da85333
Board model review — board24 prototype
The current review GLB uses AIFlow board24, including the two-sided contact labels. AIFlow 0.1.88 passes the copper/mask and opaque physical-silkscreen checks: 295 exposed pads and 40 bare contacts/test points. The nominal cooling assembly retains one Fan.Rotor and its Fan.Rotor.Revolution animation. Cooling retention, installed airflow and qualification remain open.
Board GLB · Nominal assembly GLB · Fan state metadata · Material/mask check · Native two-sided review clip
The bare top and nominal assembly were inspected in the canonical viewer. Native top, bottom and oblique views were recorded. This is prototype geometry, not a fabrication release. The sink remains a clearance envelope and mounting details remain provisional. Historical v85 exports and validation are retained separately; they are not relabeled as board24 evidence.
Native save reorders artwork and rounds it to KiCad's 1 nm coordinate precision. Post-measure comparison proves numerically identical circuit, copper and fills, and bounds artwork serialization changes. The original analysis snapshot and native saved file are both retained.
Electrical interface
All eleven interface pad identities agree between the saved PCB and the independent netlist. Their converter coordinates also agree relative to MP1. Names include reference designators so multiple ground contacts remain individually addressable.
| Reference | Electrical net | Unique connection name |
|---|---|---|
| J1 | DUT_POS | DUT_POS_J1 |
| J2 | GND | GND_J2 |
| J3 | 5V_AUX | 5V_AUX_J3 |
| J4 | GND | GND_J4 |
| J5 | UART_TX | UART_TX_J5 |
| J6 | UART_RX | UART_RX_J6 |
| J7 | GND | GND_J7 |
| MP1–MP4 | GND | GND_MP1 through GND_MP4 |
UART names are from the load's perspective: TX is its output and RX is its input. Auxiliary power is separate from the DUT. These labels do not establish connector current ratings or electrical qualification.
Checked map and limitations · Named footprint derivative · Named symbol derivative · Reproduce the interface audit
The converter's raw outputs are preserved. They use duplicate generic contact names and a simplified symbol representation. Registration/widget compatibility is not validated. The anchoring report also identifies the medium size as an explicit parameter rather than marker-derived. These contract gaps are tracked in adom/adom-step2glb#25; they are not silently waived for final molecule publication.
# Board model review — board24 prototype
The current review GLB uses AIFlow board24, including the two-sided contact labels. AIFlow 0.1.88 passes the copper/mask and opaque physical-silkscreen checks: 295 exposed pads and 40 bare contacts/test points. The nominal cooling assembly retains one `Fan.Rotor` and its `Fan.Rotor.Revolution` animation. Cooling retention, installed airflow and qualification remain open.
[Board GLB](../mechanical/board24-review/board24.glb) · [Nominal assembly GLB](../mechanical/board24-review/assembly-board24-study.glb) · [Fan state metadata](../mechanical/board24-review/assembly-states.json) · [Material/mask check](../mechanical/board24-review/copper-mask-check.json) · [Native two-sided review clip](clips/two-sided-contacts-native.mp4)
The bare top and nominal assembly were inspected in the canonical viewer. Native top, bottom and oblique views were recorded. This is prototype geometry, not a fabrication release. The sink remains a clearance envelope and mounting details remain provisional. Historical v85 exports and validation are retained separately; they are not relabeled as board24 evidence.
Native save reorders artwork and rounds it to KiCad's 1 nm coordinate precision. [Post-measure comparison](../design/silkscreen-review/front-contacts/postmeasure-equivalence.json) proves numerically identical circuit, copper and fills, and bounds artwork serialization changes. The original analysis snapshot and native saved file are both retained.
## Electrical interface
All eleven interface pad identities agree between the saved PCB and the independent netlist. Their converter coordinates also agree relative to MP1. Names include reference designators so multiple ground contacts remain individually addressable.
| Reference | Electrical net | Unique connection name |
|---|---|---|
| J1 | DUT_POS | DUT_POS_J1 |
| J2 | GND | GND_J2 |
| J3 | 5V_AUX | 5V_AUX_J3 |
| J4 | GND | GND_J4 |
| J5 | UART_TX | UART_TX_J5 |
| J6 | UART_RX | UART_RX_J6 |
| J7 | GND | GND_J7 |
| MP1–MP4 | GND | GND_MP1 through GND_MP4 |
UART names are from the load's perspective: TX is its output and RX is its input. Auxiliary power is separate from the DUT. These labels do not establish connector current ratings or electrical qualification.
[Checked map and limitations](../mechanical/board24-review/interface-check.json) · [Named footprint derivative](../mechanical/board24-review/board24-named_footprint.json) · [Named symbol derivative](../mechanical/board24-review/board24-named_symbol.json) · [Reproduce the interface audit](../tools/molecule_interface_board24.py)
The converter's raw outputs are preserved. They use duplicate generic contact names and a simplified symbol representation. Registration/widget compatibility is not validated. The anchoring report also identifies the medium size as an explicit parameter rather than marker-derived. These contract gaps are tracked in [adom/adom-step2glb#25](https://wiki.adom.inc/adom/adom-step2glb/issues/25); they are not silently waived for final molecule publication.