c9b1be2
Explicit terminal current diagnostic
The current gate remains open. The previous width-only check assigns the whole 3 A net load to the narrow DUT voltage-sense branch and to a secondary parallel fuse trace. The replacement needs actual circuit boundary conditions, rather than a waiver of the conductor limits.
On 10 October an isolated Fields source candidate added signed pin currents, uniqueness/net validation, balanced source/sink totals and refusal to publish partially solved loaded nets. It is based on the unmerged physical two-layer-stack branch at a12b30f6cd5bf87af73cae2e62420529c5b14449; it does not replace installed Fields 0.6.2. All 25 combined tests and production compilation passed. The new regressions cover a fuse/diode path with a separate sense sink, current reversal and rejection when a terminal has no copper.
The actual saved board-19 diagnostic at 0.2 mm uses explicit 3 A main paths for DUT_POS, DUT_FUSED, LOAD_POS, SHUNT_P and GND. All six loaded nets converged below 1e-7 residual; peak density is 57.9 A/mm² on SHUNT_P against the unchanged 60 A/mm² screen. Other main nets are 42.3–47.8 A/mm². The auxiliary supply still uses heuristic terminal allocation. Exact input identities, assignments, source candidate and binary identity are in design/step12-explicit-terminal-summary.json.
This is not a current-gate pass. Main-path boundary conditions omit sense currents and alternate fixture returns. The existing terminal injection uses a 1 mm neighborhood, not exact package contacts. Full branch/auxiliary scenarios, resolution sensitivity and integration with AIFlow's conservative conductor screen remain required.
All three hot-part checks still fail in the board-only model. Its Q1 heat is incorrectly constrained to the board for the intended external case-mounted heatsink assembly, which is absent from this solve. These temperatures must not be presented as a prediction of the proposed cooled assembly, and the current results must not be presented as thermal qualification. No finish or fabrication acceptance was recorded.
Branch and auxiliary checks
The sense-branch diagnostic retains 3 A into F1 and adds 0.2204 mA for a 24 V divider with both resistors at -1 percent. INA226 VBUS uses its documented typical 830 kohm input (28.916 uA at 24 V), explicitly not a guaranteed maximum. ADC leakage is not modeled.
The auxiliary sweep assigns the entire 0.3 A from J3.1 to each consumer in turn: J9.1, U9.1, U9.3, U5.4, U5.5 and L1.1. Peaks range from 21.6 to 24.2 A/mm². This bounds fixed-conductivity linear DC mixtures under the assumed total current; it does not validate that budget or capacitor/boost transient currents. See design/aux-current-envelope/summary.json.
An independent centerline resistor calculation and a new isolated AIFlow Rust implementation agree: DUT_POS maximum track rise is 3.542 C or 2.982 C for the two J1 source-layer extremes; DUT_FUSED is 3.933 C. The thin sense branch carries 0.2204 mA, and the 1 mm parallel fuse branch about 0.378 A. The Rust screen also reports maximum barrel density of 33.43 A/mm² for DUT_POS and 11.33 A/mm² for DUT_FUSED, under explicit nominal plating assumptions. Pads are approximated as equipotential central contact regions; filled-copper and actual contact qualification remain separate. These results are not installed gate acceptance.
Fields owner handoff: PR 6, explicitly stacked on PR 5. Source tests, submitted diff and saved-board diagnostics were verified; no shared runtime was changed.
# Explicit terminal current diagnostic
The current gate remains open. The previous width-only check assigns the whole 3 A net load to the narrow DUT voltage-sense branch and to a secondary parallel fuse trace. The replacement needs actual circuit boundary conditions, rather than a waiver of the conductor limits.
On 10 October an isolated Fields source candidate added signed pin currents, uniqueness/net validation, balanced source/sink totals and refusal to publish partially solved loaded nets. It is based on the unmerged physical two-layer-stack branch at `a12b30f6cd5bf87af73cae2e62420529c5b14449`; it does not replace installed Fields 0.6.2. All 25 combined tests and production compilation passed. The new regressions cover a fuse/diode path with a separate sense sink, current reversal and rejection when a terminal has no copper.
The actual saved board-19 diagnostic at 0.2 mm uses explicit 3 A main paths for DUT_POS, DUT_FUSED, LOAD_POS, SHUNT_P and GND. All six loaded nets converged below 1e-7 residual; peak density is 57.9 A/mm² on SHUNT_P against the unchanged 60 A/mm² screen. Other main nets are 42.3–47.8 A/mm². The auxiliary supply still uses heuristic terminal allocation. Exact input identities, assignments, source candidate and binary identity are in `design/step12-explicit-terminal-summary.json`.
This is not a current-gate pass. Main-path boundary conditions omit sense currents and alternate fixture returns. The existing terminal injection uses a 1 mm neighborhood, not exact package contacts. Full branch/auxiliary scenarios, resolution sensitivity and integration with AIFlow's conservative conductor screen remain required.
All three hot-part checks still fail in the board-only model. Its Q1 heat is incorrectly constrained to the board for the intended external case-mounted heatsink assembly, which is absent from this solve. These temperatures must not be presented as a prediction of the proposed cooled assembly, and the current results must not be presented as thermal qualification. No finish or fabrication acceptance was recorded.
## Branch and auxiliary checks
The sense-branch diagnostic retains 3 A into F1 and adds 0.2204 mA for a 24 V divider with both resistors at -1 percent. INA226 VBUS uses its documented typical 830 kohm input (28.916 uA at 24 V), explicitly not a guaranteed maximum. ADC leakage is not modeled.
The auxiliary sweep assigns the entire 0.3 A from J3.1 to each consumer in turn: J9.1, U9.1, U9.3, U5.4, U5.5 and L1.1. Peaks range from 21.6 to 24.2 A/mm². This bounds fixed-conductivity linear DC mixtures under the assumed total current; it does not validate that budget or capacitor/boost transient currents. See `design/aux-current-envelope/summary.json`.
An independent centerline resistor calculation and a new isolated AIFlow Rust implementation agree: DUT_POS maximum track rise is 3.542 C or 2.982 C for the two J1 source-layer extremes; DUT_FUSED is 3.933 C. The thin sense branch carries 0.2204 mA, and the 1 mm parallel fuse branch about 0.378 A. The Rust screen also reports maximum barrel density of 33.43 A/mm² for DUT_POS and 11.33 A/mm² for DUT_FUSED, under explicit nominal plating assumptions. Pads are approximated as equipotential central contact regions; filled-copper and actual contact qualification remain separate. These results are not installed gate acceptance.
Fields owner handoff: [PR 6](https://wiki.adom.inc/adom/adom-fields/prs/6), explicitly stacked on PR 5. Source tests, submitted diff and saved-board diagnostics were verified; no shared runtime was changed.