7007e93
Compact R11 — assumed cooling assembly and prototype package
The user authorized geometry, interface and fan assumptions to advance the prototype. This revision adds a direct Q1 insulation stack, side fan, duct, carrier, fastener envelopes, sensor routing and mating-plug reservations. It is a fit study, not a manufacturing or thermal release. The 5 W command cap and output lock remain.
The PCB is 72 × 72 mm with large pins at 64 mm spacing. The added cooling assembly occupies an 83.75 × 76.25 × 56.4 mm envelope; total installed height must also include the downward machine pins. This is a compact-board study, not a claim that the whole molecule occupies only the PCB footprint.

This silent 18-second assembly review is new footage, separate from the approved narrated film. Fan motion is simulated.
Reviews and files
Raw internal intersections and explicit contact classification
Fused fit-part manifest: carrier, duct and fan flange each export as one connected solid, with STEP and STL companions.
Native PCB fabrication package: two-layer 1 oz 3rdPartyFab review files, not an order.
Firmware review: compiled output-locked build, 25 kHz assumed bench PWM, no flash.
The contact review found and corrected wafer/sensor overlap, support/wire crossings, collar hardware clearance and harness spacing. Raw results remain available. Thread and connection overlaps are explicitly classified, not silently removed. This does not verify tolerances, strength, material creep, wire bend radius, latch insertion or clamp pressure.
Sink hold-down and fan-flange retention now have explicit assumed hardware. Their strength, thread engagement and manufactured fit are unverified. Exact manufacturer dimensions and measured performance can replace assumptions later. The original thermal failure remains visible; neither a valid GLB nor an interference-free nominal model proves cooling capacity.
The sink is translated 2 mm inward relative to the earlier fit study so its mounting ear clears the large scaffold pin. The latest access revision also moves the cooling group 7 mm toward the front; a sink-side support avoids the test corridor. Ear profile and the 45 mm diagonal pattern orientation remain explicitly assumed pending exact manufacturer CAD or measurement.
Design iterations and the checks that drove them · Cost review.
The current collars have 10 mm outer diameter and a 5.7 mm assumed bore (2.15 mm nominal radial wall outside the split). Sensor wires route around the perimeter; one passes through a 1.7 mm carrier groove. These are nominal fit reservations, not bend-radius or strain-relief qualification.
Review package and qualification boundary
The package is a review snapshot, not an installable or manufacturing-qualified kit. CAD scripts require CadQuery; the probing replay uses a separately identified task-local simulator candidate. Absolute paths in recorded evidence identify the authoring workspace and must be rebound before reproduction on another workstation. Supplier details and hardware measurements may change the assembly.
Retained-assembly probe replay
The task-local corrected CLI reports zero collision episodes and zero tether snags across233.4seconds and17564 poses, with4698 parts included. The fixture uses the original90-degree orientation and J7 ground. The solver now includes obstacles encountered by the bowed tether before repeating the all-object check; no clearance threshold or tether length changed. Raw collision result · Input-bound full check.
The browser animation does not yet use the same board-obstacle refinement path. Its apparent clearance is not acceptance evidence. The candidate and before/after evidence were handed to the owning issue. Original thermal and final manufacturing gates remain open.
All six nominal CLI checks pass: access, stack, compile, collide, margins and coverage. Coverage reports20 items:19 OK and one nearby same-net landing (TP14 instead of direct L1 access), with no missing or proposed requirements. This is planning evidence, not measured circuit performance.
# Compact R11 — assumed cooling assembly and prototype package
The user authorized geometry, interface and fan assumptions to advance the prototype. This revision adds a direct Q1 insulation stack, side fan, duct, carrier, fastener envelopes, sensor routing and mating-plug reservations. It is a fit study, **not a manufacturing or thermal release**. The 5 W command cap and output lock remain.
The PCB is 72 × 72 mm with large pins at 64 mm spacing. The added cooling assembly occupies an 83.75 × 76.25 × 56.4 mm envelope; total installed height must also include the downward machine pins. This is a compact-board study, not a claim that the whole molecule occupies only the PCB footprint.

::adom-video{src="/adom/adom-custom-electronic-load/render/videos/compact-r11/assembly-current.video.json"}
This silent 18-second assembly review is new footage, separate from the approved narrated film. Fan motion is simulated.
## Reviews and files
- [Layered 3D assembly with animated fan](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/presentation-with-fan.glb) and [cooling STEP](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/cooling-study.step)
- [Assembly instructions and fit targets](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/assembly-instructions.md)
- [Q1 thermal sensitivity review](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/thermal-review.md)
- [Mechanical BOM](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/mechanical-bom.csv)
- [Raw internal intersections](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/assembly-pair-intersections.json) and [explicit contact classification](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/assembly-contact-review.json)
- [Native board intersection check](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/mechanical-intersections.json)
- [Fused fit-part manifest](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/fit-parts/manifest.json): carrier, duct and fan flange each export as one connected solid, with STEP and STL companions.
- [Native PCB fabrication package](/adom/adom-custom-electronic-load/files/revisions/compact-r11/prototype-fabrication/README.md): two-layer 1 oz 3rdPartyFab review files, not an order.
- [Firmware review](/adom/adom-custom-electronic-load/files/revisions/compact-r11/firmware-review.json): compiled output-locked build, 25 kHz assumed bench PWM, no flash.
The contact review found and corrected wafer/sensor overlap, support/wire crossings, collar hardware clearance and harness spacing. Raw results remain available. Thread and connection overlaps are explicitly classified, not silently removed. This does not verify tolerances, strength, material creep, wire bend radius, latch insertion or clamp pressure.
Sink hold-down and fan-flange retention now have explicit assumed hardware. Their strength, thread engagement and manufactured fit are unverified. Exact manufacturer dimensions and measured performance can replace assumptions later. The original thermal failure remains visible; neither a valid GLB nor an interference-free nominal model proves cooling capacity.
The sink is translated 2 mm inward relative to the earlier fit study so its mounting ear clears the large scaffold pin. The latest access revision also moves the cooling group 7 mm toward the front; a sink-side support avoids the test corridor. Ear profile and the 45 mm diagonal pattern orientation remain explicitly assumed pending exact manufacturer CAD or measurement.
[Design iterations and the checks that drove them](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/design-iterations.md) · [Cost review](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/cost-review.md).
The current collars have 10 mm outer diameter and a 5.7 mm assumed bore (2.15 mm nominal radial wall outside the split). Sensor wires route around the perimeter; one passes through a 1.7 mm carrier groove. These are nominal fit reservations, not bend-radius or strain-relief qualification.
## Review package and qualification boundary
The package is a review snapshot, not an installable or manufacturing-qualified kit. CAD scripts require CadQuery; the probing replay uses a separately identified task-local simulator candidate. Absolute paths in recorded evidence identify the authoring workspace and must be rebound before reproduction on another workstation. Supplier details and hardware measurements may change the assembly.
## Retained-assembly probe replay
The task-local corrected CLI reports zero collision episodes and zero tether snags across233.4seconds and17564 poses, with4698 parts included. The fixture uses the original90-degree orientation and J7 ground. The solver now includes obstacles encountered by the bowed tether before repeating the all-object check; no clearance threshold or tether length changed. [Raw collision result](/adom/adom-custom-electronic-load/files/revisions/compact-r11/probing-assumed-assembly/probing-flow/collide.json) · [Input-bound full check](/adom/adom-custom-electronic-load/files/revisions/compact-r11/evidence/assumed-probe-input-review.json).
The browser animation does not yet use the same board-obstacle refinement path. Its apparent clearance is not acceptance evidence. The candidate and before/after evidence were handed to the [owning issue](https://wiki.adom.inc/adom/adom-aiflow-probing/issues/3). Original thermal and final manufacturing gates remain open.
All six nominal CLI checks pass: access, stack, compile, collide, margins and coverage. Coverage reports20 items:19 OK and one nearby same-net landing (TP14 instead of direct L1 access), with no missing or proposed requirements. This is planning evidence, not measured circuit performance.
[Downloadable130-file prototype review bundle and manifest](/adom/adom-custom-electronic-load/files/revisions/compact-r11/prototype-review-package/README.md).