main
John Lauer adom-fields 0.7.19: barrelCoupling report (PR #212), one plated connection per hole per layer pair, current-barrel issu… e4c4246

adom-fields 0.7.19

  • The summary carries barrelCoupling (model distributed-plated-wall, 25 µm plating, drill voids removed, the wall quadrature used), the reviewed plated-wall model from PR 9 (wiki PR #212) that ported in 0.7.17.
  • Every net reports exactly one platedConnections entry per via or plated pad per adjacent pair of its layers: amps, barrelAreaMm2, meanBarrelJ (= |amps| / area), resolvedPerimeterFraction (share of the wall on cells with copper on both faces), and fallback / unconnected flags when the wall resolved no copper and the nearest copper cells carried it.
  • A plated connection whose mean barrel density exceeds the --neck threshold is a current-barrel issue (medium), as in PR 9.
  • Issue 13 (bug 3): a poured switching node no longer raises no-reference from its few unreferenced edge cells; on a pour the unreferenced area itself has to pass 2 mm².