  "animationRequired": false,
  "findings": [
    {
      "check": "sweptVolume",
      "hint": "Check approach, engagement, loosening and extraction swept volumes against PCB, components, wires, scaffold and enclosure.",
      "id": "heatsink-NTC-M3x4",
      "severity": "error"
    },
    {
      "check": "revision",
      "hint": "Bind access-hole and collision evidence to the current PCB and assembly hashes.",
      "id": "heatsink-NTC-M3x4",
      "severity": "error"
    }
  ],
  "hint": "Optional tool animation helps review assembly; it does not replace swept-volume checks or qualify physical fit.",
  "passed": false,
  "schemaVersion": 1
}