0e57f36
R11 external Q1 heat-path exploration
This is a sensitivity scenario on the saved v2 board, not accepted thermal evidence, measured airflow, or a new power rating. The accepted run spec is unchanged. The 5 W output ceiling and original 55 C protections remain.

Why the previous board image was misleading
The board-only diagnostic injected Q1 heat into PCB terminals while omitting its proposed case-mounted sink. That cannot represent this assembly. The package network explicitly moves heat through junction, case, interface and sink, with separate weak links to the PCB. D1 remains a PCB-cooled component; it does not inherit Q1's heatsink.
Assumptions: Q1 source 5.5 W (conservative screening case), junction-case 0.42 K/W; interface 0.7 K/W, still-air sink 8 K/W and each terminal link 100 K/W are hypothetical sensitivity parameters. Moving-air sink 1.2 K/W corresponds to the ATS ducted 100 LFM catalog scenario; installed flow has not been demonstrated. This is not a simultaneous exact 5 W operating-point loss allocation.
| Part | Source W | Still-air rise C | Moving-air rise C |
|---|---|---|---|
| Q1 | 5.5000 | 49.35 | 12.73 |
| D1 | 0.5133 | 30.60 | 22.30 |
| RSH1 | 0.0300 | 13.10 | 6.20 |
At 40 C ambient the hypothetical Q1 junction is about 89.35 C still and 52.73 C moving. The still-air case fails the original 15 C Q1 rise budget. The moving case has little margin and unverified inputs, so it does not qualify the assembly. The solver's global 35 C issue label is not the tighter per-part acceptance limit.
Q1 sink/case/junction rises are 43.25/47.04/49.35 C still and 6.58/10.42/12.73 C moving. These are network nodes, not a resolved fin-temperature gradient or CFD. A three-dimensional color map must not interpolate these nodes and claim physical fin simulation.
The direct package path substantially reduces artificial PCB heating. D1's moving-air rise is 22.3 C in this scenario; that is a screen under the assumed board convection, not proof that active rectifier cooling is unnecessary in every assembly. Verify against its own component budget and the final installed arrangement.
Evidence and next work
Define exact sink/clamp/insulator geometry, localized spreading/contact, fan operating point and sensor placement. Re-solve the accepted final board, then validate fan-loss transient behavior. No thermal gate is waived here.
# R11 external Q1 heat-path exploration
This is a sensitivity scenario on the saved v2 board, not accepted thermal evidence, measured airflow, or a new power rating. The accepted run spec is unchanged. The 5 W output ceiling and original 55 C protections remain.

## Why the previous board image was misleading
The board-only diagnostic injected Q1 heat into PCB terminals while omitting its proposed case-mounted sink. That cannot represent this assembly. The package network explicitly moves heat through junction, case, interface and sink, with separate weak links to the PCB. D1 remains a PCB-cooled component; it does not inherit Q1's heatsink.
Assumptions: Q1 source 5.5 W (conservative screening case), junction-case 0.42 K/W; interface 0.7 K/W, still-air sink 8 K/W and each terminal link 100 K/W are hypothetical sensitivity parameters. Moving-air sink 1.2 K/W corresponds to the ATS ducted 100 LFM catalog scenario; installed flow has not been demonstrated. This is not a simultaneous exact 5 W operating-point loss allocation.
| Part | Source W | Still-air rise C | Moving-air rise C |
|---|---:|---:|---:|
| Q1 | 5.5000 | 49.35 | 12.73 |
| D1 | 0.5133 | 30.60 | 22.30 |
| RSH1 | 0.0300 | 13.10 | 6.20 |
At 40 C ambient the hypothetical Q1 junction is about 89.35 C still and 52.73 C moving. The still-air case fails the original 15 C Q1 rise budget. The moving case has little margin and unverified inputs, so it does not qualify the assembly. The solver's global 35 C issue label is not the tighter per-part acceptance limit.
Q1 sink/case/junction rises are 43.25/47.04/49.35 C still and 6.58/10.42/12.73 C moving. These are network nodes, not a resolved fin-temperature gradient or CFD. A three-dimensional color map must not interpolate these nodes and claim physical fin simulation.
The direct package path substantially reduces artificial PCB heating. D1's moving-air rise is 22.3 C in this scenario; that is a screen under the assumed board convection, not proof that active rectifier cooling is unnecessary in every assembly. Verify against its own component budget and the final installed arrangement.
## Evidence and next work
- [Exact scenario input](spec-package-scenario.json)
- [Solver result](fields-package-scenario/fields.json)
- [Instrumented fixture procedure](cooling-fixture-procedure.md)
Define exact sink/clamp/insulator geometry, localized spreading/contact, fan operating point and sensor placement. Re-solve the accepted final board, then validate fan-loss transient behavior. No thermal gate is waived here.