main
Name Last commit message Last updated
copper-review-video Record rejected board-21 fine result and verified review-video playback; preserve open gates · John Lauer
video Publish board-19 copper repair candidate and require unresolved assembly reviews · John Lauer
adom-aiflow-mechanical-review-source.tar.gz Document intended-contact limits and complete-assembly requirements for service sweeps · John Lauer
adom-aiflow-pcbway-review-source.tar.gz Preserve tested PCBWay RFQ application source pending standalone page publication · John Lauer
adom-aiflow-wiring-review-source.tar.gz Add narrated retrospective copper/access review clip with separate captions and current board-21 status · John Lauer
mechanical-current.json Record issue repair evidence, published fixes and remaining qualification gaps · John Lauer
README.md Record current-board thermal failure without substituting PCB-only results for the cooling assembly · John Lauer
remaining-dependencies.md Resolve load current-path issue with verified board22 broader source pour; preserve remaining thermal and service gates · John Lauer
wiring-current.json Record board-20 copper candidate and bounded sensor service-access diagnostics without claiming acceptance · John Lauer

Wiki issue repairs — 28 October 2026

Work remains in progress. No fabrication, purchase or physical qualification is implied.

Item Verified progress Remaining work
JLCPCB #2 Shared clearance generator and 2/4/6-layer profiles now cover all copper. Native 0.09 mm pad-gap fixture fails the 0.10 mm rule as intended. Issue closed. Broader 3rdPartyFab profile work is separate.
Electronic-load #1 Board-22 passes native DRC (zero errors, warnings and opens), AIFlow current, and the full-spec 0.1 mm current-density screen. SHUNT_P is 57.315754 A/mm², below the unchanged 60 limit. LOAD_POS U4.8 is correctly a sense terminal. Current-path issue resolved; downstream thermal, mechanical and wiring acceptance remains open.
AIFlow #60 AIFlow 0.2.26 published, downloadable and installed. Geometry reports bind to the active board, request, report and STEP hashes; stale inputs are rejected. 496 workspace tests pass, nine existing tests ignored. Actual board assembly review, wiring findings, standalone Mechanical/Wiring page releases.
PCBWay page Public MIT app 0.1.1, source, approved hero, Linux release, installed binary and discovery verified. Real page inspected in Pup on arav-rog. No new vendor quote or purchase was submitted during these repairs.

Board evidence

The active run is aiflow/compact-r11, board-22, SHA-256 197e48d41c905773c8c8db092c9db5a255f0b0b919eaf3b645080399c93467d7. The accepted copper repair broadens the upper SHUNT_P bottom-layer pour, with native refill preserving clearances. All six loaded nets pass the unchanged full 0.1 mm current-density screen; AIFlow current analysis passes. Exact inputs and native evidence and AIFlow result are published. This is an engineering screen, not hardware qualification. Earlier board-20 and board-21 failures are retained as rejected candidates.

LOAD_POS U4.8 is represented as a sense terminal (0 A) for the conductor-capacity screen; its original nominal 28.916 µA input bias remains recorded in the saved spec and amendment notes. The 3 A design load, 60 A/mm² current limit and 10°C copper-rise budget are unchanged. No peak acknowledgment or acceptance waiver has been used.

Board-18 uses a 2.4 × 3 mm oval Q1 source pad and a rerouted bottom drain approach. The full watched fine-grid solve still fails. A rounded-rectangle source-pad candidate is native-DRC clean but its tapered-source diagnostic fails at 82.48 A/mm². The wider-exit rounded candidate failed the 0.1 mm diagnostic at 73.3239 A/mm². Neither rounded candidate was adopted. Two front-feed vias plus a wider source pour reduced the coarse diagnostic peak to 58.5158 A/mm², now at a shunt-side via. Board-19 adds a 1.2 mm front track from that via to RSH1.1 to eliminate its narrow overlap; native DRC is clean, but the full-spec fine-grid solve still fails at 65.8873 A/mm² at (126.45, 82.75), B.Cu. Removing that stub failed at 128.3 A/mm²; extending it failed at 67.9 A/mm². Broadening the upper pour in board-22 finally passes at 57.3 A/mm².

PCB-only thermal results omit the assembled cooling path and must not be represented as the heatsink-cooled Q1 temperature or hardware qualification. Full assembled thermal evidence remains required.

Mechanical geometry implementation

The mechanical tool now performs actual CadQuery/OCCT intersections of continuous conservative cylindrical tool sweeps with STEP solids. It supports fixed-axis translation through approach, engagement, withdrawal and extraction. Angled articulation is refused. Intended contact/removal exclusions require reasons; excluding every solid is refused.

Nine geometry/CLI tests pass, including a real STEP hole, an oversized colliding tool, stale geometry, missing stages and a bare verification Boolean. Two Rust tests also pass. These are synthetic regression fixtures, not electronic-load acceptance. Reports retain physicalQualification: false; assembly completeness, registration, actual tools, tolerance and torque still require review.

The updated source archive is adom-aiflow-mechanical-review-source.tar.gz. Actual project reviews remain unresolved: two mechanical findings and 44 wiring findings after adding the previously omitted sensor harness. These reviews are now declared as required before finish. Those adjacent JSON reports describe the earlier board-20 review and are not board-22 acceptance; the CLI logs are under revisions/compact-r11/issue-1-copper/. Wiring currently audits declarations and conductor IDs, not arbitrary mesh collisions.

Release evidence

  • Shared JLC rule source: e15d2c4f0847b3850e7ca95983247afd67def605.
  • AIFlow geometry source: 4f0f19fe412eccd9811ef08a5ea263834a17458b.
  • AIFlow 0.2.26 installed/release binary SHA-256: ada29f3ec618e7875cca2d6b2fb71b930c6a2f219a9a123a955a45e36cb1a947; existing CLI help unchanged.
  • PCBWay 0.1.1 installed/release binary SHA-256: faa040942eae9cf56f314039156603a4d46f69386c314d64b6638d3b600ca911.
  • PCBWay workflow tests cover incomplete totals, changed inputs, stale exports, duplicate initialization, vendor receipts, webview default, explicit Pup and account identity.

Media

Download the 33-second narrated review clip. Captured and edited on arav-rog, with Adom TTS and separate captions. Full decode, sampled frames and silence checks passed. This is a retrospective page walkthrough; headless CAD edits were not filmed. Raw footage remains remote. This clip has not been approved for inclusion in the final film.

Publication dependency

The PCBWay hero approval is complete. Reusing its approved style for the Mechanical/Wiring pages is awaiting the user's answer to the explicit Hero Studio batch-approval question. Their source archives remain available here meanwhile.

Board-20 service-access diagnostics

Native KiCad exported the board and its referenced component models without missing-model warnings. A conservative straight-driver and screw-envelope diagnostic passes against those populated board solids. Extending it to 635 board/cooling/sensor solids passes approach, engagement and driver withdrawal, but reports extraction overlaps at the sensor lug and fin-base region. Independent exact-size intersections are zero; the 0.2 mm safety margin creates those contacts at the seated screw position. These are contact-aware sequencing work, not evidence that the board hole is blocked. No required mechanical gate was marked passed.

This diagnostic still omits the fan, fan harness, scaffold, hand and sensor-lug extraction sequence. Tool dimensions remain provisional. The raw report deliberately remains failed until a defensible complete service sequence is represented; intended-contact exclusions are documented, not hidden.

The wiring linter now also rejects duplicate physical IDs across different harnesses, duplicate harness IDs and unsupported schema versions. Six unit tests pass; local binary installed, updated source archive published. Standalone registry release remains pending.

Follow-up repair-review clip

Watch/download the 26-second copper and access review. Retrospective wiki walkthrough, captured and encoded on arav-rog; Adom TTS narration, separate captions, no burned text. Shows the failed candidate honestly. It is not original CAD-edit footage and is pending review for the final film.

Board-22 thermal gate readback

AIFlow thermal output remains failed on the current board. The copper heuristic passes D1 and RSH1 but fails Q1; the same-input PCB-only Fields screen also exceeds the D1 rise budget. Because this solve omits the external Q1 package/heatsink path, its hot-board values do not establish actual assembled temperatures. The earlier supplier-informed package study separately fails Q1’s unchanged 15°C rise limit. A complete cooling model and acceptable physical design are still required. Current-path issue #1 is closed; whole-board acceptance is not.