main
John Lauer Select explicit prototype cooling model and preserve pending assembly qualification b777c73
{
  "status": "proposed-machining-not-release",
  "sourceSha256": "f2e18b418d8b68f387ffab20c705df404bd3b7bf88b8705656a2d5130efb838b",
  "pilotDiameterMm": 2.5,
  "pilotXYmm": [
    127.46,
    65.34
  ],
  "cylindricalDepthMm": 7.5,
  "drillPointIncludedMm": 0.7510757737844503,
  "pilotMaximumZmm": 15.50107577378445,
  "baseTopZmm": 14.362,
  "extendsIntoFinRootMm": 1.13907577378445,
  "fullThreadDepthTargetMm": 6.5,
  "screwEngagementNominalMm": 5.935,
  "removedVolumeMm3": 35.005963984353,
  "validSingleSolid": true,
  "limitations": [
    "This explicitly removes material beyond the7.112mm base into a local fin root. Stock heatsink is not predrilled.",
    "A bottoming-tap process must achieve the stated full-thread depth; supplier DFM and tap lead clearance remain to verify.",
    "Thread helices, tolerances, burrs, machining access fixtures, preload and PEEK creep are not qualified.",
    "Published thermal resistance is retained only as a design assumption; machining and installed obstruction require later measurement.",
    "Manufacturer CAD derivative remains local; public asset is an original context model."
  ]
}