Record issue repair evidence, published fixes and remaining qualification gaps

John Lauer ·8640c6addd · ·parent 415d1de
3 files changed +245
docs/issue-repairs-20261028/README.mdadded+31
@@ -0,0 +1,31 @@+# Wiki issue repairs — 28 October 2026++Work in progress. No fabrication or purchase approval.++## Electronic-load #1++Native KiCad 10.0.3 on arav-rog preserved the original 1.2 mm SHUNT_P traces and extended the source pour toward Q1.3. The first 1.5 mm trace candidate was rejected for Kelvin-pad/gate clearances. Latest adopted candidate is AIFlow board-17, including a DRC-clean 0.6/0.3 mm source via at (134.8,86.0) mm. A continuous B.Cu source region reaches both Q1.3 and RSH1.1, with 0.25 mm local clearance; the absorbed empty zone was removed. Native DRC: zero errors and zero opens; warnings remain. Service DRC did not reproduce desktop sidecar-rule handling and is not used as acceptance evidence.++LOAD_POS U4.8 is declared sense-only (0 A) in the conductor-capacity screen. Its original nominal 28.916 uA bias remains in the saved pre-change spec and notes. AIFlow records the amendment; 3 A load and 10 C rise limits are unchanged. LOAD_POS passes. All six loaded nets now pass the conservative copper screen. A fresh 0.2 mm Fields solve completed on board-16 and reports a roughly 61 A/mm² SHUNT_P hotspot against 60 A/mm², 11.9 mV ground offset against 10 mV, and thermal failures in the PCB-only model. Board-16 watched solve reproduced the hotspot. The board-17 0.2 mm watched solve completed: SHUNT_P still fails at 60.4 A/mm². A 0.1 mm full-spec watched solve is in progress to check grid convergence. An extra via at (124.9,83.4) mm was rejected after its diagnostic-only solve worsened the hotspot to 71 A/mm²; that candidate was not adopted. The board is not qualified; full assembled thermal modeling is still required. The earlier board-13 solve was terminated as obsolete; no result from it is used. Do not claim this issue resolved yet.++## JLCPCB #2++Candidate shared rule generator and 2/4/6-layer JLC profiles remove the track-only clearance condition. Native two-pad B.Cu regression fixture correctly rejects a 0.09 mm gap under the 0.10 mm rule. Working source: /home/adom/project/pcb-design-rules-issue-repair. Published and read back generator/profiles/evidence at e15d2c4f0847b3850e7ca95983247afd67def605. JLCPCB issue #2 is closed. Its rules command retrieves profiles live; no binary update is needed for the profile correction. Source skill guidance published at 0521d27a8756b10197e6b94fc1eee3c6ebfafa34; installed skill release is separate.++## AIFlow #60++Mechanical and wiring package manifests/installers prepared, release binaries built and installed locally. Five existing mechanical/wiring Rust unit tests and five PCBWay tests pass. Project input reviews still fail: two mechanical findings and 31 wiring findings (reports beside this document). Tools are declaration checks, not collision solvers. Source archives (including Linux x64 executables) published on this project at 415d1de583b2a706e8f75de793ac8f69373f6071 and linked from AIFlow #60. Shared registry releases and full geometry solver remain unfinished. The old service-review JSON is not evidence bound to board-17.++## PCBWay publication++Corrected .gitignore so the declared bin/ is included. App hero still missing; Hero Studio preview preparation is in progress. Its first Generate requires the human. Ordinary wiki writes now work; attachment upload still returned 401, so archives were published through repo push. Source and package remain local. No new RFQ or payment submitted.++## Media++No clip recorded for these repairs: AIFlow reported no PCB editor open on its selected capture machine. Native edits ran headlessly on arav-rog. Do not represent these as recorded live UI work.++## Additional release dependencies++Hero Studio preview opened on port 8967 but cannot load the private Adom brand guide with the expired identity; no approved hero generated. Mechanical/wiring packaging also needs truthful showcase images and approved heroes. The JLC workflow skill now instructs checking all-copper coverage; source guidance is now published; installed availability remains separate.++Native board-17 warning inventory: 182 text-thickness, 182 text-height, 66 footprint-library, and 2 hole-to-hole warnings. Zero errors is not a warning disposition or manufacturing qualification. These remain visible in via-qualified-drc.json.
docs/issue-repairs-20261028/mechanical-current.jsonadded+20
@@ -0,0 +1,20 @@+{+  "animationRequired": false,+  "findings": [+    {+      "check": "sweptVolume",+      "hint": "Check approach, engagement, loosening and extraction swept volumes against PCB, components, wires, scaffold and enclosure.",+      "id": "heatsink-NTC-M3x4",+      "severity": "error"+    },+    {+      "check": "revision",+      "hint": "Bind access-hole and collision evidence to the current PCB and assembly hashes.",+      "id": "heatsink-NTC-M3x4",+      "severity": "error"+    }+  ],+  "hint": "Optional tool animation helps review assembly; it does not replace swept-volume checks or qualify physical fit.",+  "passed": false,+  "schemaVersion": 1+}
docs/issue-repairs-20261028/wiring-current.jsonadded+194
@@ -0,0 +1,194 @@+{+  "animationRequired": false,+  "findings": [+    {+      "check": "pinColorEvidence",+      "hint": "Verify actual supplier wire colors and contact numbering from the mating-face view; do not infer colors from conventions.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "terminalFitEvidence",+      "hint": "Verify exact crimp contact, housing and header compatibility, wire AWG, insulation OD, strip length and tooling.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "releaseEvidence",+      "hint": "Identify housing latch release separately from terminal depinning; specify tools and safe grip points.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "forceEvidence",+      "hint": "Record supplier or measured mating/unmating force in newtons and test conditions. Unknown force is unresolved; do not invent it.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "sweptClearanceEvidence",+      "hint": "Verify insertion and extraction travel, latch/tool/finger envelopes, and cable motion against the current assembly.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "bendEvidence",+      "hint": "Verify supplier minimum bend radius, insulation envelope, slack and terminal strain relief.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "retentionEvidence",+      "hint": "Specify cable clips or printed holders, attachment, edge protection, temperature compatibility and service release.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "neighborServiceClearanceEvidence",+      "hint": "Check every neighboring connector mating, withdrawal and latch/tool corridor against wire envelopes, including sag and tolerances.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "revisionEvidence",+      "hint": "Bind this review to board, assembly and harness revision hashes.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "conductorCount",+      "hint": "Match physical conductor count to the connector pin inventory; reject duplicate decorative leads.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "physicalId",+      "hint": "Assign one stable physical ID per conductor and reference its scene nodes.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "continuousGeometryEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "entryAxisEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "housingIntersectionEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "bendRadiusEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "physicalId",+      "hint": "Assign one stable physical ID per conductor and reference its scene nodes.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "continuousGeometryEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "entryAxisEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "housingIntersectionEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "bendRadiusEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "physicalId",+      "hint": "Assign one stable physical ID per conductor and reference its scene nodes.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "continuousGeometryEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "entryAxisEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "housingIntersectionEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "bendRadiusEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "physicalId",+      "hint": "Assign one stable physical ID per conductor and reference its scene nodes.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "continuousGeometryEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "entryAxisEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "housingIntersectionEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "bendRadiusEvidence",+      "hint": "Verify one continuous insulated conductor, aligned straight crimp entry, no housing-wall penetration or self-intersection, and minimum bend radius. Inspect actual scene geometry, not only the manifest.",+      "id": "fan-J9",+      "severity": "error"+    },+    {+      "check": "length",+      "hint": "Required cut length including service slack and termination allowances must fit minimum supplied length.",+      "id": "fan-J9",+      "severity": "error"+    }+  ],+  "passed": false,+  "qualification": "Review completeness only; evidence paths require independent review, not proof of physical fit.",+  "schemaVersion": 1+}