← Commit history

Set visibility: public

Ray ·fb74cd4f27 · ·parent a67228d
1 file changed +12−9
page.json+12−9
@@ -124,19 +124,19 @@         "number": "13",         "name": "VREF",         "type": "power_out",-        "description": "1.7-V, 500-\u00b5A, LDO reference voltage output; bypass to GND with 0.33 \u00b5F capacitor; connect to REFIN of TI power stages as current-sense reference."+        "description": "1.7-V, 500-µA, LDO reference voltage output; bypass to GND with 0.33 µF capacitor; connect to REFIN of TI power stages as current-sense reference."       },       {         "number": "14",         "name": "V3R3",         "type": "power_out",-        "description": "3.3-V LDO output from V5; bypass to GND with 1-\u00b5F or larger ceramic capacitor; powers internal digital circuits and provides pull-up source for open-drain outputs."+        "description": "3.3-V LDO output from V5; bypass to GND with 1-µF or larger ceramic capacitor; powers internal digital circuits and provides pull-up source for open-drain outputs."       },       {         "number": "15",         "name": "V5",         "type": "power_in",-        "description": "5-V power input; bypass to GND with 1-\u00b5F or larger ceramic capacitor; supplies all internal analog circuits; rated 4.5 V to 5.5 V operating range."+        "description": "5-V power input; bypass to GND with 1-µF or larger ceramic capacitor; supplies all internal analog circuits; rated 4.5 V to 5.5 V operating range."       },       {         "number": "16",@@ -154,13 +154,13 @@         "number": "18",         "name": "VR_RDY",         "type": "tri_state",-        "description": "Power good open-drain output; typically pulled up to V3R3 through 3-k\u03a9 or larger resistor; asserts high when output voltage in regulation within UVP/OVP thresholds."+        "description": "Power good open-drain output; typically pulled up to V3R3 through 3-kΩ or larger resistor; asserts high when output voltage in regulation within UVP/OVP thresholds."       },       {         "number": "19",         "name": "VR_HOT",         "type": "tri_state",-        "description": "Thermal flag open-drain output, active low; typically pulled up to V3R3 through 3-k\u03a9 or larger resistor; asserts low when sensed temperature exceeds 110\u00b0C default warning threshold."+        "description": "Thermal flag open-drain output, active low; typically pulled up to V3R3 through 3-kΩ or larger resistor; asserts low when sensed temperature exceeds 110°C default warning threshold."       },       {         "number": "20",@@ -220,7 +220,7 @@         "number": "29",         "name": "SLEW-MODE",         "type": "input",-        "description": "Voltage divider to VREF pin; resistor (RSLEW-MODE) to GND selects output voltage change slew rate (0.34 to 2.74 mV/\u00b5s); voltage sets 4-bit operation mode bits for DAC mode, phase interleaving, dynamic phase shedding, and zero load-line."+        "description": "Voltage divider to VREF pin; resistor (RSLEW-MODE) to GND selects output voltage change slew rate (0.34 to 2.74 mV/µs); voltage sets 4-bit operation mode bits for DAC mode, phase interleaving, dynamic phase shedding, and zero load-line."       },       {         "number": "30",@@ -238,7 +238,7 @@         "number": "32",         "name": "F-IMAX",         "type": "input",-        "description": "Voltage divider to VREF pin; resistor (RF-IMAX) to GND sets switching frequency from 300 kHz to 1 MHz; voltage sets maximum operating current (IMAX) with 8-bit A/D where IMAX = (VF-IMAX/VREF) \u00d7 256 - 0.5."+        "description": "Voltage divider to VREF pin; resistor (RF-IMAX) to GND sets switching frequency from 300 kHz to 1 MHz; voltage sets maximum operating current (IMAX) with 8-bit A/D where IMAX = (VF-IMAX/VREF) × 256 - 0.5."       },       {         "number": "33",@@ -286,7 +286,7 @@         "number": "40",         "name": "TSEN",         "type": "input",-        "description": "Temperature sense input; connect to TAO/FAULT pin of TI smart power stages to sense highest die temperature and power stage fault signals; 0\u00b0C to 127.9\u00b0C measurement range."+        "description": "Temperature sense input; connect to TAO/FAULT pin of TI smart power stages to sense highest die temperature and power stage fault signals; 0°C to 127.9°C measurement range."       },       {         "number": "41",@@ -373,5 +373,8 @@     "docs/tps53647rtar-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file