by John Lauer
Wi-Fi HaLow gate controller with isolated opener commands, position sensing, and a solar-battery input.
7e8a916
Design validation
The saved KiCad 10.0.8 board has filled copper pours, zero DRC errors, zero DRC warnings, zero unconnected items, and zero schematic parity findings. Schematic ERC reports zero violations. The design has 11 edge machine contacts and four grounded corner pins.
The RF trunk uses 1.23 mm front copper and a nominal 0.20 mm coplanar ground gap with a stitched rear ground reference. The 1.6 mm stackup assumes 35 µm copper, a 1.53 mm dielectric separation and relative permittivity 4.5. The closed-form routing screen passed at 50 Ω ±10% with the documented short package launches and optional unpopulated shunts. Confirm the production stackup with the fabricator and measure the prototype feed with conducted RF equipment.
Power validation uses a 1.55 A 3.3 V capability case, including 0.50 A for the main radio rail and 1.00 A for the transmitter rail. The input current estimate at 9 V and 85% conversion efficiency is 0.68 A. The regulator's exposed pad has 20 plated thermal holes. Values are design estimates and no physical build has been run.
Adom Fields converged on eight current paths at 0.25 mm resolution. In the 1.55 A case it estimated 43 mV drop on the 3.3 V supply (1.3% against a 1.0% budget) and 12.1 mV offset across the ground copper (10 mV budget). The worst modeled copper current density was 220 A/mm² on the protected battery input. Total copper loss was 0.108 W, down from 0.266 W before the wider 3.3 V and switch-node routing. The 3.3 V current-density peak was 103 A/mm² against the 60 A/mm² screen.
The thermal model assigned 0.92 W of converter loss to the regulator. It estimated a regulator rise of 35 °C, a 60 °C peak rise in still air, and a 53 °C peak rise in moving air. Both peak values exceed the 50 °C design budget. A finer 0.20 mm solve estimated 46 mV of rail drop and 61 °C of peak rise in still air. Measure rail sag and local temperature at maximum expected load and enclosure ambient before installation.
The layout review sums 30.7 mm of switch-node trace objects against its 12 mm screen. That sum includes overlapping tracks and individual pin fan-outs. The wide regulator-to-inductor path is approximately 6.7 mm. Check switch-node ringing and emissions on the prototype.
The 3D pipeline flags a machine-pin height difference between the imported attachment metadata (2.8 mm) and the model (4.216 mm). Check pin protrusion and seating on the prototype.
Field maps
# Design validation
The saved KiCad 10.0.8 board has filled copper pours, zero DRC errors, zero DRC warnings, zero unconnected items, and zero schematic parity findings. Schematic ERC reports zero violations. The design has 11 edge machine contacts and four grounded corner pins.
The RF trunk uses 1.23 mm front copper and a nominal 0.20 mm coplanar ground gap with a stitched rear ground reference. The 1.6 mm stackup assumes 35 µm copper, a 1.53 mm dielectric separation and relative permittivity 4.5. The closed-form routing screen passed at 50 Ω ±10% with the documented short package launches and optional unpopulated shunts. Confirm the production stackup with the fabricator and measure the prototype feed with conducted RF equipment.
Power validation uses a 1.55 A 3.3 V capability case, including 0.50 A for the main radio rail and 1.00 A for the transmitter rail. The input current estimate at 9 V and 85% conversion efficiency is 0.68 A. The regulator's exposed pad has 20 plated thermal holes. Values are design estimates and no physical build has been run.
Adom Fields converged on eight current paths at 0.25 mm resolution. In the 1.55 A case it estimated 43 mV drop on the 3.3 V supply (1.3% against a 1.0% budget) and 12.1 mV offset across the ground copper (10 mV budget). The worst modeled copper current density was 220 A/mm² on the protected battery input. Total copper loss was 0.108 W, down from 0.266 W before the wider 3.3 V and switch-node routing. The 3.3 V current-density peak was 103 A/mm² against the 60 A/mm² screen.
The thermal model assigned 0.92 W of converter loss to the regulator. It estimated a regulator rise of 35 °C, a 60 °C peak rise in still air, and a 53 °C peak rise in moving air. Both peak values exceed the 50 °C design budget. A finer 0.20 mm solve estimated 46 mV of rail drop and 61 °C of peak rise in still air. Measure rail sag and local temperature at maximum expected load and enclosure ambient before installation.
The layout review sums 30.7 mm of switch-node trace objects against its 12 mm screen. That sum includes overlapping tracks and individual pin fan-outs. The wide regulator-to-inductor path is approximately 6.7 mm. Check switch-node ringing and emissions on the prototype.
The 3D pipeline flags a machine-pin height difference between the imported attachment metadata (2.8 mm) and the model (4.216 mm). Check pin protrusion and seating on the prototype.
## Field maps
- [Copper current density](../images/analysis/current-density.png)
- [Copper heat flow](../images/analysis/heat-flow.png)
- [Temperature rise in still and moving air](../images/analysis/temperature-rise.png)