main
John Lauer Publish assumption-based R11 assembly study, locked firmware and new review footage d61d6cb

R11 assumption-based prototype assembly

This is a fit-study package, not authorization to fabricate a qualified product. PCB: 72 × 72 mm, two layers, 1 oz finished copper, large scaffold pins at 64 × 64 mm. Cooling parts occupy an 83.75 × 76.25 × 56.4 mm envelope in native board coordinates; the board and downward machine pins must also be included when calculating the complete molecule height. Native origin is the lower-left PCB corner, Z=0 from the native export. The GLB transform is (-4, -4, +4.005) mm.

Mechanical stack

Q1 tab top is modeled at Z=8.170 mm. Above it: assumed 20 µm contact film, 0.635 mm AlN insulating wafer, another 20 µm film, then the sink bottom at Z=8.845 mm. The wafer is 12 × 18 mm with a 3.4 mm hole. The commercial sink outer reservation is 40 × 40 × 35 mm; base thickness, fin geometry and threaded hole remain assumptions. Do not drill a purchased sink from this fit-study STEP without checking its actual base and permissible engagement.

The carrier supports sink weight independently of Q1 leads. Its rails grip the four large-pin attachment zones with split collars and M1.6 hardware. The exported fit-parts carrier fuses the rail/spine/shelf features into one connected solid; the assembled STEP intentionally preserves named features for review. A 5.7 mm bore is an assumption, not a measured pin fit. The fan flange is a separate assumed 1.5 mm aluminum part with 33 mm mounting centers; the duct closes lateral bypass and directs air along the fins. The revised model adds diagonal sink-ear hold-downs, captive fan nuts, flange-to-duct M2 bolts and sliding duct capture lips. Exact materials, thread engagement and tolerances still require qualification.

Fit targets to verify on the first sample

Interface Nominal study value Prototype acceptance task
Carrier to PCB underside 0.2 mm gap Measure full tolerance stack; reject contact with solder or components
Large pin collar 5.7 mm assumed bore Measure actual pin, print test coupon and establish grip without damage
Fan flange holes 3.2 mm diameter, 33 mm centers Compare actual fan drawing and fastener fit
Insulating wafer 0.635 mm thickness Measure thickness and confirm hole/edge isolation under clamp
Wire reservation 1.3 mm diameter Check actual insulation diameter and bend radius; add strain relief
Sink contact plane Z=8.845 mm Match actual Q1 tab and interface stack without bending leads

No arbitrary torque or plastic strength is specified: actual hardware, material, orientation, temperature and creep data must support those values. A nominal clearance smaller than accumulated tolerances is not an acceptable fit.

Assembly order

  1. Inspect the PCB, verify electrical connectivity, and retain the output-locked firmware. Use the native fabrication files under ../prototype-fabrication/.
  2. Measure the actual pins, Q1 tab, fan and sink. Compare against the assumptions register. Dry-fit carrier and connector insertion before installing the cooler.
  3. Inspect the electrical insulator and shoulder washer. Q1's tab must not electrically short to the common mechanical structure. Check isolation before applying DUT power.
  4. Support the sink on the carrier, align the interface stack and establish the reviewed clamp method. Do not use Q1 leads as a structural support or force the tab to compensate for a stack mismatch.
  5. Fit the fan and duct with its inlet and outlet open. Route the harness outside probe motion and provide strain relief. The straight fan leads in the animated presentation are illustrative; the clearance model carries the intended routing reservations.
  6. Attach the near-case temperature sensor and document the bond and location. Validate sensor lag during controlled heating; proximity alone is not calibrated junction-temperature measurement.
  7. Repeat probe replay using the final measured geometry, including connector insertion, actual bends and all retainers. Perform an unpowered physical fit check before enabling any load.
  8. Follow the existing cooling fixture procedure for independently protected bench validation. Fan tach, PWM, interface resistance and fan-stall shutdown require measurement.

Remaining manufacturing details

The model is sufficient for recorded layout/clearance studies. It is not yet a production drawing: wire strain relief, exact mating connector fit, ear profile, thread engagement and material/fastener tolerances remain open. Keep these distinct from thermal qualification and from the PCB fabrication export, which already exists.

The sink is translated 2 mm inward relative to the earlier fit study so its mounting ear clears the large scaffold pin. The latest access revision also moves the cooling group 7 mm toward the front; a sink-side support avoids the test corridor. Ear profile and the 45 mm diagonal pattern orientation remain explicitly assumed pending exact manufacturer CAD or measurement.

The current collars have 10 mm outer diameter and a 5.7 mm assumed bore (2.15 mm nominal radial wall outside the split). Sensor wires route around the perimeter; one passes through a 1.7 mm carrier groove. These are nominal fit reservations, not bend-radius or strain-relief qualification.