0a4a228
Reconcile v85 pour evidence
Adopting v85 correctly invalidated earlier landing outcomes. Its filled copper was subsequently measured, but the stored landing plan still described the smaller D1 spreaders. Replaying that plan would undo reviewed current-density improvements.
The reconciled plan changes only the front and back D1 polygons from the historical aiflow/run/plan-pours.json. These coordinates come from the explicit native construction in tools/hotspot_via_candidate_v84.py line 184, retained by v85's duplicate-track removal. The other seven entries, including both Kelvin keepouts and the Q1-source spreader, remain unchanged.
The front polygon spans the reviewed stepped region from x104–132 mm, y82–99 mm. The back polygon reaches y70 mm and uses the reviewed stepped boundary around existing components. Exact vertices remain in the JSON. This is an intended-plan reconciliation, not permission to infer ownership or replace zones.
Read-only AIFlow verification compares every planned zone with the saved board, including settings, layers, nets and fills. Its native DRC, live measurement and current/thermal analyses remain separate evidence. The original analysis spec and its input-bound current result are preserved; this reviewed explicit landing plan does not claim the old descriptive spec.pours polygons are synchronized.
AIFlow 0.1.86 rejected the historical D1 plan and accepted all nine entries of the reconciled plan. The active run now records verified-existing, retaining all nine prior owned zone IDs. The PCB SHA-256 remains unchanged. The finish guard now identifies thermal as the earliest incomplete step; failed thermal and historical via evidence remain visible.
# Reconcile v85 pour evidence
Adopting v85 correctly invalidated earlier landing outcomes. Its filled copper was subsequently measured, but the stored landing plan still described the smaller D1 spreaders. Replaying that plan would undo reviewed current-density improvements.
[The reconciled plan](../design/pour-plan-v85.json) changes only the front and back D1 polygons from the historical `aiflow/run/plan-pours.json`. These coordinates come from the explicit native construction in `tools/hotspot_via_candidate_v84.py` line 184, retained by v85's duplicate-track removal. The other seven entries, including both Kelvin keepouts and the Q1-source spreader, remain unchanged.
The front polygon spans the reviewed stepped region from x104–132 mm, y82–99 mm. The back polygon reaches y70 mm and uses the reviewed stepped boundary around existing components. Exact vertices remain in the JSON. This is an intended-plan reconciliation, not permission to infer ownership or replace zones.
Read-only AIFlow verification compares every planned zone with the saved board, including settings, layers, nets and fills. Its native DRC, live measurement and current/thermal analyses remain separate evidence. The original analysis spec and its input-bound current result are preserved; this reviewed explicit landing plan does not claim the old descriptive `spec.pours` polygons are synchronized.
AIFlow 0.1.86 rejected the historical D1 plan and accepted all nine entries of the reconciled plan. The active run now records `verified-existing`, retaining all nine prior owned zone IDs. The PCB SHA-256 remains unchanged. The finish guard now identifies thermal as the earliest incomplete step; failed thermal and historical via evidence remain visible.