markdown

0805L005

LUTE · Resettable Fuses · 0805

0805L005 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (25℃ still air) I hold 0.05 A 25℃ still air; max current that does not trip 1
Trip current (25℃ still air) I trip 0.15 A 25℃ still air; min current that trips 1
Maximum fault current I max 40 A at rated voltage (V max) 1
Power dissipated in tripped state P d 0.5 W tripped state, 25℃ still air 1
Maximum time to trip T trip 1.5 s at 0.50 A assigned current 1
Minimum initial resistance (un-soldered) R min 1.5 Ω initial, before soldering 1
Maximum resistance after trip or reflow R 1max 20 Ω 25℃, measured 1 h after tripping or reflow soldering at 260℃ for 20 s 1
Hold current derating at -40℃ I hold 0.07 A ambient operating temperature -40℃ 4
Hold current derating at -20℃ I hold 0.06 A ambient operating temperature -20℃ 4
Hold current derating at 0℃ I hold 0.055 A ambient operating temperature 0℃ 4
Hold current derating at 25℃ I hold 0.05 A ambient operating temperature 25℃ 4
Hold current derating at 40℃ I hold 0.04 A ambient operating temperature 40℃ 4
Hold current derating at 50℃ I hold 0.035 A ambient operating temperature 50℃ 4
Hold current derating at 60℃ I hold 0.03 A ambient operating temperature 60℃ 4
Hold current derating at 70℃ I hold 0.025 A ambient operating temperature 70℃ 4
Hold current derating at 85℃ I hold 0.015 A ambient operating temperature 85℃ 4
Resistance change, passive aging -5 5 % +85℃, 1000 hours; typical 4
Resistance change, humidity aging -5 5 % +85℃, 85% R.H., 168 hours; typical 4
Resistance change, thermal shock -33 33 % +85℃ to -40℃, 20 cycles; typical 4
Ambient operating temperature TA -40 85 ℃ operating 4
Maximum surface temperature in tripped state 125 ℃ device in tripped state 4
Storage temperature TSTORE 0 30 ℃ storage, 30%-60% RH 6
Peak reflow temperature Tp 260 ℃ Pb-free reflow; time within 5℃ of peak 20-40 s 6

CAD (KiCad official)

  • Symbol: 0805L005
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 02a164fafb86ec79, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF