Q1 package-cooling review — 16 October 2026
Exploratory model, not accepted cooling qualification. Narrated review.
The PCB-only model deposits Q1 power in its board terminal region and omits its external case/heatsink path. Its extreme Q1, D1 and shunt rises must not be presented as assembled temperatures. The coupled scenario instead attaches a junction/case/sink resistance network to the board solver and accounts for heat entering the board through the leads.
This is a coupled PCB field plus lumped package model. It does not resolve temperature gradients along individual heatsink fins, CFD airflow, spreading in the real clamp, or startup/fan-failure transients. Spatial heatsink validation remains open.
Same R6 geometry and electrical inputs
- 72×72mm, two layers,35µm copper; Q1 source5.5W, D1 approximately0.513W, shunt approximately0.030W.
- Q1 junction-to-case0.42K/W; assumed interface0.7K/W.
- Assumed sink-to-air8K/W still,1.2K/W moving. The moving value represents a catalog ducted-airflow scenario, not measured installed fan performance.
- Three lead-to-board links each100K/W, explicitly assumed.
- Ambient-relative rises below; add actual ambient for temperature. Preserve the Q1-specific15°C rise budget (the general board budget is35°C),5W bring-up cap and output lock.
| Node | Still-air rise | Assumed-airflow rise |
|---|---|---|
| Q1 junction | 49.55°C | 12.75°C |
| Q1 case | 47.24°C | 10.44°C |
| Heatsink lumped node | 43.44°C | 6.59°C |
| D1 board screening node | 30.20°C | 21.50°C |
| RSH1 board screening node | 14.90°C | 7.50°C |
Q1 exceeds its15°C rise budget in still air. Active cooling looks promising under these assumptions; no fan-off continuous-power pass is recorded. The result does not establish fault-shutdown timing, tach reliability, sensor lag, contact pressure or safe operating area. Those checks remain required.
The separate R6 DUT_FUSED current screen still fails at approximately74A/mm² against60. R7 changes the elbow geometry and requires its own native/current/thermal/probing evidence. This R6 review cannot qualify R7.
Evidence
- fields-input.kicad_pcb; SHA256
ff225bcdf794dd7465f5a581a7a34e9fab8b32267ad1decf9761bbb9b955c4f4. - spec-package-scenario.json; SHA256
95b50359f28a0bf8c8792baaf1f2916da024e182a65ae1e63c7551c163b4d9a9. - fields-package-scenario/fields.json; SHA256
889d279e23dc87d71fcf364d0fe96f6f172fde624c9849ff80d467b03caee5bc. - package-scenario-provenance.json; SHA256
f68b3f6b41d9471275cf28c7700525f03a7e8d1f9ab1430f4aef0ad2d181b239.
# Q1 package-cooling review — 16 October 2026
Exploratory model, not accepted cooling qualification. [Narrated review](remote-service-clips.md).
The PCB-only model deposits Q1 power in its board terminal region and omits its external case/heatsink path. Its extreme Q1, D1 and shunt rises must not be presented as assembled temperatures. The coupled scenario instead attaches a junction/case/sink resistance network to the board solver and accounts for heat entering the board through the leads.
This is a coupled PCB field plus lumped package model. It does **not** resolve temperature gradients along individual heatsink fins, CFD airflow, spreading in the real clamp, or startup/fan-failure transients. Spatial heatsink validation remains open.
## Same R6 geometry and electrical inputs
- 72×72mm, two layers,35µm copper; Q1 source5.5W, D1 approximately0.513W, shunt approximately0.030W.
- Q1 junction-to-case0.42K/W; assumed interface0.7K/W.
- Assumed sink-to-air8K/W still,1.2K/W moving. The moving value represents a catalog ducted-airflow scenario, not measured installed fan performance.
- Three lead-to-board links each100K/W, explicitly assumed.
- Ambient-relative rises below; add actual ambient for temperature. Preserve the Q1-specific15°C rise budget (the general board budget is35°C),5W bring-up cap and output lock.
| Node | Still-air rise | Assumed-airflow rise |
|---|---:|---:|
| Q1 junction | 49.55°C | 12.75°C |
| Q1 case | 47.24°C | 10.44°C |
| Heatsink lumped node | 43.44°C | 6.59°C |
| D1 board screening node | 30.20°C | 21.50°C |
| RSH1 board screening node | 14.90°C | 7.50°C |
Q1 exceeds its15°C rise budget in still air. Active cooling looks promising under these assumptions; no fan-off continuous-power pass is recorded. The result does not establish fault-shutdown timing, tach reliability, sensor lag, contact pressure or safe operating area. Those checks remain required.
The separate R6 DUT_FUSED current screen still fails at approximately74A/mm² against60. R7 changes the elbow geometry and requires its own native/current/thermal/probing evidence. This R6 review cannot qualify R7.
## Evidence
- [fields-input.kicad_pcb](../revisions/compact-r11/current-repair-r6/fields-input.kicad_pcb); SHA256 `ff225bcdf794dd7465f5a581a7a34e9fab8b32267ad1decf9761bbb9b955c4f4`.
- [spec-package-scenario.json](../revisions/compact-r11/current-repair-r6/spec-package-scenario.json); SHA256 `95b50359f28a0bf8c8792baaf1f2916da024e182a65ae1e63c7551c163b4d9a9`.
- [fields-package-scenario/fields.json](../revisions/compact-r11/current-repair-r6/fields-package-scenario/fields.json); SHA256 `889d279e23dc87d71fcf364d0fe96f6f172fde624c9849ff80d467b03caee5bc`.
- [package-scenario-provenance.json](../revisions/compact-r11/current-repair-r6/package-scenario-provenance.json); SHA256 `f68b3f6b41d9471275cf28c7700525f03a7e8d1f9ab1430f4aef0ad2d181b239`.