Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

MX25U25645GMI00

MXIC(Macronix) · Pre-ordered Products · SOIC-16-300mil

MX25U25645GMI00 from MXIC(Macronix), in a SOIC-16-300mil. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 NC/SIO3 bidirectional No connection, or serial data input and output (SIO3) in 4xI/O read mode when Quad is enabled (depends on part number options).
2 VCC power_in Power supply.
3 RESET# input Hardware reset pin, active low; has an internal pull-up when not physically connected.
4 NC unconnected No connection.
5 DNU unconnected Do not use; it may connect to an internal signal inside the device.
6 DNU unconnected Do not use; it may connect to an internal signal inside the device.
7 CS# input Chip select; enables serial access to the device, and the device is in standby when CS# is high and not in operation.
8 SO/SIO1 bidirectional Serial data output in 1xI/O mode, or serial data input and output in 2xI/O or 4xI/O read mode.
9 WP#/SIO2 bidirectional Write protection, active low, or serial data input and output (SIO2) in 4xI/O read mode; has an internal pull-up when not physically connected.
10 GND power_in Ground.
11 DNU unconnected Do not use; it may connect to an internal signal inside the device.
12 DNU unconnected Do not use; it may connect to an internal signal inside the device.
13 NC unconnected No connection.
14 NC unconnected No connection.
15 SI/SIO0 bidirectional Serial data input in 1xI/O mode, or serial data input and output in 2xI/O or 4xI/O read mode.
16 SCLK input Clock input.

Key specifications

Parameter Value
Manufacturer MXIC(Macronix)
Package SOIC-16-300mil
Category Electronic Tools/Instruments/Consumables
Pins 16

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
VCC Power Supply VCC 1.65 2 V read, erase, program 120
Input Load Current ILI -2 2 uA VCC = VCC Max, VIN = VCC or GND 115
Output Leakage Current ILO -2 2 uA VCC = VCC Max, VOUT = VCC or GND 115
VCC Standby Current ISB1 20 180 uA VIN = VCC or GND, CS# = VCC 115
Deep Power-down Current ISB2 50 uA VIN = VCC or GND, CS# = VCC 115
VCC Read Current ICC1 25 35 mA f=100MHz (DTR 4 x I/O read), SCLK=0.1VCC/0.9VCC, SO=Open 115
VCC Read Current ICC1 22 30 mA f=133MHz (4 x I/O read), SCLK=0.1VCC/0.9VCC, SO=Open 115
VCC Read Current ICC1 18 25 mA f=104MHz (4 x I/O read), SCLK=0.1VCC/0.9VCC, SO=Open 115
VCC Read Current ICC1 13 16 mA f=84MHz, SCLK=0.1VCC/0.9VCC, SO=Open 115
VCC Program Current (PP) ICC2 30 40 mA Program in Progress, CS# = VCC 115
VCC Write Status Register Current ICC3 20 40 mA Program status register in progress, CS#=VCC 115
VCC Sector/Block Erase Current ICC4 30 40 mA Erase in Progress, CS#=VCC 115
VCC Chip Erase Current ICC5 20 40 mA Erase in Progress, CS#=VCC 115
Input Low Voltage (min; max is 0.3VCC) VIL -0.4 V max printed as 0.3VCC 115
Output Low Voltage VOL 0.2 V IOL = 100uA 115
Ambient Operating Temperature -40 85 °C Industrial grade 113
Storage Temperature -65 150 °C 113
VCC to Ground Potential -0.5 2.5 V 113
Applied Input Voltage (min; max is VCC+0.5V) -0.5 V max printed as VCC+0.5V 113
Applied Output Voltage (min; max is VCC+0.5V) -0.5 V max printed as VCC+0.5V 113
Input Capacitance CIN 8 pF VIN = 0V, TA = 25°C, f = 1.0 MHz 113
Output Capacitance COUT 8 pF VOUT = 0V, TA = 25°C, f = 1.0 MHz 113
Clock Frequency for all commands (except Read) fSCLK 0 166 MHz min printed as D.C. 116
Clock Frequency for READ instructions fRSCLK 66 MHz 116
Clock High Time Normal Read tCH 7 ns Normal Read (fRSCLK) 116
Clock Low Time Normal Read tCL 7 ns Normal Read (fRSCLK) 116
Clock Rise Time (peak to peak) tCLCH 0.1 V/ns 116
Clock Fall Time (peak to peak) tCHCL 0.1 V/ns 116
CS# Active Setup Time tSLCH 3 ns relative to SCLK 116
CS# Not Active Hold Time tCHSL 4 ns relative to SCLK 116
Data In Setup Time STR tDVCH 2 ns STR 116
Data In Setup Time DTR tDVCL 2 ns DTR 116
Data In Hold Time STR tCHDX 2 ns STR 116
Data In Hold Time DTR tCLDX 2 ns DTR 116
CS# Active Hold Time tCHSH 3 ns relative to SCLK 116
CS# Not Active Setup Time tSHCH 3 ns relative to SCLK 116
CS# Deselect Time Read to Read tSHSL 7 ns From Read to next Read 116
CS# Deselect Time Write/Erase/Program to Read Status tSHSL 30 ns From Write/Erase/Program to Read Status Register 116
Output Disable Time tSHQZ 8 ns 116
Clock Low to Output Valid tCLQV 5 ns 16-SOP, Loading: 30pF 116
Clock Low to Output Valid tCLQV 4.5 ns 16-SOP, Loading: 15pF 116
Clock Low to Output Valid tCLQV 4 ns 16-SOP, Loading: 10pF 116
Output Hold Time tCLQX 1 ns 116
Write Protect Setup Time tWHSL 20 ns 116
Write Protect Hold Time tSHWL 100 ns 116
CS# High to Deep Power-down Mode tDP 10 us 116
CS# High to Standby Mode without Electronic Signature Read tRES1 30 us 116
CS# High to Standby Mode with Electronic Signature Read tRES2 30 us 116
Write Status/Configuration Register Cycle Time tW 40 ms 116
Write Extended Address Register tWREAW 40 ns 116
Byte-Program Time tBP 25 60 us 116
Page Program Cycle Time tPP 0.15 0.75 ms 116
Sector Erase Cycle Time tSE 25 400 ms 116
Block Erase (32KB) Cycle Time tBE32 150 1000 ms 116
Block Erase (64KB) Cycle Time tBE 220 1300 ms 116
Chip Erase Cycle Time tCE 75 150 s 116
Erase Suspend Latency tESL 25 us 117
Program Suspend Latency tPSL 25 us 117
Latency between Program Resume and next Suspend tPRS 0.3 100 us 117
Latency between Erase Resume and next Suspend tERS 0.3 400 us 117
VCC Rise Time tVR 500000 us/V 118
VCC voltage needed to be below VPWD for initialization VPWD 0.8 V 120
Voltage for re-initialization if VDD drops below V_keep 1.5 V 120
Minimum duration for ensuring initialization tPWD 300 us 120
VCC(min.) to device operation tVSL 1500 us 120
Write Inhibit Voltage VWI 1 1.5 V 120

CAD (KiCad official)

  • Symbol: MX25U25645GMI00
  • Footprint: Package_SO:SOIC-16_3.9x9.9mm_P1.27mm
  • 3D model: SOIC-16-300mil (KiCad packages3D, STEP)
  • 3D model files: mx25u25645gmi00-etched.step / mx25u25645gmi00-etched.glb carry the MPN laser-etched on the die in a toggleable Adom.LaserEtch group (Fusion-ready); mx25u25645gmi00.step / mx25u25645gmi00.glb are the bare package body.

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: MXIC(Macronix) datasheet (130 pp, sha256 87d9b4345e891239, retrieved 2026-10-23, tier: lcsc)
  • Extractor: parts-factory 2.0.0 / extract_pins 0.3, primary claude-sonnet-5-5 (text), consensus claude-sonnet-5-5 (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF