuristic estimates, not physical load testing, measured temperatures, or validated filled-copper cross-section analysis. The current checker widest-track defect is issue 2; a supplemental check uses the actual 0.2 mm minimum small-rail width and estimates 4.04 C rise at 0.5 A, below the 10 C limit.

Thermal rework expanded connected phase-B copper to about 317 mm2, lowering Q4 estimated rise from 63 C to 49 C. Worst final estimate: Q6, 52.5 C rise against 60 C budget.

The video preserves every recorded step visit in ledger order at 10x. Short analysis/finish clips include a labeled final-frame reading hold. Setup before the first recording and video preparation after capture remain charged to the run clock.

Files

Givebacks