7007e93
Compact R11: implementation in progress
The compact revision is now in AIFlow. The target is a 72 × 72 mm, two-layer, 1 oz 3rdPartyFab board with large machine pins on a 64 × 64 mm pattern. Board34/R10 remains the preserved previous design. The 5 W firmware limit and existing temperature protections are unchanged.

This image is a native KiCad CPU rendering of the saved compact v5 board, with copper and silkscreen. The fan/heatsink assembly is not shown in this bare-board image. The retained assembly has a separate linked review below.
Implemented and checked
- Cropped the PCB outline to the 72 mm target and moved the upper machine pins to the matching 64 mm span.
- Moved USB-C down the same board edge to clear the upper-right machine pin.
- Added a keyed four-wire fan header, open-drain PWM driver, pull-up/pull-down network and dedicated PWM test point.
- Connected previously unused STM32 PA8 to the fan PWM circuit.
- Native schematic export matches all 288 connected logical PCB pins across 112 references.
- Native refill/save/reload preserved 2,308 track, via and pad net assignments.
- The subsequent routed checkpoint passes native DRC with zero errors and zero missing connections after repairing ground connectivity. The subsequent placement tidy removes obsolete corner-border strokes and clears Q5 from J9’s courtyard; the latest v4 cleanup now has zero errors, zero warnings and zero unconnected items. It removes the obsolete fan-supply stub and resolves project-local libraries. V5 now relocates J7 onto the front access bank, detours the PWM trace locally and updates the R11 labels; it also has zero native errors, warnings and opens. V5 is adopted into AIFlow; the fresh current screen passes and cooling acceptance remains open.
- Variable tach telemetry passes wrap, glitch, stale and slow-speed load-refusal tests. A mixed-speed transition test retains the original 15 ms stale bound at load-qualified reported speeds. All 240 synthetic shutdown scheduler cases pass. These are software tests, not hardware timing measurements.
Machine-readable progress evidence · Native netlist parity · Latest candidate native DRC
Latest verification
All 112 placements now match the saved PCB in a native live-editor check. All 95 modeled references resolve; 17 bare/mechanical features require no component body. The expanded test plan maps all 18 measurements to accessible board-level points, including PWM, tach and temperature. Assembled cooler/probe access remains a separate unfinished gate.
The fan runtime test confirms off-pose stability, rotor-only motion, fixed housing and a pause for invalid telemetry. A reviewed 31.8-second Pup clip captures the illustrative speed ramp and orbit. This is model-review footage, not measured fan motion.

Fan wiring and motion notes · Prepared physical cooling test procedure
Electrical and probe evidence
The fresh v5 filled-copper solve passes its 0.1 mm current screen, including explicit terminal and plated-barrel checks. This is a computed engineering screen, not physical qualification. All 112 v5 placements match the isolated native editor, and the exact 288-pin schematic parity passes.
Corrected probe screening: the old checker incorrectly selected a 4 × 4 mm PCB corner as the whole board and omitted large obstacles. Its earlier clearance claim was withdrawn. The isolated repair includes the full board, large cooling bodies and the complete moving head. The original cooler placement then failed with 24 collision episodes and six snags.
V5 uses a side-fan reservation and a 90-degree scaffold orientation, with J7 moved to local (10,4) mm on the original grid. A fresh 231.7-second replay using the actual v5 board has zero collision episodes and zero tether snags. This is main-body envelope screening only: mounting ears, clamp, duct, sensor and fan harness remain absent. Repair and replay evidence.
Published component pages now include the fan, board header and cable housing. The fan runtime supports rotor-only RPM motion; animation is illustrative telemetry, not measured fan behavior.
Q1 package-path sensitivity review explains why PCB-only heating overstated the temperature around the rectifier, and why the final thermal gate is still open.
Cooling under review
The working heatsink is the ATS-FPX040040035-66-C2-R0, 40 × 40 × 35 mm, with a 45 × 45 mm hole pattern. The working fan is the Same Sky CFM-4010-03-22, 40 × 40 × 10.6 mm, with tach and PWM leads. Procurement snapshots are $6.82 and $10.82 respectively, excluding clamp, insulation, connector, mounting hardware, shipping and tax.
Exact source and limitations. Manufacturer STEP was obtained for the fan. The heatsink CAD link requires a manufacturer login; detailed fin geometry is not yet verified. Catalog ducted resistance does not establish installed airflow or the localized Q1 thermal path. No higher wattage is released.
Remaining gates
Physical cooling/interface/fan validation and the original AIFlow thermal/final-release gates remain open. Assumed retained assembly, output-locked PWM firmware, PCB fabrication review exports and the4:09 film are now published. Complete assembly replay is being finalized; inspect its input-bound result rather than the earlier body-only pass. The earlier concept thermal solve and R10 probe replay do not qualify this revision.
Recording
Six individually narrated and captioned review clips are ready: compact board, fan states, Q1 heat path, the failed clearance layout, the revised side-fan arrangement and fresh current results. All six have caption timing within their media and no detected silence of 0.7 seconds or longer. The thermal scene is an authored chart; the others identify their recorded or saved-result origin. Blank native-editor takes are excluded. All six R11 clips are approved and included in the published4:09 progression film. New assembly footage remains separate for review.
Completion plan · Previous design and video
Latest v5 engineering evidence

All 18 planned board measurements have landings. Fresh model resolution finds 95 component models and 17 intentionally bare features; all offline orientation checks now resolve, including J9 after its local model copy was hash-matched to the native desktop model. The nominal cooling-body replay and margins pass; that historical check does not include the newer retained assembly.
The isolated R11 STM32 bring-up image compiles with PA8 explicitly releasing the fan PWM input high during startup and fault handling. Load output is permanently locked off. Variable PWM frequency and zero-duty behavior remain unqualified; no hardware was flashed.
Six individual narrated/captioned progression scenes are prepared for storyboard review, including the revised side-fan arrangement. The six scenes are approved and assembled into the4:09 progression film; newer assembly footage is separate. Blank native-editor recordings are excluded, not presented as successful editing footage.
Assumption-based assembly iteration
Current mechanical and build-package review. This work proceeds under the user-authorized assumptions; it does not pass thermal or manufacturing qualification.
Combined 4:09 design-progression film combines earlier R10 footage with the six approved R11 clips.
Prototype specification
Current R11 prototype datasheet records command limits, interfaces, package dimensions and qualification boundaries.
# Compact R11: implementation in progress
The compact revision is now in AIFlow. The target is a 72 × 72 mm, two-layer, 1 oz 3rdPartyFab board with large machine pins on a 64 × 64 mm pattern. Board34/R10 remains the preserved previous design. The 5 W firmware limit and existing temperature protections are unchanged.

This image is a native KiCad CPU rendering of the saved compact v5 board, with copper and silkscreen. The fan/heatsink assembly is not shown in this bare-board image. The retained assembly has a separate linked review below.
## Implemented and checked
- Cropped the PCB outline to the 72 mm target and moved the upper machine pins to the matching 64 mm span.
- Moved USB-C down the same board edge to clear the upper-right machine pin.
- Added a keyed four-wire fan header, open-drain PWM driver, pull-up/pull-down network and dedicated PWM test point.
- Connected previously unused STM32 PA8 to the fan PWM circuit.
- Native schematic export matches all 288 connected logical PCB pins across 112 references.
- Native refill/save/reload preserved 2,308 track, via and pad net assignments.
- The subsequent routed checkpoint passes native DRC with zero errors and zero missing connections after repairing ground connectivity. The subsequent placement tidy removes obsolete corner-border strokes and clears Q5 from J9’s courtyard; the latest v4 cleanup now has zero errors, zero warnings and zero unconnected items. It removes the obsolete fan-supply stub and resolves project-local libraries. V5 now relocates J7 onto the front access bank, detours the PWM trace locally and updates the R11 labels; it also has zero native errors, warnings and opens. V5 is adopted into AIFlow; the fresh current screen passes and cooling acceptance remains open.
- Variable tach telemetry passes wrap, glitch, stale and slow-speed load-refusal tests. A mixed-speed transition test retains the original 15 ms stale bound at load-qualified reported speeds. All 240 synthetic shutdown scheduler cases pass. These are software tests, not hardware timing measurements.
[Machine-readable progress evidence](../../revisions/compact-r11/evidence/progress-review.json) · [Native netlist parity](../../revisions/compact-r11/evidence/v5-netlist-parity.json) · [Latest candidate native DRC](../../revisions/compact-r11/evidence/compact-sidefan-v5-native-drc.json)
## Latest verification
All 112 placements now match the saved PCB in a native live-editor check. All 95 modeled references resolve; 17 bare/mechanical features require no component body. The expanded test plan maps all 18 measurements to accessible board-level points, including PWM, tach and temperature. Assembled cooler/probe access remains a separate unfinished gate.
The fan runtime test confirms off-pose stability, rotor-only motion, fixed housing and a pause for invalid telemetry. A reviewed 31.8-second Pup clip captures the illustrative speed ramp and orbit. This is model-review footage, not measured fan motion.

[Fan wiring and motion notes](../../revisions/compact-r11/fan-assembly-notes.md) · [Prepared physical cooling test procedure](../../revisions/compact-r11/cooling-fixture-procedure.md)
## Electrical and probe evidence
The fresh v5 filled-copper solve passes its 0.1 mm current screen, including explicit terminal and plated-barrel checks. This is a computed engineering screen, not physical qualification. All 112 v5 placements match the isolated native editor, and the exact 288-pin schematic parity passes.
**Corrected probe screening:** the old checker incorrectly selected a 4 × 4 mm PCB corner as the whole board and omitted large obstacles. Its earlier clearance claim was withdrawn. The isolated repair includes the full board, large cooling bodies and the complete moving head. The original cooler placement then failed with 24 collision episodes and six snags.
V5 uses a side-fan reservation and a 90-degree scaffold orientation, with J7 moved to local (10,4) mm on the original grid. A fresh 231.7-second replay using the actual v5 board has zero collision episodes and zero tether snags. This is **main-body envelope screening only**: mounting ears, clamp, duct, sensor and fan harness remain absent. [Repair and replay evidence](../../revisions/compact-r11/probing-checker-repair.md).
Published component pages now include the [fan](https://wiki.adom.inc/adom/cfm-4010-03-22), [board header](https://wiki.adom.inc/adom/bm04b-ghs-tbt) and [cable housing](https://wiki.adom.inc/adom/ghr-04v-s). The fan runtime supports rotor-only RPM motion; animation is illustrative telemetry, not measured fan behavior.
[Q1 package-path sensitivity review](../../revisions/compact-r11/thermal-v5-review.md) explains why PCB-only heating overstated the temperature around the rectifier, and why the final thermal gate is still open.
## Cooling under review
The working heatsink is the ATS-FPX040040035-66-C2-R0, 40 × 40 × 35 mm, with a 45 × 45 mm hole pattern. The working fan is the Same Sky CFM-4010-03-22, 40 × 40 × 10.6 mm, with tach and PWM leads. Procurement snapshots are $6.82 and $10.82 respectively, excluding clamp, insulation, connector, mounting hardware, shipping and tax.
[Exact source and limitations](../../revisions/compact-r11/sourcing/selection.md). Manufacturer STEP was obtained for the fan. The heatsink CAD link requires a manufacturer login; detailed fin geometry is not yet verified. Catalog ducted resistance does not establish installed airflow or the localized Q1 thermal path. No higher wattage is released.
## Remaining gates
Physical cooling/interface/fan validation and the original AIFlow thermal/final-release gates remain open. Assumed retained assembly, output-locked PWM firmware, PCB fabrication review exports and the4:09 film are now published. Complete assembly replay is being finalized; inspect its input-bound result rather than the earlier body-only pass. The earlier concept thermal solve and R10 probe replay do not qualify this revision.
## Recording
Six individually narrated and captioned [review clips are ready](video-review.md): compact board, fan states, Q1 heat path, the failed clearance layout, the revised side-fan arrangement and fresh current results. All six have caption timing within their media and no detected silence of 0.7 seconds or longer. The thermal scene is an authored chart; the others identify their recorded or saved-result origin. Blank native-editor takes are excluded. All six R11 clips are approved and included in the published4:09 progression film. New assembly footage remains separate for review.
[Completion plan](../completion-plan.md) · [Previous design and video](../../README.md)
## Latest v5 engineering evidence

All 18 planned board measurements have landings. Fresh model resolution finds 95 component models and 17 intentionally bare features; all offline orientation checks now resolve, including J9 after its local model copy was hash-matched to the native desktop model. The nominal cooling-body replay and margins pass; that historical check does not include the newer retained assembly.
The isolated R11 STM32 bring-up image compiles with PA8 explicitly releasing the fan PWM input high during startup and fault handling. Load output is permanently locked off. Variable PWM frequency and zero-duty behavior remain unqualified; no hardware was flashed.
Six individual narrated/captioned progression scenes are prepared for storyboard review, including the revised side-fan arrangement. The six scenes are approved and assembled into the4:09 progression film; newer assembly footage is separate. Blank native-editor recordings are excluded, not presented as successful editing footage.
## Assumption-based assembly iteration
[Current mechanical and build-package review](/adom/adom-custom-electronic-load/files/revisions/compact-r11/assumed-assembly/README.md). This work proceeds under the user-authorized assumptions; it does not pass thermal or manufacturing qualification.
[Combined 4:09 design-progression film](/adom/adom-custom-electronic-load/files/docs/compact-r11/process-progression.md) combines earlier R10 footage with the six approved R11 clips.
## Prototype specification
[Current R11 prototype datasheet](../../revisions/compact-r11/assumed-assembly/prototype-datasheet.md) records command limits, interfaces, package dimensions and qualification boundaries.