8e53907
Harness fabrication and service review
Status: design in progress; do not build from this table alone. The fan connector is being moved nearer the lead exit. The PH sensor assembly is being corrected for curve overshoot, neighboring connector access and sensor screw access.
| Harness | Required item | Quantity | Component page / status |
|---|---|---|---|
| Fan J9 | JST BM04B-GHS-TBT PCB header | 1 | Header, source verified 16 Oct |
| Fan J9 | JST GHR-04V-S cable housing | 1 | Housing, source verified 16 Oct |
| Fan J9 | JST SSHL-002T-P0.2 contacts | 4 | Crimp contact, source verified 16 Oct |
| Fan J9 | Factory leads on CFM-4010-03-22 | 4 supplied with fan | Fan; no additional extension wire selected. Exact insulation diameter must be verified against contact range before termination. |
| Sensor J10 | JST B2B-PH-K-S PCB header | 1 | Header |
| Sensor J10 | JST PHR-2 housing | 1 | Housing; source exists, native assets and mating qualification remain incomplete |
| Sensor J10 | JST SPH-002T-P0.5S contacts | 2 | Crimp contact; source exists, crimp qualification remains incomplete |
| Sensor J10 | Factory leads on NTCALUG01T103GA | 2 supplied with sensor | Dedicated exact long-lead sensor page and lead documentation still required; do not substitute the short G400A variant |
| Both | Exact approved crimp tools/dies, strip tools and release tooling | As specified | Selection and supplier verification pending; generic pliers are not an approved substitution |
Electrical map
| Harness | Board pin | Signal | Factory wire color |
|---|---|---|---|
| Fan | J9.1 | 5V_AUX | Red |
| Fan | J9.2 | GND | Black |
| Fan | J9.3 | FAN_TACH | Yellow |
| Fan | J9.4 | FAN_PWM | Blue |
| Sensor | J10.1 | TEMP_SENSE | Blue; mark this conductor at both ends |
| Sensor | J10.2 | GND | Blue; mark this conductor at both ends |
This is the project electrical mapping. Assembly drawings must still establish mating-face versus wire-entry-face numbering using the exact housing; do not infer left-to-right order from this table. Confirm factory colors against the exact delivered part.
Build sequence to complete before fabrication release
- Verify exact fan/sensor part, wire gauge and insulation diameter; select contacts covering the full tolerance range.
- Freeze connector location and housing insertion direction, reserve latch/tool and withdrawal space, then freeze retained wire lengths including service slack and strip allowances.
- Specify supplier-approved tool/die and setup, strip length, conductor and insulation crimp inspection criteria. These numeric settings are not yet verified and must not be guessed.
- Crimp sample contacts; inspect and qualify pull strength. Insert terminals into the exact housing with correct orientation and verify retention.
- Verify end-to-end continuity, polarity and absence of shorts with the harness disconnected and power off.
- Install the harness in its intended clips, checking bend radius, no abrasion, no fan contact, no blocked plugs and no load on the crimp barrels.
- Verify latch release and withdrawal using the required tool, supporting the PCB. Measure or obtain specified mating/unmating force; do not pull on wires.
Installed geometry must contain exactly four fan conductors and two sensor conductors, with one continuous path each. Remove replaced factory stubs. Curves must enter the actual wire-entry cavities with straight lead-out and verified bend radii. Check full insulation envelopes and all neighboring connector service paths.
Tool and mating animations are optional review aids. They do not establish crimp quality, extraction force or physical fit.
Manufacturer tooling research, 16 October
JST's tooling matrix and regional product pages identify WC-GH2630 for GH SSHL-002 contacts and WC-240 for PH SPH-002 contacts. GH's tool is a mini-reel hand tool; a bag of individually cut terminals is not automatically the right consumable. Confirm the exact reel/contact supply form with the tool instructions before ordering. The matrix also lists EJ-PH for PH extraction; verify its actual removal procedure and accessible working envelope before selecting it for service.
These are manufacturer-listed tool candidates, not a qualified crimp process on our actual wires. Strip length, crimp dimensions, pull force, insulation OD and setup still require exact instruction sheets and sample validation. No crimp-tool ownership or availability is assumed.
28 October review inventory correction
The required wiring review now inventories both J9 and J10. Native board-19 pin maps match the table above. The cached Vishay 28-Apr-2026 datasheet confirms AWG26, insulation OD 0.93 ±0.10 mm and 150 ±10 mm supplied leads for NTCALUG01T103GA; the review therefore records 140 mm minimum available lead length. This does not establish the final cut length, wire color, crimp setup or service clearance. Those verification flags remain unresolved. The exact long-lead sensor wiki page was not found in the live registry.
# Harness fabrication and service review
Status: design in progress; do not build from this table alone. The fan connector is being moved nearer the lead exit. The PH sensor assembly is being corrected for curve overshoot, neighboring connector access and sensor screw access.
| Harness | Required item | Quantity | Component page / status |
|---|---|---:|---|
| Fan J9 | JST BM04B-GHS-TBT PCB header | 1 | [Header](https://wiki.adom.inc/adom/bm04b-ghs-tbt), source verified 16 Oct |
| Fan J9 | JST GHR-04V-S cable housing | 1 | [Housing](https://wiki.adom.inc/adom/ghr-04v-s), source verified 16 Oct |
| Fan J9 | JST SSHL-002T-P0.2 contacts | 4 | [Crimp contact](https://wiki.adom.inc/adom/sshl-002t-p0-2), source verified 16 Oct |
| Fan J9 | Factory leads on CFM-4010-03-22 | 4 supplied with fan | [Fan](https://wiki.adom.inc/adom/cfm-4010-03-22); no additional extension wire selected. Exact insulation diameter must be verified against contact range before termination. |
| Sensor J10 | JST B2B-PH-K-S PCB header | 1 | [Header](https://wiki.adom.inc/adom/b2b-ph-k-s) |
| Sensor J10 | JST PHR-2 housing | 1 | [Housing](https://wiki.adom.inc/adom/phr-2); source exists, native assets and mating qualification remain incomplete |
| Sensor J10 | JST SPH-002T-P0.5S contacts | 2 | [Crimp contact](https://wiki.adom.inc/adom/sph-002t-p0-5s); source exists, crimp qualification remains incomplete |
| Sensor J10 | Factory leads on NTCALUG01T103GA | 2 supplied with sensor | Dedicated exact long-lead sensor page and lead documentation still required; do not substitute the short G400A variant |
| Both | Exact approved crimp tools/dies, strip tools and release tooling | As specified | Selection and supplier verification pending; generic pliers are not an approved substitution |
## Electrical map
| Harness | Board pin | Signal | Factory wire color |
|---|---:|---|---|
| Fan | J9.1 | 5V_AUX | Red |
| Fan | J9.2 | GND | Black |
| Fan | J9.3 | FAN_TACH | Yellow |
| Fan | J9.4 | FAN_PWM | Blue |
| Sensor | J10.1 | TEMP_SENSE | Blue; mark this conductor at both ends |
| Sensor | J10.2 | GND | Blue; mark this conductor at both ends |
This is the project electrical mapping. Assembly drawings must still establish mating-face versus wire-entry-face numbering using the exact housing; do not infer left-to-right order from this table. Confirm factory colors against the exact delivered part.
## Build sequence to complete before fabrication release
1. Verify exact fan/sensor part, wire gauge and insulation diameter; select contacts covering the full tolerance range.
2. Freeze connector location and housing insertion direction, reserve latch/tool and withdrawal space, then freeze retained wire lengths including service slack and strip allowances.
3. Specify supplier-approved tool/die and setup, strip length, conductor and insulation crimp inspection criteria. These numeric settings are not yet verified and must not be guessed.
4. Crimp sample contacts; inspect and qualify pull strength. Insert terminals into the exact housing with correct orientation and verify retention.
5. Verify end-to-end continuity, polarity and absence of shorts with the harness disconnected and power off.
6. Install the harness in its intended clips, checking bend radius, no abrasion, no fan contact, no blocked plugs and no load on the crimp barrels.
7. Verify latch release and withdrawal using the required tool, supporting the PCB. Measure or obtain specified mating/unmating force; do not pull on wires.
Installed geometry must contain exactly four fan conductors and two sensor conductors, with one continuous path each. Remove replaced factory stubs. Curves must enter the actual wire-entry cavities with straight lead-out and verified bend radii. Check full insulation envelopes and all neighboring connector service paths.
Tool and mating animations are optional review aids. They do not establish crimp quality, extraction force or physical fit.
## Manufacturer tooling research, 16 October
JST's [tooling matrix](https://www.jst-mfg.com/product/pdf/eng/eCRIMPING_MACHINES_AND_TOOLS.pdf) and regional product pages identify [WC-GH2630](https://www.jst.co.uk/productSeries.php?cat=71&pid=10728) for GH SSHL-002 contacts and [WC-240](https://www.jst.co.uk/productSeries.php?pid=10689) for PH SPH-002 contacts. GH's tool is a **mini-reel** hand tool; a bag of individually cut terminals is not automatically the right consumable. Confirm the exact reel/contact supply form with the tool instructions before ordering. The matrix also lists EJ-PH for PH extraction; verify its actual removal procedure and accessible working envelope before selecting it for service.
These are manufacturer-listed tool candidates, not a qualified crimp process on our actual wires. Strip length, crimp dimensions, pull force, insulation OD and setup still require exact instruction sheets and sample validation. No crimp-tool ownership or availability is assumed.
## 28 October review inventory correction
The required wiring review now inventories both J9 and J10. Native board-19 pin maps match the table above. The cached Vishay 28-Apr-2026 datasheet confirms AWG26, insulation OD 0.93 ±0.10 mm and 150 ±10 mm supplied leads for NTCALUG01T103GA; the review therefore records 140 mm minimum available lead length. This does not establish the final cut length, wire color, crimp setup or service clearance. Those verification flags remain unresolved. The exact long-lead sensor wiki page was not found in the live registry.