main
John Lauer aiflow run board-codex-20261007-1749: components 8cdcd96

Board model review — v85 prototype

The current board preview is a STEP-derived GLB of AIFlow board 21. Its copper and solder-mask checks pass. This is a geometry review, not a fabrication release or complete cooled molecule.

Watch the actual top-to-underside inspection, 2× · Download review GLB · Copper/mask check

Native KiCad 10.0.5 exported the saved board with components, tracks, pads, zones, solder mask and silkscreen. The exporter reported six wire self-interference warnings. Independent OpenCascade import found 1,110 solids, all valid, and a valid complete imported shape. This does not prove that no geometry was omitted by the exporter. Validity check

Visual inspection covers the populated top, exposed test points, corner pins and underside. The cooler is absent. Exact cooling hardware, mating plugs, harness and clamp/tool access remain to be assembled and checked.

Electrical interface

All eleven interface pad identities agree between the saved PCB and the independent netlist. Their converter coordinates also agree relative to MP1. Names include reference designators so multiple ground contacts remain individually addressable.

Reference Electrical net Unique connection name
J1 DUT_POS DUT_POS_J1
J2 GND GND_J2
J3 5V_AUX 5V_AUX_J3
J4 GND GND_J4
J5 UART_TX UART_TX_J5
J6 UART_RX UART_RX_J6
J7 GND GND_J7
MP1–MP4 GND GND_MP1 through GND_MP4

UART names are from the load's perspective: TX is its output and RX is its input. Auxiliary power is separate from the DUT. These labels do not establish connector current ratings or electrical qualification.

Checked map and limitations · Named footprint derivative · Named symbol derivative · Reproduce the interface audit

The converter's raw outputs are preserved. They use duplicate generic contact names and a simplified symbol representation. Registration/widget compatibility is not validated. The anchoring report also identifies the medium size as an explicit parameter rather than marker-derived. These contract gaps are tracked in adom/adom-step2glb#25; they are not silently waived for final molecule publication.