by John Lauer
Wi-Fi HaLow gate controller with isolated opener commands, position sensing, and a solar-battery input.
← Commit history
Add the measured numerical field-solver results and plots
4 files changed
+8−2
docs/validation.md+8−2@@ -6,10 +6,16 @@ The RF trunk uses 1.23 mm front copper and a nominal 0.20 mm coplanar ground gap Power validation uses a 1.55 A 3.3 V capability case, including 0.50 A for the main radio rail and 1.00 A for the transmitter rail. The input current estimate at 9 V and 85% conversion efficiency is 0.68 A. The regulator's exposed pad has 20 plated thermal holes. Values are design estimates and no physical build has been run. -Adom Fields converged on eight current paths at 0.25 mm resolution. In the 1.55 A case it estimated 43 mV drop on the 3.3 V supply (1.3% against a 1.0% budget) and 12.1 mV offset across the ground copper (10 mV budget). The worst modeled copper current density was 220 A/mm² on the protected battery input. Total copper loss was 0.108 W, down from 0.266 W before the wider 3.3 V and switch-node routing.+Adom Fields converged on eight current paths at 0.25 mm resolution. In the 1.55 A case it estimated 43 mV drop on the 3.3 V supply (1.3% against a 1.0% budget) and 12.1 mV offset across the ground copper (10 mV budget). The worst modeled copper current density was 220 A/mm² on the protected battery input. Total copper loss was 0.108 W, down from 0.266 W before the wider 3.3 V and switch-node routing. The 3.3 V current-density peak was 103 A/mm² against the 60 A/mm² screen. -The thermal model assigned 0.92 W of converter loss to the regulator. It estimated a regulator rise of 35 °C, a 60 °C peak rise in still air, and a 53 °C peak rise in moving air. Both peak values exceed the 50 °C design budget. Measure rail sag and local temperature at maximum expected load and enclosure ambient before installation.+The thermal model assigned 0.92 W of converter loss to the regulator. It estimated a regulator rise of 35 °C, a 60 °C peak rise in still air, and a 53 °C peak rise in moving air. Both peak values exceed the 50 °C design budget. A finer 0.20 mm solve estimated 46 mV of rail drop and 61 °C of peak rise in still air. Measure rail sag and local temperature at maximum expected load and enclosure ambient before installation. The layout review sums 30.7 mm of switch-node trace objects against its 12 mm screen. That sum includes overlapping tracks and individual pin fan-outs. The wide regulator-to-inductor path is approximately 6.7 mm. Check switch-node ringing and emissions on the prototype. The 3D pipeline flags a machine-pin height difference between the imported attachment metadata (2.8 mm) and the model (4.216 mm). Check pin protrusion and seating on the prototype.++## Field maps++- [Copper current density](../images/analysis/current-density.png)+- [Copper heat flow](../images/analysis/heat-flow.png)+- [Temperature rise in still and moving air](../images/analysis/temperature-rise.png)
images/analysis/current-density.pngadded⋯ 1 unchanged line ⋯
images/analysis/heat-flow.pngadded⋯ 1 unchanged line ⋯
images/analysis/temperature-rise.pngadded⋯ 1 unchanged line ⋯