John Lauer Record current-board thermal failure without substituting PCB-only results for the cooling assembly ad296d5
ERROR: thermal analysis not passed:
D1 pass: 389 mm2 of LOAD_POS copper on B.Cu+F.Cu, about 66 C/W, 34 C at 0.51 W, 17 vias
Q1 fail: Q1: 5.50 W into 389 mm2 of LOAD_POS copper is about 365 C above ambient (budget 15 C): widen the pour or add the other outer layer with vias
RSH1 pass: 39 mm2 of SHUNT_P copper on B.Cu+F.Cu, about 655 C/W, 20 C at 0.03 W, 7 vias
(field screen: Fields D1 riseC plus 0.05 C reporting allowance exceeds its 35 C rise budget)
Hint: Fix what the failing lines say (pours, vias, widths, or placement), land it, measure again, then analyze again.
Hint: Now do the analysis yourself, not only this table, as two drawings: first the heat flow in the copper, layer by layer like the current picture (a multi-layer solve: each hot tab's watts spreading on its layer and going down through its vias to the other layers, watts per millimetre of width, with the vias drawn and each chip's split between its layer, its vias and the bare dielectric); then the temperature rise over the whole board (the same solve read as temperature, the FR4 spreading). Each a 1920x1080 PNG with a colour scale, registered in that order with `artifact --kind analysis-image --file <png> --caption "..."` (`--replaces <old png>` when you redo one). They become fullscreen shots in the final video and figures on the run page.
Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).
Hint: Input of `analyze thermal` (skill aiflow-power-layout): read /home/adom/.claude/skills/aiflow-power-layout/SKILL.md or /home/adom/project/adom_modules/adom/adom-aiflow/skills/aiflow-power-layout/SKILL.md, section "Input schemas"; also /home/adom/project/adom_modules/adom/adom-aiflow/docs/plan-schema.md.