main
John Lauer Optical setup: product link for the cover glass, simpler Laserland link, drop a dead datasheet link c8e327b

Optical setup and initial checks

Inspired by Breaking Taps' self-mixing interferometer video, The Simplest Interferometer is Actually Complicated.

Light reflected from a moving target travels back into the laser cavity and modulates the laser’s output power. The built-in monitor photodiode measures those changes. Along the beam axis, one fringe represents half a wavelength of target travel. With suitable feedback, the fringe looks like a sawtooth whose slope reverses when the target reverses direction. At 650 nm one fringe is 325 nm of travel. A target moving at 10 mm/s produces about 30.8 kHz. Multiple longitudinal modes can make their fringe patterns interfere with one another. Breaking Taps observed a 1.46 mm amplitude beat and removed it by changing the laser.

Lab supply → reverse protection and filtering → three linear rails
                                         ├→ current driver → laser ⇄ moving target
                                         ├→ analog signal chain
                                         └→ diode-OR with USB → Pico VSYS

Monitor photodiode → selectable TIA → offset and gain → low-pass → ADC0
External photodiode → selectable TIA → offset and gain → low-pass → ADC1
Stage trigger → protected Schmitt input → GPIO15

The undervoltage supervisor inhibits the current driver during startup and shutdown. The soft-start network raises the command gradually. The independent comparator clamps the gate and resets the command if the shunt voltage exceeds its threshold. Each TIA converts photodiode current to voltage. The parallel feedback capacitor limits high-frequency gain. Keeping it close to the amplifier reduces stray capacitance and helps preserve phase margin. Use the offset controls to center the amplified fringes near 1.65 V. The three-pole filter attenuates higher-frequency content before sampling. Pico ADC0 reads the monitor channel, ADC1 reads the external detector, and GPIO15 marks the trigger. For two-channel capture at 500 ksps aggregate, deinterleave successive conversions into two 250 ksps streams. Record the GPIO edge against the same acquisition timebase.

Instrument bill of materials

Role Candidate and supplier Fit or qualification
Recommended single-longitudinal-mode laser Hitachi/Opnext HL6501MG manufacturer datasheet, Thorlabs stockist 658 nm, 5.6 mm can with monitor diode. Manufacturer explicitly specifies one longitudinal mode. Thorlabs gives 65 mA typical and 95 mA maximum operating current at 30 mW and 25 °C. The listing shows stock. The -A ordering variant is marked NRND by its stocking distributor, so verify part and availability on order.
Second single-longitudinal-mode candidate Blue Sky Research VPSL-0685-050-X-5-A/B datasheet Manufacturer specifies a 5.6 mm can with monitor photodiode, 685 nm, 75 mA typical and 120 mA maximum operating current for 50 mW at 25 °C. The A and B packages have different pin assignments. The supplier lists the series as quote to order. Confirm the exact variant, stock and dropout headroom before committing.
Alternate laser candidate Thorlabs L658P040 658 nm, 75 mA typical and 110 mA maximum operating current at 40 mW. Thorlabs catalog V21 calls it single-longitudinal-mode. A later Thorlabs catalog establishes transverse mode only, so confirm the longitudinal spec with the supplier. The stockist lists it in stock.
Multimode trial candidate TULINOPTO TL-650-A05230 Maker lists 650 nm, 5 mW, 17 mA and mode MM in a TO-56 package. Request pricing and confirm the monitor diode, pinout and longitudinal spectrum with the vendor before use.
Documented longitudinal-multimode trial diode Sony SLD1138VL (search the part number for Sony's datasheet) Legacy 650 nm, 5.6 mm DVD diode with a monitor photodiode. Sony specifies 50 mA typical at 4 mW and a 5 mW optical maximum. Suitable for a surplus experiment when an identifiable diode is available. No current stock was verified.
Low-cost laser candidate Thorlabs L650P007 650 nm, 7 mW, 28 mA typical, 35 mA maximum listed operating current, 5.6 mm with monitor diode. The catalog specifies transverse mode only. Longitudinal behavior remains unqualified.
Low-cost starter diode with monitor Arima ADL-65052TL manufacturer data, Laserland stock listing Laserland lists five for $7.98. Arima specifies 20 mA typical and 22 mA maximum operating current at 5 mW and a 7 mW absolute optical rating. The maker specifies a single lateral mode. Treat its longitudinal spectrum as unqualified and verify the lead map, current and optical power before use.
Collimation Thorlabs C220TMD-A, S05TM09, SM05L05 Asphere with an M9 × 0.5 cell, SM05 adapter and short tube. The insulating slide collar mounts to the board's two Ø2.2 mm holes on 16 mm centers. Use black PETG or nylon, two M2 fasteners with blind heat-set inserts, and a nylon M2.5 radial set screw in the collar. Measure the tube diameter and confirm free sliding fit before focusing. Editable bracket model
Return target Thorlabs PS975 or PF05-03-P01 Corner cube for easier return alignment. A mirror needs tip and tilt adjustment.
Attenuator Thorlabs NE10A Start with attenuated feedback.
External detector Vishay BPW34 Start with the 47 kΩ gain option. Use short sensor wiring and adjust the slit to limit background photocurrent.
Digitizer Raspberry Pi Pico SC0915 Fit two Harwin M20-7822046 20-position 2.54 mm sockets and two Harwin M20-9992046 matching male headers onto the Pico.
Bench supply RIGOL DP832 One channel at 12 V with current limiting.
Adjustable slit Two Stanley 28-510 single-edge blades Clamp the backs independently in an insulated holder with the two straight edges facing. Use a micrometer or opposed adjustments to set the opening.
Beam pickoff glass Thorlabs CG15CH2 22 × 22 mm #1.5H cover glass, held at an angle to direct a weak reflection to the slit.
Manual travel Thorlabs MT1 Move the return target along the beam axis.
Motorized travel Thorlabs NRT150 stage family Vendor catalog lists 150 mm travel and 10 mm/s maximum. Confirm the controller and trigger wiring for the exact version.

HL6501MG uses pin code C. Pin 1 is the laser anode, pin 2 is the common laser cathode and monitor anode, and pin 3 is the monitor cathode. Close JP13, JP17 and JP21. Start with JP32 and JP50, then verify monitor bias and output headroom on the actual diode as current is raised. High monitor-current samples can saturate even at 1 kΩ.

The L650P007 and L658P040 use pin code A. The Thorlabs catalog drawing shows pin 1 as laser cathode, pin 2 as common laser anode and monitor cathode, and pin 3 as monitor anode. With that numbering, close JP14, JP16, JP21 and JP31. Begin with JP50 for 1 kΩ monitor gain.

Setup sequence

  1. Wire a current-limited lab supply to VIN and GND. Start with the laser current trimmer at its verified minimum. Use a dummy diode load to check that the sense voltage returns to near zero after shutdown and rises monotonically during startup. Divide the sense voltage by 2 Ω to obtain the shunt current.
  2. With power removed, configure the three polarity bridges against the diode maker’s bottom view and check continuity to LD_A, LD_K and PD_MON. Begin with the monitor TIA on its lower gain. Verify the actual detector reverse-bias polarity and its DC headroom before increasing laser current.
  3. Use an enclosed optical path with a beam stop. Adjust the lens for collimation and bring the target return onto the diode using low optical feedback. Set current from the individual diode’s data and the sense voltage. The board's absolute limit does not protect lower-current lasers against an incorrect trim setting.
  4. Move the target slowly. Scope the monitor TIA and ADC0 test points. Aim for periodic fringes that remain clear of both ADC rails, then reverse direction and verify the sawtooth changes orientation. Watch the fringe envelope over the full travel for fading or beats.
  5. For the second channel, divert a small fraction of the beam with a cover slip and place an adjustable slit in front of the external photodiode. Center ADC1 with the offset trimmer, then capture both ADC channels along with the stage trigger. Adjust the blade gap and the detector position together until fringe amplitude is useful without saturating the TIA.