main
John Lauer Document measured copper improvements and stricter full pin-handling replay 2c71e6b

Copper and probing review, 16 October

Design review only; not a fabrication release. R4 retains the two-layer,1oz stackup, all component positions from the fan-clearance candidate, and the5W bring-up cap. Native refill/DRC reports zero violations and zero opens.

Current-density comparison

Both runs use0.1mm cells and the same load budgets and60A/mm² threshold. The5V_AUX result remains a conservative inferred-terminal screen; explicit branch budgeting is a separate review.

Net Earlier trial A/mm² R4 A/mm² R4 result
DUT_POS 172.44 67.35 Fail
LOAD_POS 47.59 47.59 Pass
DUT_FUSED 133.66 96.70 Fail
SHUNT_P 58.75 58.75 Pass
GND 119.37 58.54 Pass
5V_AUX 75.62 59.33 Pass

The input bend and fused-supply common branch still fail. R5 widens those specific constrictions; native DRC is clean and its fresh Fields solve is pending. Do not infer a current pass from trace width or native DRC. Near-threshold results also need a mesh-resolution sensitivity check.

The board-only thermal screen still fails and omits Q1’s external cooler path. Its high temperatures must not be presented as assembled-cooler predictions. Coupled package/interface/heatsink analysis and the existing thermal limits remain open.

Stricter nominal probing

R4 passes all six input-bound stages with the handling/jaw extension:19,175 head poses,940 cable solves,zero collisions,snags,unreachable poses or jaw contacts. Ground uses medium J7,not a large scaffold pin. Cable sampling includes held,inserting,releasing,clearing,descending,gripping,lifting and seated states at0.25s intervals. This is quasi-static sampled planning,not continuous swept-volume or physical qualification.

Shared source fix:dc0dc2d919f29b6ba53145adfd4f57e978a98e39;18 unit tests pass. The task-local release is built. Registry and installed Windows runtimes are separate and not updated. Browser obstacle parity remains unresolved,so no successful browser replay is claimed.

Video

Watch the latest narrated fan-connector comparison. Recorded/rendered on arav-rog; separate captions,no burned text,and no raw media on AdomLapper. It shows the connector moving3mm toward the fan and the shorter four-wire harness.

Evidence