3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdown0805L005
LUTE · Resettable Fuses · 0805
0805L005 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current (25℃ still air) | I hold | 0.05 | A | 25℃ still air; max current that does not trip | 1 | ||
| Trip current (25℃ still air) | I trip | 0.15 | A | 25℃ still air; min current that trips | 1 | ||
| Maximum fault current | I max | 40 | A | at rated voltage (V max) | 1 | ||
| Power dissipated in tripped state | P d | 0.5 | W | tripped state, 25℃ still air | 1 | ||
| Maximum time to trip | T trip | 1.5 | s | at 0.50 A assigned current | 1 | ||
| Minimum initial resistance (un-soldered) | R min | 1.5 | Ω | initial, before soldering | 1 | ||
| Maximum resistance after trip or reflow | R 1max | 20 | Ω | 25℃, measured 1 h after tripping or reflow soldering at 260℃ for 20 s | 1 | ||
| Hold current derating at -40℃ | I hold | 0.07 | A | ambient operating temperature -40℃ | 4 | ||
| Hold current derating at -20℃ | I hold | 0.06 | A | ambient operating temperature -20℃ | 4 | ||
| Hold current derating at 0℃ | I hold | 0.055 | A | ambient operating temperature 0℃ | 4 | ||
| Hold current derating at 25℃ | I hold | 0.05 | A | ambient operating temperature 25℃ | 4 | ||
| Hold current derating at 40℃ | I hold | 0.04 | A | ambient operating temperature 40℃ | 4 | ||
| Hold current derating at 50℃ | I hold | 0.035 | A | ambient operating temperature 50℃ | 4 | ||
| Hold current derating at 60℃ | I hold | 0.03 | A | ambient operating temperature 60℃ | 4 | ||
| Hold current derating at 70℃ | I hold | 0.025 | A | ambient operating temperature 70℃ | 4 | ||
| Hold current derating at 85℃ | I hold | 0.015 | A | ambient operating temperature 85℃ | 4 | ||
| Resistance change, passive aging | -5 | 5 | % | +85℃, 1000 hours; typical | 4 | ||
| Resistance change, humidity aging | -5 | 5 | % | +85℃, 85% R.H., 168 hours; typical | 4 | ||
| Resistance change, thermal shock | -33 | 33 | % | +85℃ to -40℃, 20 cycles; typical | 4 | ||
| Ambient operating temperature | TA | -40 | 85 | ℃ | operating | 4 | |
| Maximum surface temperature in tripped state | 125 | ℃ | device in tripped state | 4 | |||
| Storage temperature | TSTORE | 0 | 30 | ℃ | storage, 30%-60% RH | 6 | |
| Peak reflow temperature | Tp | 260 | ℃ | Pb-free reflow; time within 5℃ of peak 20-40 s | 6 |
CAD (KiCad official)
- Symbol:
0805L005 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
02a164fafb86ec79, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).