main
John Lauer Record progress to current step 12, converged main-path diagnostic and unresolved formal gates 526eaf9

KiCad Bridge 1.0.55; Adom Bridge 2.1.173 (a4e626c9-dirty); AIFlow 0.1.77; native KiCad 10.0.5 on Windows. Observed 2026-10-09.

Repeated kicad_apply_zone_plan is not idempotent for the two-layer copper-pour keepouts in the electronic-load run. First call creates two rule areas. After native refill/save/readback, submit the identical plan with the returned ownedItemIds and fresh expectedRevision. Expected: all nine zone IDs unchanged, no mutation. Actual: seven copper zones unchanged, but both keepouts removed and recreated with new UUIDs; success=true, committed=true, mutated=true. No error message; DRC errors=0, unconnected=0, warnings=15 inherited library lookup warnings.

Full canonical native zone definitions before/after are identical ignoring UUIDs, and filled areas are identical (F.Cu 2684.25 mm2, B.Cu 2653.06 mm2). Evidence and exact IDs are at https://wiki.adom.inc/adom/adom-custom-electronic-load/files/design/step10-repeat-review.json and the accompanying step10-repeat-land-pours.json. We stopped replaying rather than creating an endless adopt/invalidate/reland cycle.

Likely cause to verify against current source: generated keepout S-expression omits defaults that KiCad serializes (connect_pads clearance 0, min_thickness 0.25, disabled placement and island_removal_mode 0). Existing canonicalization handles some copper defaults but may not normalize rule-area defaults. Please add a native serialized keepout regression, preserve unknown properties and nondefault flags, and verify a second live call returns unchanged IDs and mutated=false. This report is not a source fix or deployed release.