R11 v5 thermal review — gate remains open

The saved v5 PCB was re-solved with the exploratory external Q1 network at 0.2 mm pitch. This is a sensitivity study, not accepted cooling data. The 0.1 mm current-only acceptance is separate. The accepted run spec and original limits are unchanged.
| Part | Screening source W | Still-air rise C | Moving-air rise C |
|---|---|---|---|
| Q1 | 5.5000 | 49.35 | 12.73 |
| D1 | 0.5133 | 30.70 | 22.40 |
| RSH1 | 0.0300 | 13.20 | 6.20 |
Q1 uses datasheet junction-to-case 0.42 K/W, an assumed 0.7 K/W interface, assumed 8 K/W passive sink, catalog 1.2 K/W ducted-air scenario, and assumed 100 K/W per lead. These assumptions are not a verified installed assembly. Sources and manufacturer requests are in the sourcing review and data requests.
The rectifier remains PCB-cooled. Its 30.7 C still-air rise is below its 35 C budget in this scenario, but depends on removing Q1 heat through the external path. It does not justify an unconditional rectifier qualification claim.
What the budgets require
At the conservative 5.5 W Q1 screening input, a 15 C junction-rise budget permits total junction-to-ambient resistance of at most 2.73 K/W. Subtracting 0.42 K/W junction-to-case and the illustrative 0.7 K/W interface leaves 1.61 K/W for sink, localized spreading and other interface uncertainty. A catalog 1.2 K/W value leaves only 0.41 K/W; free-air fan CFM does not prove that operating point.
Firmware trips on the upper bound of case temperature, not junction temperature. At 40 C ambient, a hypothetical 3 C sensor/attachment error allowance leaves a nominal case target below 52 C. At 5.5 W this allows 2.18 K/W from case to ambient, leaving 1.48 K/W after the assumed interface. The 3 C allowance is illustrative, not a calibrated margin. The existing sensor qualification lock remains.
Fan failure is a transient problem
The assumed passive network fails the original continuous-load budget. Do not replace the fan-off case with zero heat or waive it based on RPM feedback. Eight valid tach periods and the 15 ms stale limit are checked in software; the synthetic scheduler suite bounds fault observation by 15 ms plus its polling interval, at the tested qualified speed. This does not measure physical output turn-off or heat propagation.
For example, 5.5 W maintained for 30 ms deposits 0.165 J before considering analog turn-off delay or stored energy. Converting that into temperature requires the package transient impedance, contact and sink thermal capacitance, starting temperature and actual shutdown waveform. No invented lumped capacitance or extrapolated steady-state result is accepted as a fan-stall test.
An instrumented fixture procedure is prepared. Detailed clamp and sensor retention, insulating stack, installed airflow, and fan-loss shutdown evidence are still required. The 5 W cap and 55 C case protection are retained. No manufacturing release or higher rating.
# R11 v5 thermal review — gate remains open

The saved v5 PCB was re-solved with the exploratory external Q1 network at 0.2 mm pitch. This is a sensitivity study, not accepted cooling data. The 0.1 mm current-only acceptance is separate. The accepted run spec and original limits are unchanged.
| Part | Screening source W | Still-air rise C | Moving-air rise C |
|---|---:|---:|---:|
| Q1 | 5.5000 | 49.35 | 12.73 |
| D1 | 0.5133 | 30.70 | 22.40 |
| RSH1 | 0.0300 | 13.20 | 6.20 |
Q1 uses datasheet junction-to-case 0.42 K/W, an assumed 0.7 K/W interface, assumed 8 K/W passive sink, catalog 1.2 K/W ducted-air scenario, and assumed 100 K/W per lead. These assumptions are not a verified installed assembly. Sources and manufacturer requests are in [the sourcing review](sourcing/selection.md) and [data requests](sourcing/vendor-data-requests.md).
The rectifier remains PCB-cooled. Its 30.7 C still-air rise is below its 35 C budget in this scenario, but depends on removing Q1 heat through the external path. It does not justify an unconditional rectifier qualification claim.
## What the budgets require
At the conservative 5.5 W Q1 screening input, a 15 C junction-rise budget permits total junction-to-ambient resistance of at most 2.73 K/W. Subtracting 0.42 K/W junction-to-case and the illustrative 0.7 K/W interface leaves 1.61 K/W for sink, localized spreading and other interface uncertainty. A catalog 1.2 K/W value leaves only 0.41 K/W; free-air fan CFM does not prove that operating point.
Firmware trips on the **upper bound of case temperature**, not junction temperature. At 40 C ambient, a hypothetical 3 C sensor/attachment error allowance leaves a nominal case target below 52 C. At 5.5 W this allows 2.18 K/W from case to ambient, leaving 1.48 K/W after the assumed interface. The 3 C allowance is illustrative, not a calibrated margin. The existing sensor qualification lock remains.
## Fan failure is a transient problem
The assumed passive network fails the original continuous-load budget. Do not replace the fan-off case with zero heat or waive it based on RPM feedback. Eight valid tach periods and the 15 ms stale limit are checked in software; the synthetic scheduler suite bounds fault observation by 15 ms plus its polling interval, at the tested qualified speed. This does not measure physical output turn-off or heat propagation.
For example, 5.5 W maintained for 30 ms deposits 0.165 J before considering analog turn-off delay or stored energy. Converting that into temperature requires the package transient impedance, contact and sink thermal capacitance, starting temperature and actual shutdown waveform. No invented lumped capacitance or extrapolated steady-state result is accepted as a fan-stall test.
An instrumented [fixture procedure](cooling-fixture-procedure.md) is prepared. Detailed clamp and sensor retention, insulating stack, installed airflow, and fan-loss shutdown evidence are still required. The 5 W cap and 55 C case protection are retained. No manufacturing release or higher rating.
[Exact scenario](spec-v5-package-scenario.json) · [Solver output](fields-v5-package-scenario/fields.json) · [Run log](evidence/v5-package-scenario.log)