Q1 interface review — 14 October 2026
The earlier 0.7 K/W interface remains an assumption. Two documented compliant insulating pads do not support that value in their manufacturer TO-220 tests.
| Candidate | TO-220 interface at 50 psi | Junction rise at 5.5 W, assuming 1.2 K/W sink |
|---|---|---|
| Earlier assumed interface | 0.70 K/W | 12.76 C |
| Henkel TSP 1600 | 2.45 K/W | 22.39 C |
| Henkel TSP 3500, 0.010 inch | 2.02 K/W | 20.02 C |
Calculation: 5.5 × (0.42 + interface + 1.2). This is a series-path screen, not Fields simulation or measured assembly performance. It neglects parallel heat through the PCB. Manufacturer TO-220 test values depend on pressure, surface and specimen; they are not guaranteed for this Q1 clamp. The 1.2 K/W sink scenario is also unqualified for our installed airflow.
Neither pad can be accepted from this screen against the unchanged 15 C rise budget. Do not interpret area-normalized C-in²/W as C/W, or use material conductivity alone as complete joint resistance. Do not increase clamp pressure without checking Q1 and sink mechanical limits. A ceramic insulating interface with controlled thin contact layers remains a candidate, not a selected qualified part.
Sources: TSP 1600 manufacturer TDS, TSP 3500 manufacturer TDS.
Next dependency: verified sink geometry and clamp conditions, exact insulating interface, installed airflow, then complete thermal and mechanical revalidation. Supplier requests were sent with user authorization; no purchase or fabrication release.
# Q1 interface review — 14 October 2026
The earlier 0.7 K/W interface remains an assumption. Two documented compliant insulating pads do not support that value in their manufacturer TO-220 tests.
| Candidate | TO-220 interface at 50 psi | Junction rise at 5.5 W, assuming 1.2 K/W sink |
|---|---:|---:|
| Earlier assumed interface | 0.70 K/W | 12.76 C |
| Henkel TSP 1600 | 2.45 K/W | 22.39 C |
| Henkel TSP 3500, 0.010 inch | 2.02 K/W | 20.02 C |
Calculation: 5.5 × (0.42 + interface + 1.2). This is a series-path screen, not Fields simulation or measured assembly performance. It neglects parallel heat through the PCB. Manufacturer TO-220 test values depend on pressure, surface and specimen; they are not guaranteed for this Q1 clamp. The 1.2 K/W sink scenario is also unqualified for our installed airflow.
Neither pad can be accepted from this screen against the unchanged 15 C rise budget. Do not interpret area-normalized C-in²/W as C/W, or use material conductivity alone as complete joint resistance. Do not increase clamp pressure without checking Q1 and sink mechanical limits. A ceramic insulating interface with controlled thin contact layers remains a candidate, not a selected qualified part.
Sources: [TSP 1600 manufacturer TDS](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-1600-en_GL.pdf), [TSP 3500 manufacturer TDS](https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-3500-en_GL.pdf).
Next dependency: verified sink geometry and clamp conditions, exact insulating interface, installed airflow, then complete thermal and mechanical revalidation. Supplier requests were sent with user authorization; no purchase or fabrication release.