main
John Lauer Publish input-bound R11 prototype bundle and completed CLI clearance review 7007e93

Compact R11 prototype specification

Revision: compact-sidefan-v5-native, with assumed retained side-fan cooling assembly. Status: design and fit study; not an industrial or manufacturing release. No physical rating is established. Firmware output remains locked.

Item Prototype design value / limitation
Function Digitally commanded constant-current dissipative electronic load
Power command cap 5 W; not a measured continuous rating
Current ceiling min(3 A, 5 W / input voltage), subject to compliance and qualification
Intended initial DUT 5 V, 1 A buck output
Voltage measurement target 0–24 V; does not imply loading at zero volts
Loading target 5–24 V for the selected Q1; lower-voltage compliance unverified
Auxiliary supply Separate control-panel5V supply; USB data-only; non-isolated
Protection targets 55°C case trip; tach-loss fault; original40°C ambient and15°C Q1 rise screen retained
Q1 IXTP15N50L2, direct case-to-sink path through assumed AlN interface
Rectifier SBR10U45SP5-13
Heatsink ATS-FPX040040035-66-C2-R0;40×40×35mm fin body; detailed model assumed
Fan Same Sky CFM-4010-03-22;40×40×10.6mm, tach/PWM; installed airflow unmeasured
PWM 25kHz bench-only implementation assumption; exact fan contract and hardware response unverified
PCB 72×72mm; two layers;1oz finished copper;3rdPartyFab
Scaffold interface Four large pins on64×64mm centers
Cooling/carrier envelope 83.75×76.25×56.4mm; downward machine pins add to installed height
Nominal fit checks Input-bound board-solid and internal-contact reviews provided; no tolerance/strength qualification
Test access 18 distinct board measurements; full retained-assembly fixture replay reported separately
Control USB/UART integration is prototype software; compiled hardware image is output-locked

The thermal series-network sweep is a sensitivity estimate, not resolved 3D heat flow or physical qualification. Fan-off cases fail the unchanged temperature-rise budget. Do not infer a higher load rating from fan catalogue airflow, a heatsink catalogue resistance or a clean geometry check.

Files: assembly, interface and thermal sweep, mechanical BOM, costs, fabrication review, and physical test procedure.