component
MAX6700UT+T
Public Made by Adomby adom
Maxim Integrated Monitors & Reset Circuits, SOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
main
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182
{
"slug": "max6700ut-t",
"version": "0.1.0",
"type": "component",
"description": "Maxim Integrated Monitors & Reset Circuits, SOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"tags": [
"component",
"power management ics",
"max6700ut+t",
"factory-2.0.0",
"extractor-text"
],
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"max6700ut-t.kicad_sym",
"max6700ut-t.kicad_mod",
"max6700ut-t.glb",
"max6700ut-t.step",
"max6700ut-t.lbr",
"docs/hero.png",
"docs/max6700ut-t-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"max6700ut-t-hero.glb",
"max6700ut-t-hero.overlay.json",
"max6700ut-t-etched.glb"
],
"component": {
"mpn": "MAX6700UT+T",
"manufacturer": "Maxim Integrated",
"package": "SOT-23-6",
"pin_count": 6,
"category": "Power Management ICs",
"subcategory": "Monitors & Reset Circuits",
"datasheet": "https://www.analog.com/media/en/technical-documentation/data-sheets/max6700-max6710.pdf",
"parts": {
"symbol": "max6700ut-t.kicad_sym",
"footprint": "max6700ut-t.kicad_mod",
"model_3d": "max6700ut-t-hero.glb",
"model_3d_plain": "max6700ut-t-etched.glb",
"model_3d_step": "max6700ut-t-etched.step",
"model_3d_step_plain": "max6700ut-t.step",
"lbr": "max6700ut-t.lbr"
},
"distributor_links": {
"lcsc": "C2067083",
"digikey": "MAX6700UT+TTR-ND",
"mouser": "700-MAX6700UTT"
},
"distributor_check": {
"checked_at": "2026-10-30T23:48:22Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "MAX6700UT+TTR-ND",
"status": "found"
},
"mouser": {
"pn": "700-MAX6700UTT",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "IN1",
"type": "input",
"description": "Adjustable voltage monitor input with a typical 0.62V threshold set by an external resistor divider, guaranteed input current of ±0.4µA, and RESET asserts low when it falls below its threshold."
},
{
"number": "2",
"name": "VCC",
"type": "power_in",
"description": "On the MAX6700UT this pin is the VCC power-supply input (not a monitored voltage), specified from 2.0V to 5.5V, and RESET remains valid while VCC is above 2V."
},
{
"number": "3",
"name": "IN3",
"type": "input",
"description": "Adjustable voltage monitor input with a typical 0.62V threshold set by an external resistor divider and guaranteed input current of ±0.2µA; unused monitor inputs must not be grounded or left floating."
},
{
"number": "4",
"name": "IN4",
"type": "input",
"description": "Adjustable voltage monitor input with a typical 0.62V threshold set by an external resistor divider and guaranteed input current of ±0.2µA; unused monitor inputs must not be grounded or left floating."
},
{
"number": "5",
"name": "GND",
"type": "power_in",
"description": "Ground reference for the device."
},
{
"number": "6",
"name": "RESET",
"type": "output",
"description": "Active-low open-drain reset output that goes low when any monitored input is below its threshold and stays low for the 5µs propagation delay after all inputs exceed their thresholds (MAX6700), with a weak 10µA internal pullup to VCC."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-haiku-5-5",
"primary_mode": "text",
"consensus_model": "claude-sonnet-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: Pin 2 is printed as IN2 on the package and pin table, but for the MAX6700UT the Selector Guide lists; RESET is an open-drain output. The ERC enum has no open-drain class, so it is typed as output; the o; The Pin Configuration drawing on page 8 is garbled in the text extraction. Pin numbers were taken fr"
],
"pages_sent": 10,
"cost_usd": 0.051,
"at": "2026-10-30T23:48:15"
},
"datasheet": {
"url": "https://www.analog.com/media/en/technical-documentation/data-sheets/max6700-max6710.pdf",
"pages": 10,
"sha256": "73c4b80c4cbe240d",
"source_tier": "mfr"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 6,
"described": 6,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "max6700ut-t.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2.8,
2.9,
1.55
],
"zmin_mm": 0.0,
"centre_offset_mm": 0.0,
"footprint_binding": "identity",
"sha256": "c9fe686b4d1b56927a41fa84a9bc1efb61d8a45a123a3db43bcaa05c2891d635",
"checked": "2026-10-30",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "max6700ut-t-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2.8,
2.9,
1.55
],
"zmin_mm": 0.0,
"centre_offset_mm": 0.0,
"footprint_binding": "identity",
"sha256": "6c83cd65e19e3c864ca1e267e60f0699cceb47f20c2db5f5bc3748d55d7ff11f",
"checked": "2026-10-30",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
}
}