main
John Lauer aiflow run board-codex-20261007-1749: components 8cdcd96
{
  "status": "screen-only-not-adopted",
  "source": "https://wakefieldthermal.com/content/catalogs/Thermal_Extrusions_WakefieldThermal-2025.pdf",
  "pdfPage": 9,
  "printedPage": 5,
  "ambientC": 40,
  "q1HeatW": 5.5,
  "caseLimitC": 55,
  "assumedInterfaceAndSpreadingCPerW": 0.52731,
  "maximumSinkCPerW": 2.199962727272727,
  "rows": [
    {
      "stockMpn": "125301",
      "assumedCutLengthMm": 76.2,
      "widthMm": 71.11999999999999,
      "heightMm": 31.75,
      "catalogNaturalCPerW": 2.9,
      "conditionalCaseC": 58.850205
    },
    {
      "stockMpn": "125313",
      "assumedCutLengthMm": 76.2,
      "widthMm": 73.02499999999999,
      "heightMm": 33.324799999999996,
      "catalogNaturalCPerW": 2.3,
      "conditionalCaseC": 55.550205
    },
    {
      "stockMpn": "125319",
      "assumedCutLengthMm": 76.2,
      "widthMm": 76.0984,
      "heightMm": 50.8,
      "catalogNaturalCPerW": 1.5,
      "conditionalCaseC": 51.150205
    }
  ],
  "limits": [
    "Catalog values refer to three-inch natural-convection specimens; operating rise, orientation and installation conditions are not fully specified.",
    "Existing interface/spreading assumption has not been established for these extrusions.",
    "No mounting, fan obstruction, price, final machining or assembly qualification.",
    "No formal spec, board, thermal gate or BOM changes."
  ]
}