main
John Lauer Document same-input current comparison and correct current MOSFET candidate 80cf331

Thermal copper checkpoint — 2026-10-08

Four local solid-connected zones were added on both copper faces around D1 (LOAD_POS) and the positive shunt terminal (SHUNT_P). Three 0.8 mm / 0.4 mm vias at (110,93), (111.2,93), and (112.4,93) connect the diode regions. The actual saved replay has 1,675 segments and 257 vias, matches the accepted candidate track/via geometry, and has zero native DRC findings and open connections under the recorded checks.

The initial dense via array collided with routed signals. After pruning it, one proposed shunt via at (135.2,87.2) disconnected a ground region; it was rejected. Only the three diode vias were landed. Existing power vias remain. This is not fulfillment of an arbitrary thermal-via count and does not qualify the external MOSFET cooling assembly.

The zone-area comparison is native filled-polygon area, not total copper union or measured thermal improvement. Ground-area loss and isolated region connectivity were checked through refill and native DRC. Full current/thermal acceptance remains pending. The 5 W bring-up ceiling and unresolved 25 W design target remain unchanged.

Evidence: saved DRC, saved geometry audit, fill comparison, and recorded additions.

The same 3 A, 0.2 mm explicit-terminal electrical screen converged on all five power paths. LOAD_POS peak density decreases from 89.7 to 83.0 A/mm² and SHUNT_P from 96.2 to 92.3 A/mm². Summed modeled conductor loss decreases from 0.213 to 0.206 W; GND loss increases from 0.027 to 0.028 W as power regions replace ground area. Four neck flags remain. These are mesh-dependent screening values, not operating ratings. Comparison.