main
John Lauer Orient the component display Z-up while preserving manufacturer geometry fbcd234 29d ago
{
  "source_glb": "DSE0006A.glb",
  "source_sha256": "208a8a523792ea330c633b25699177cedbcaafb09e30ce0fbbfb15d110c392fe",
  "derivative": "DSE0006A.adom-zup.glb",
  "derivative_sha256": "3ab9b63d93826926ca0940119476de4ed15178c741ad4f7b3ce78b546045fa82",
  "source_step_sha256": "14a47e7abf178da4755a4bbc05c724ca531edd590029a97fa11f6ac0e67ff166",
  "units": "metre",
  "quaternion_xyzw": [
    0.5,
    0.5,
    0.5,
    0.5
  ],
  "translation_m": [
    0,
    0,
    2.5e-05
  ],
  "axis_mapping": "Adom X=source Z; Adom Y=source X; Adom Z=source Y + 0.025 mm",
  "geometry_buffers": "byte-identical",
  "target_viewer": "right handed; camera up=(0,0,1); zUp:true, verified live",
  "expected_physical_bounds_mm": {
    "min": [
      -0.75,
      -0.75,
      0
    ],
    "max": [
      0.75,
      0.75,
      0.8
    ]
  },
  "validation_limits": [
    "Display pose correction only; not native footprint placement qualification.",
    "Original STEP leads are 0.05 mm shorter than drawing minimum; no scaling or geometry repair performed.",
    "Virtual MPN marking not added."
  ]
}