main
John Lauer Record progress to current step 12, converged main-path diagnostic and unresolved formal gates 526eaf9
ERROR: current analysis not passed:
5V_AUX pass: the narrowest listed track carries the full specified load within 10 C
DUT_FUSED fail: DUT_FUSED carries 3.0 A on a 1.00 mm bottleneck (17 C rise, limit 10 C) and has no pour: pour it on the outer layers or widen to 1.5 mm
DUT_POS fail: DUT_POS carries 3.0 A on a 0.25 mm bottleneck (164 C rise, limit 10 C) and has no pour: pour it on the outer layers or widen to 1.5 mm
GND pass: pour on B.Cu+F.Cu (5201 mm2 filled) carries the load; tracks are 0.25 mm at most
LOAD_POS pass: pour on B.Cu+F.Cu (98 mm2 filled) carries the load; tracks are 1.50 mm at most
SHUNT_P pass: pour on B.Cu+F.Cu (38 mm2 filled) carries the load; tracks are 2.00 mm at most
(field screen: no field solve at aiflow/run/fields/fields.json; run adom-fields analyze --board aiflow/run/board-19.kicad_pcb --spec /home/adom/project/adom-custom-electronic-load/design/spec.json --out aiflow/run/fields, then analyze current --fields aiflow/run/fields/fields.json)
Hint: Fix what the failing lines say (pours, vias, widths, or placement), land it, measure again, then analyze again.
Hint: Now do the analysis yourself, not only this table: draw the current density on the copper (amps per square millimetre on every loaded net's pours and tracks; a Laplace solve on the filled copper between the source pads and the sink pads is enough, the board file has the filled polygons) as a 1920x1080 PNG with a colour scale, then `artifact --kind analysis-image --file <png> --caption "..."`. It becomes a fullscreen shot in the final video and a figure on the run page.
Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets GND,LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).