← Commit history
lm51551qdssrq1: specified limits as data (metadata.characteristics, 60 rows from the datasheet)
2 files changed
+794
README.md+67@@ -31,6 +31,73 @@ LM51551QDSSRQ1 from Texas Instruments, in a WSON-12-EP(2x3). Pinout and pin desc | Category | Power Management (PMIC) | | Pins | 13 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| BIAS to AGND | | -0.3 | | 50 | V | | 5 |+| UVLO to AGND | | -0.3 | | | V | | 5 |+| SS to AGND | | -0.3 | | 3.8 | V | | 5 |+| RT to AGND | | -0.3 | | 3.8 | V | | 5 |+| FB to AGND | | -0.3 | | 3.8 | V | | 5 |+| CS to AGND | | -0.3 | | 0.3 | V | DC | 5 |+| CS to AGND | | -1 | | | V | 100ns transient | 5 |+| CS to AGND | | -2 | | | V | 20ns transient | 5 |+| PGND to AGND | | -0.3 | | 0.3 | V | | 5 |+| VCC to AGND | | -0.3 | | 18 | V | | 5 |+| GATE to AGND | | -1 | | | V | 100ns transient | 5 |+| GATE to AGND | | -2 | | | V | 50ns transient | 5 |+| PGOOD to AGND | | -0.3 | | 18 | V | | 5 |+| COMP to AGND | | -0.3 | | | V | | 5 |+| Junction temperature | TJ | -40 | | 150 | °C | | 5 |+| Storage temperature | Tstg | -55 | | 150 | °C | | 5 |+| BIAS input voltage | VBIAS | 2.97 | | 45 | V | | 6 |+| VCC voltage | VVCC | 2.97 | | 16 | V | | 6 |+| UVLO input voltage | VUVLO | 0 | | 45 | V | | 6 |+| FB input voltage | VFB | 0 | | 3.7 | V | | 6 |+| Typical switching frequency | fSW | 100 | | 2200 | kHz | | 6 |+| Synchronization pulse frequency | fSYNC | 100 | | 2200 | kHz | | 6 |+| Operating junction temperature | TJ | -40 | | 150 | °C | | 6 |+| BIAS shutdown current | ISHUTDOWN(BIAS) | | 2.6 | 5 | uA | VBIAS = 12V, VUVLO = 0V | 6 |+| BIAS operating current | IOPERATING(BIAS) | | 480 | 540 | uA | VBIAS = 12V, VUVLO = 2V, VFB = VREF, RT = 220kΩ | 6 |+| VCC regulation, no load | VVCC-REG | 6.5 | 6.85 | 7 | V | VBIAS = 8V, no load | 6 |+| VCC regulation under load | VVCC-REG | 6.5 | | | V | VBIAS = 8V, IVCC = 35mA | 6 |+| VCC UVLO threshold, rising | VVCC-UVLO(RISING) | 2.75 | 2.85 | 2.95 | V | VCC rising | 6 |+| VCC source current limit | IVCC-CL | 35 | | 105 | mA | VBIAS = 10V, VVCC = 0V | 6 |+| COMP clamp voltage, rising | | 2.5 | | 2.8 | V | COMP rising (VUVLO = 2.0V) | 7 |+| COMP clamp voltage, falling | | 1 | | 1.1 | V | COMP falling | 7 |+| EN enable threshold, rising | VEN(RISING) | 0.4 | 0.52 | 0.7 | V | EN rising | 7 |+| EN enable threshold, falling | VEN(FALLING) | 0.33 | 0.49 | 0.63 | V | EN falling | 7 |+| UVLO/SYNC threshold, rising | VUVLO(RISING) | 1.425 | 1.5 | 1.575 | V | UVLO rising | 7 |+| UVLO/SYNC threshold, falling | VUVLO(FALLING) | 1.37 | 1.45 | 1.52 | V | UVLO falling | 7 |+| UVLO hysteresis current | IUVLO | 4 | 5 | 6 | uA | VUVLO = 1.6V | 7 |+| Soft-start current | ISS | 9 | 10 | 11 | uA | | 7 |+| Switching frequency 1 | fsw1 | 85 | 100 | 115 | kHz | RT = 220kΩ | 7 |+| Switching frequency 2 | fsw2 | 1980 | 2200 | 2420 | kHz | RT = 9.09kΩ | 7 |+| Maximum duty cycle limit 1 | DMAX1 | 80 | 85 | 90 | % | RT = 9.09kΩ | 7 |+| Maximum duty cycle limit 2 | DMAX2 | 90 | 93 | 96 | % | RT = 220kΩ | 7 |+| Peak slope compensation current | ISLOPE | 22.5 | 30 | 37.5 | uA | RT = 220kΩ | 7 |+| Current limit threshold (CS-PGND) | VCLTH | 93 | 100 | 107 | mV | | 7 |+| FB reference voltage | VREF | 0.99 | 1 | 1.01 | V | LM5155, LM51551 | 7 |+| OVP threshold, FB rising (referenced to VREF) | VOVTH | 107 | 110 | 113 | % | FB rising, referenced to VREF | 7 |+| UVLO threshold, FB falling (PGOOD, referenced to VREF) | VUVTH | 87 | 90 | 93 | % | FB falling, referenced to VREF | 7 |+| Thermal shutdown threshold | TTSD | | 175 | | °C | Temperature rising | 7 |+| MOSFET driver high-state voltage drop | | | 0.25 | | V | 100mA sink | 7 |+| MOSFET driver low-state voltage drop | | | 0.15 | | V | 100mA source | 7 |+| SS pull-down switch RDSON | | | 55 | | Ω | | 7 |+| PGOOD pull-down switch RDSON | | | 90 | | Ω | 1 mA sink | 7 |+| COMP sourcing current | | | 180 | | uA | VCOMP = 1.2V | 7 |+| Minimum on-time | tON(MIN) | | 50 | | ns | RT = 9.09kΩ | 7 |+| Error amplifier transconductance | Gm | | 2 | | mA/V | | 7 |+| Intermittent mode enable period (LM51551) | | | 64 | | cycles | LM51551 intermittent-mode option | 7 |+| VCC UVLO hysteresis | | | 0.063 | | V | VCC falling | 6 |+| Junction-to-ambient thermal resistance (DSS0012C, WF) | RθJA | | 60.3 | | °C/W | | 6 |+| Junction-to-case (top) thermal resistance (DSS0012C, WF) | RθJC(top) | | 60.1 | | °C/W | | 6 |+| Junction-to-board thermal resistance (DSS0012C, WF) | RθJB | | 28.8 | | °C/W | | 6 |+| Junction-to-case (bottom) thermal resistance (DSS0012C, WF) | RθJC(bot) | | 7.1 | | °C/W | | 6 |+ ## CAD (KiCad official) - Symbol: `LM51551QDSSRQ1`
page.json+727@@ -171,6 +171,733 @@ "Package": "WSON-12-EP(2x3)", "Category": "Power Management (PMIC)", "Pins": "13"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "a8503f9fa4bec785",+ "rows": [+ {+ "name": "BIAS to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "UVLO to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SS to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 3.8,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "RT to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 3.8,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 3.8,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "CS to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 0.3,+ "conditions": "DC",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "CS to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -1,+ "typ": null,+ "max": null,+ "conditions": "100ns transient",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "CS to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -2,+ "typ": null,+ "max": null,+ "conditions": "20ns transient",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "PGND to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 0.3,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "GATE to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -1,+ "typ": null,+ "max": null,+ "conditions": "100ns transient",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "GATE to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -2,+ "typ": null,+ "max": null,+ "conditions": "50ns transient",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "PGOOD to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "COMP to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "BIAS input voltage",+ "symbol": "VBIAS",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.97,+ "typ": null,+ "max": 45,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC voltage",+ "symbol": "VVCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.97,+ "typ": null,+ "max": 16,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "UVLO input voltage",+ "symbol": "VUVLO",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 45,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "FB input voltage",+ "symbol": "VFB",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 3.7,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Typical switching frequency",+ "symbol": "fSW",+ "kind": "recommended_operating",+ "unit": "kHz",+ "min": 100,+ "typ": null,+ "max": 2200,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Synchronization pulse frequency",+ "symbol": "fSYNC",+ "kind": "recommended_operating",+ "unit": "kHz",+ "min": 100,+ "typ": null,+ "max": 2200,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "BIAS shutdown current",+ "symbol": "ISHUTDOWN(BIAS)",+ "kind": "electrical",+ "unit": "uA",+ "min": null,+ "typ": 2.6,+ "max": 5,+ "conditions": "VBIAS = 12V, VUVLO = 0V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "BIAS operating current",+ "symbol": "IOPERATING(BIAS)",+ "kind": "electrical",+ "unit": "uA",+ "min": null,+ "typ": 480,+ "max": 540,+ "conditions": "VBIAS = 12V, VUVLO = 2V, VFB = VREF, RT = 220kΩ",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC regulation, no load",+ "symbol": "VVCC-REG",+ "kind": "electrical",+ "unit": "V",+ "min": 6.5,+ "typ": 6.85,+ "max": 7,+ "conditions": "VBIAS = 8V, no load",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC regulation under load",+ "symbol": "VVCC-REG",+ "kind": "electrical",+ "unit": "V",+ "min": 6.5,+ "typ": null,+ "max": null,+ "conditions": "VBIAS = 8V, IVCC = 35mA",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC UVLO threshold, rising",+ "symbol": "VVCC-UVLO(RISING)",+ "kind": "electrical",+ "unit": "V",+ "min": 2.75,+ "typ": 2.85,+ "max": 2.95,+ "conditions": "VCC rising",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC source current limit",+ "symbol": "IVCC-CL",+ "kind": "electrical",+ "unit": "mA",+ "min": 35,+ "typ": null,+ "max": 105,+ "conditions": "VBIAS = 10V, VVCC = 0V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "COMP clamp voltage, rising",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 2.5,+ "typ": null,+ "max": 2.8,+ "conditions": "COMP rising (VUVLO = 2.0V)",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "COMP clamp voltage, falling",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 1,+ "typ": null,+ "max": 1.1,+ "conditions": "COMP falling",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "EN enable threshold, rising",+ "symbol": "VEN(RISING)",+ "kind": "electrical",+ "unit": "V",+ "min": 0.4,+ "typ": 0.52,+ "max": 0.7,+ "conditions": "EN rising",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "EN enable threshold, falling",+ "symbol": "VEN(FALLING)",+ "kind": "electrical",+ "unit": "V",+ "min": 0.33,+ "typ": 0.49,+ "max": 0.63,+ "conditions": "EN falling",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "UVLO/SYNC threshold, rising",+ "symbol": "VUVLO(RISING)",+ "kind": "electrical",+ "unit": "V",+ "min": 1.425,+ "typ": 1.5,+ "max": 1.575,+ "conditions": "UVLO rising",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "UVLO/SYNC threshold, falling",+ "symbol": "VUVLO(FALLING)",+ "kind": "electrical",+ "unit": "V",+ "min": 1.37,+ "typ": 1.45,+ "max": 1.52,+ "conditions": "UVLO falling",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "UVLO hysteresis current",+ "symbol": "IUVLO",+ "kind": "electrical",+ "unit": "uA",+ "min": 4,+ "typ": 5,+ "max": 6,+ "conditions": "VUVLO = 1.6V",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Soft-start current",+ "symbol": "ISS",+ "kind": "electrical",+ "unit": "uA",+ "min": 9,+ "typ": 10,+ "max": 11,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency 1",+ "symbol": "fsw1",+ "kind": "electrical",+ "unit": "kHz",+ "min": 85,+ "typ": 100,+ "max": 115,+ "conditions": "RT = 220kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency 2",+ "symbol": "fsw2",+ "kind": "electrical",+ "unit": "kHz",+ "min": 1980,+ "typ": 2200,+ "max": 2420,+ "conditions": "RT = 9.09kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum duty cycle limit 1",+ "symbol": "DMAX1",+ "kind": "electrical",+ "unit": "%",+ "min": 80,+ "typ": 85,+ "max": 90,+ "conditions": "RT = 9.09kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum duty cycle limit 2",+ "symbol": "DMAX2",+ "kind": "electrical",+ "unit": "%",+ "min": 90,+ "typ": 93,+ "max": 96,+ "conditions": "RT = 220kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Peak slope compensation current",+ "symbol": "ISLOPE",+ "kind": "electrical",+ "unit": "uA",+ "min": 22.5,+ "typ": 30,+ "max": 37.5,+ "conditions": "RT = 220kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold (CS-PGND)",+ "symbol": "VCLTH",+ "kind": "electrical",+ "unit": "mV",+ "min": 93,+ "typ": 100,+ "max": 107,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "FB reference voltage",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 0.99,+ "typ": 1,+ "max": 1.01,+ "conditions": "LM5155, LM51551",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "OVP threshold, FB rising (referenced to VREF)",+ "symbol": "VOVTH",+ "kind": "electrical",+ "unit": "%",+ "min": 107,+ "typ": 110,+ "max": 113,+ "conditions": "FB rising, referenced to VREF",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "UVLO threshold, FB falling (PGOOD, referenced to VREF)",+ "symbol": "VUVTH",+ "kind": "electrical",+ "unit": "%",+ "min": 87,+ "typ": 90,+ "max": 93,+ "conditions": "FB falling, referenced to VREF",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Thermal shutdown threshold",+ "symbol": "TTSD",+ "kind": "electrical",+ "unit": "°C",+ "min": null,+ "typ": 175,+ "max": null,+ "conditions": "Temperature rising",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "MOSFET driver high-state voltage drop",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.25,+ "max": null,+ "conditions": "100mA sink",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "MOSFET driver low-state voltage drop",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.15,+ "max": null,+ "conditions": "100mA source",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "SS pull-down switch RDSON",+ "symbol": "",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 55,+ "max": null,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "PGOOD pull-down switch RDSON",+ "symbol": "",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 90,+ "max": null,+ "conditions": "1 mA sink",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "COMP sourcing current",+ "symbol": "",+ "kind": "electrical",+ "unit": "uA",+ "min": null,+ "typ": 180,+ "max": null,+ "conditions": "VCOMP = 1.2V",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Minimum on-time",+ "symbol": "tON(MIN)",+ "kind": "electrical",+ "unit": "ns",+ "min": null,+ "typ": 50,+ "max": null,+ "conditions": "RT = 9.09kΩ",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Error amplifier transconductance",+ "symbol": "Gm",+ "kind": "electrical",+ "unit": "mA/V",+ "min": null,+ "typ": 2,+ "max": null,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Intermittent mode enable period (LM51551)",+ "symbol": "",+ "kind": "electrical",+ "unit": "cycles",+ "min": null,+ "typ": 64,+ "max": null,+ "conditions": "LM51551 intermittent-mode option",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "VCC UVLO hysteresis",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.063,+ "max": null,+ "conditions": "VCC falling",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance (DSS0012C, WF)",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 60.3,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (top) thermal resistance (DSS0012C, WF)",+ "symbol": "RθJC(top)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 60.1,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-board thermal resistance (DSS0012C, WF)",+ "symbol": "RθJB",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 28.8,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (bottom) thermal resistance (DSS0012C, WF)",+ "symbol": "RθJC(bot)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 7.1,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ }+ ] } }, "variants": [],