main
John Lauer Document cooling envelope tradeoff and verify published shutdown replay 65bd320

Measured cooling and fan-fault capture

No assembled-unit measurement is present. The STM32 bring-up image remains output locked. This procedure prepares evidence collection for a later reviewed bench build; it does not authorize flashing, enabling an unqualified assembly, or manufacturing release.

Use an independent case-temperature reference at the defined Q1 case location, an ambient reference, and a current measurement with sufficient bandwidth to observe shutdown. Record enable, tachometer and fault-injection timing on a common timebase. Keep the sensor location, attachment, instrument identities, calibration dates, uncertainty calculations and acquisition settings with the trace. Case temperature inferred only from the existing NTC is insufficient to qualify that NTC's attachment and lag.

Identify the exact PCB, firmware binary, MOSFET, isolator, grease application, clamp, sink, fan, duct and sensor mounting. Photograph the assembly and record its serial identifier. Establish the approved operating condition and stopping criteria before applying load. The unchanged design limits are 40 °C assumed ambient and 55 °C actual case ceiling; instrument under-reading and lag consume the available margin. The 5.5 W Q1 heat allowance is a guard condition, not a new 5.5 W customer setting.

Collect separate traces for fan loss, obstructed airflow with continuing tach pulses, tach open/short/noise, sensor open/short, communications loss, and power/reset transitions. Use the reviewed acquisition plan to define each fault's deadline, observation duration, current-off criterion and sample-gap limit. Do not infer a hardware deadline from the host scheduler test: it excludes actual MCU scheduling, I2C latency and analog current decay. Retain the temperature transient after shutdown until the acquisition plan's observation condition is met.

tools/check_thermal_capture.py reviews the recorded samples. Its CSV columns are:

time_s,case_c,ambient_c,current_a,load_enabled,fan_rpm

Copy qualification/thermal-capture.template.json for each trace. Fill the missing entries from the actual setup and reviewed plan; file paths resolve relative to the manifest. Run:

python3 tools/check_thermal_capture.py qualification/your-capture.json --out qualification/your-review.json

The checker rejects missing evidence, non-finite samples, backwards time, excessive sample gaps, absent pre-fault load, excessive case temperature including stated uncertainty, residual current, late shutdown and later restart. It uses both enable deassertion and measured current decay. The timing bound includes uncertainty on both timestamps. It hashes the inputs and evidence files. Synthetic traces cannot become eligible hardware evidence.

A sample-check-pass covers only the supplied sampled trace and asserted uncertainty. It cannot independently verify calibration documents, test severity, instrument bandwidth, sensor placement, between-sample peaks or a complete qualification matrix. Ambient and RPM are retained observations, not proof of the specified ambient or installed airflow. A reviewer must establish those conditions and adequate measurement coverage separately. The checker does not update AIFlow gates, change firmware qualification, or approve the assembly.

The checked-in readiness report intentionally says blocked because no hardware capture or acquisition uncertainty is available. Thirteen unit tests exercise the checker using temporary synthetic data; those tests are software evidence only.

For the new qualified-temperature guard, retain paired nominal device estimates alongside the independent reference trace on a justified common timebase. The CSV case_c above is the independent reference case measurement, not the device's uncalibrated estimate. Preserve device estimates as a separate channel; this checker does not derive a production case_margin_c. A reviewed margin must cover the observed under-reading, reference uncertainty, channel alignment, attachment gradients and unobserved/transient behavior across the qualification matrix. The synthetic 2 °C test allowance must never be copied into assembly calibration.