main
John Lauer
aiflow run board-codex-20261007-1749: components
8cdcd96
1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495969798
{
"status": "nominal-layout-study-not-fabrication",
"boardSha256": "1681eb90e49f4f229afe89bb75ff1738b7503907a52cd174e8b3d64b120082f4",
"sinkHangers": [
[
119.586,
48.06800000000001
],
[
119.586,
86.168
],
[
157.68599999999998,
86.168
]
],
"omittedSinkHole": [
157.68599999999998,
48.06800000000001
],
"fanHolePitchMm": 32,
"fanClearanceDrillMm": 4.5,
"fanRotationDegrees": 45,
"fanHoleCenters": [
[
138.636,
44.49058300203049
],
[
116.00858300203048,
67.11800000000001
],
[
161.2634169979695,
67.11800000000001
],
[
138.636,
89.74541699796953
]
],
"minSinkCountersinkToFanHoleEdgeMm": 13.932992864296285,
"ringBottomAboveBoardMm": 37.84,
"fanBodyTopAboveBoardMm": 59.84,
"bodyConflicts": [],
"probeConflicts": [],
"nutEnvelopeChecks": [
{
"x": 119.586,
"y": 48.06800000000001,
"assumedNutRadiusMm": 3.2,
"assumedNutHeightMm": 1.8,
"bodyConflicts": [],
"used": true
},
{
"x": 157.68599999999998,
"y": 48.06800000000001,
"assumedNutRadiusMm": 3.2,
"assumedNutHeightMm": 1.8,
"bodyConflicts": [
"J8"
],
"used": false
},
{
"x": 119.586,
"y": 86.168,
"assumedNutRadiusMm": 3.2,
"assumedNutHeightMm": 1.8,
"bodyConflicts": [],
"used": true
},
{
"x": 157.68599999999998,
"y": 86.168,
"assumedNutRadiusMm": 3.2,
"assumedNutHeightMm": 1.8,
"bodyConflicts": [],
"used": true
}
],
"validCarrierSolids": true,
"sources": [
"https://wakefieldthermal.com/content/data_sheets/677.pdf",
"https://www.sunon.com/PROSEARCH_FILES/%28D04114960G-01%29-1.pdf"
],
"limitations": [
"Sink is a translucent clearance envelope, not manufacturer fin geometry.",
"Fan is the MIT Adom nominal model: illustrative rotor, no wires, exact G99 connector, guard or motion states in this study.",
"Split edge clamps need tolerances, retention fasteners, insulation material and load/creep validation.",
"Hanger screw length, countersink seating, nuts and tool access remain unselected; cylindrical nut envelope is only a screen. Plate opening/web strength not qualified.",
"No case TIM/clamp or case sensor mounting is modeled.",
"Fan direction, plenum pressure losses and airflow remain unqualified.",
"No PCB drilling or electrical design changes. No release or thermal acceptance."
]
}