← Commit history
Record current-board thermal failure without substituting PCB-only results for the cooling assembly
2 files changed
+14
docs/issue-repairs-20261028/README.md+5@@ -58,3 +58,8 @@ The wiring linter now also rejects duplicate physical IDs across different harne ::adom-video{src="/adom/adom-custom-electronic-load/render/docs/issue-repairs-20261028/copper-review-video/review.video.json"} [Watch/download the 26-second copper and access review](copper-review-video/review.mp4). Retrospective wiki walkthrough, captured and encoded on arav-rog; Adom TTS narration, separate captions, no burned text. Shows the failed candidate honestly. It is not original CAD-edit footage and is pending review for the final film.+++## Board-22 thermal gate readback++[AIFlow thermal output](../../revisions/compact-r11/issue-1-copper/thermal-board22.txt) remains failed on the current board. The copper heuristic passes D1 and RSH1 but fails Q1; the same-input PCB-only Fields screen also exceeds the D1 rise budget. Because this solve omits the external Q1 package/heatsink path, its hot-board values do not establish actual assembled temperatures. The earlier supplier-informed package study separately fails Q1’s unchanged 15°C rise limit. A complete cooling model and acceptable physical design are still required. Current-path issue #1 is closed; whole-board acceptance is not.
revisions/compact-r11/issue-1-copper/thermal-board22.txtadded+9@@ -0,0 +1,9 @@+ERROR: thermal analysis not passed:+D1 pass: 389 mm2 of LOAD_POS copper on B.Cu+F.Cu, about 66 C/W, 34 C at 0.51 W, 17 vias+Q1 fail: Q1: 5.50 W into 389 mm2 of LOAD_POS copper is about 365 C above ambient (budget 15 C): widen the pour or add the other outer layer with vias+RSH1 pass: 39 mm2 of SHUNT_P copper on B.Cu+F.Cu, about 655 C/W, 20 C at 0.03 W, 7 vias+(field screen: Fields D1 riseC plus 0.05 C reporting allowance exceeds its 35 C rise budget)+Hint: Fix what the failing lines say (pours, vias, widths, or placement), land it, measure again, then analyze again.+Hint: Now do the analysis yourself, not only this table, as two drawings: first the heat flow in the copper, layer by layer like the current picture (a multi-layer solve: each hot tab's watts spreading on its layer and going down through its vias to the other layers, watts per millimetre of width, with the vias drawn and each chip's split between its layer, its vias and the bare dielectric); then the temperature rise over the whole board (the same solve read as temperature, the FR4 spreading). Each a 1920x1080 PNG with a colour scale, registered in that order with `artifact --kind analysis-image --file <png> --caption "..."` (`--replaces <old png>` when you redo one). They become fullscreen shots in the final video and figures on the run page.+Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).+Hint: Input of `analyze thermal` (skill aiflow-power-layout): read /home/adom/.claude/skills/aiflow-power-layout/SKILL.md or /home/adom/project/adom_modules/adom/adom-aiflow/skills/aiflow-power-layout/SKILL.md, section "Input schemas"; also /home/adom/project/adom_modules/adom/adom-aiflow/docs/plan-schema.md.