← Commit history
page.json+385−28@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "hc-gh-13plt-05",+ "title": "HC-GH-13PLT-05",+ "brief": "HCTL Wire To Board Connector, SMD,P=1.25mm. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "HCTL Wire To Board Connector, SMD,P=1.25mm. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "connectors",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "hc-gh-13plt-05.kicad_sym",- "hc-gh-13plt-05.kicad_mod",- "hc-gh-13plt-05.glb",- "hc-gh-13plt-05.step",- "hc-gh-13plt-05.lbr",- "docs/hero.png",- "docs/hc-gh-13plt-05-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "hc-gh-13plt-05-hero.glb",- "hc-gh-13plt-05-hero.overlay.json"- ], "component": { "mpn": "HC-GH-13PLT-05", "manufacturer": "HCTL",@@ -191,8 +174,8 @@ 4.95, 4.2 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "76a6fede40e3ab004998418d2bf8574f67feab915c6099d5f8bb59796b12f3c6", "checked": "2026-11-06",@@ -220,10 +203,384 @@ } } },- "visibility": "public",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "HCTL",+ "Package": "JST_GH_BM13B-GHS-TBT_1x13-1MP_P1.25mm_Vertical",+ "Category": "Connectors",+ "Pins": "13"+ },+ "appearance": {+ "housing": {+ "quote": "7、Material: Housing Nylon66 UL94-VO(2) 2 HC-GH-2Y-05 1.25 34567",+ "page": 16,+ "doc": "ds.pdf",+ "material": "Nylon"+ },+ "contacts": {+ "quote": "PIN Brass Tin-plated",+ "page": 17,+ "doc": "ds.pdf",+ "material": "Brass",+ "plating": "tin"+ },+ "version": 1,+ "datasheet_sha256": ""+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "",+ "rows": [+ {+ "name": "Rated voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "AC, DC",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Rated current",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "AC, DC",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Operating ambient temperature range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": -25,+ "typ": null,+ "max": 85,+ "conditions": "Ambient temperature range",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance (initial)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "Mate connector; max 20 mV and max 100 mA applied",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Leakage current (withstand voltage test)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 0.5,+ "conditions": "500 V AC(rms) for 1 min between adjacent terminals and ground of mate connectors",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Current discontinuity (vibration)",+ "symbol": "",+ "kind": "electrical",+ "unit": "µsec",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "Mate connectors during vibration test (1.5 mm p-p, 10-55-10 Hz, 2 h per axis)",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Terminal crimp wire pull-out force, AWG#26",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 20,+ "typ": null,+ "max": null,+ "conditions": "Axial pull-out at 25±3 mm/min, AWG#26 wire",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Terminal crimp wire pull-out force, AWG#28",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 13,+ "typ": null,+ "max": null,+ "conditions": "Axial pull-out at 25±3 mm/min, AWG#28 wire",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Terminal crimp wire pull-out force, AWG#30",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 8,+ "typ": null,+ "max": null,+ "conditions": "Axial pull-out at 25±3 mm/min, AWG#30 wire",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Single contact withdrawal force",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 0.3,+ "typ": null,+ "max": null,+ "conditions": "Pull-out at 25±3 mm/min along wire direction",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Fixed terminals and hole seat force",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 7,+ "typ": null,+ "max": null,+ "conditions": "Pull-out at 25±3 mm/min",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Single contact insertion force",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "Mating at 25±3 mm/min",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Pin retention (seat pull-out) force",+ "symbol": "",+ "kind": "tolerance",+ "unit": "N",+ "min": 5,+ "typ": null,+ "max": null,+ "conditions": "Force on pin end at 25±3 mm/min until pin exits seat",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance after durability",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "30 cycles at max 10 cycles/min, before environmental test",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance after thermal aging",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "85±2℃, 96 hours continuously",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Temperature rise at maximum rated current",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "Maximum rated current passed through mate connector",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance after humidity test",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "40±2℃, RH 90-95%, 96 hours continuously",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Insulation resistance after humidity test",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": 100,+ "typ": null,+ "max": null,+ "conditions": "40±2℃, RH 90-95%, 96 hours continuously (as printed)",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance after temperature cycling",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "-55±3℃ 30 min and 85±3℃ 30 min, 5 cycles (requirement 'same as 8.3')",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Contact resistance after salt spray",+ "symbol": "",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "35±3℃, solution 5±1%; 48 h if stamped before tin plating, 8 h if stamped after",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Solderability (wetted area)",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": 90,+ "typ": null,+ "max": null,+ "conditions": "Solder temperature 245±5℃, immersion 3±0.5 s",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature (packaged)",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": -20,+ "typ": null,+ "max": 40,+ "conditions": "Packaged product in warehouse, no acidic/alkaline/corrosive gas",+ "source_page": 14,+ "source": "datasheet"+ },+ {+ "name": "Storage relative humidity (packaged)",+ "symbol": "",+ "kind": "thermal",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 80,+ "conditions": "Packaged product storage, -20 to +40℃",+ "source_page": 14,+ "source": "datasheet"+ },+ {+ "name": "Transport temperature",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": -20,+ "typ": null,+ "max": 50,+ "conditions": "Transport; moisture-proof, no mechanical damage",+ "source_page": 14,+ "source": "datasheet"+ },+ {+ "name": "Exposure temperature after package opened",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "Use all within 24 h after opening",+ "source_page": 13,+ "source": "datasheet"+ },+ {+ "name": "Exposure humidity after package opened",+ "symbol": "",+ "kind": "thermal",+ "unit": "%RH",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "Use all within 24 h after opening",+ "source_page": 13,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "hc-gh-13plt-05"+ ],+ "discovery_pitch": "HC-GH-13PLT-05 (HCTL) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": { "name": "Ray", "email": "[email protected]"- }-}+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "hc-gh-13plt-05.kicad_sym",+ "hc-gh-13plt-05.kicad_mod",+ "hc-gh-13plt-05.glb",+ "hc-gh-13plt-05.step",+ "hc-gh-13plt-05.lbr",+ "docs/hero.png",+ "docs/hc-gh-13plt-05-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "hc-gh-13plt-05-hero.glb",+ "hc-gh-13plt-05-hero.overlay.json"+ ]+}