main
John Lauer
Record issue repair evidence, published fixes and remaining qualification gaps
8640c6a
{
"animationRequired": false,
"findings": [
{
"check": "sweptVolume",
"hint": "Check approach, engagement, loosening and extraction swept volumes against PCB, components, wires, scaffold and enclosure.",
"id": "heatsink-NTC-M3x4",
"severity": "error"
},
{
"check": "revision",
"hint": "Bind access-hole and collision evidence to the current PCB and assembly hashes.",
"id": "heatsink-NTC-M3x4",
"severity": "error"
}
],
"hint": "Optional tool animation helps review assembly; it does not replace swept-volume checks or qualify physical fit.",
"passed": false,
"schemaVersion": 1
}