main
John Lauer Review off-board sensor and mechanical libraries with truthful conversion and supplier limits 4c1d6f7

Unadopted NTCLE428 conversion candidate

This standalone function interpolates log resistance between the 30 nominal manufacturer table nodes, -40 through 105 C. It rejects nonfinite, null-output and out-of-table inputs without replacing the caller output. It is not linked into the firmware and cannot enable the load.

Matching table nodes verifies transcription and implementation only. Interpolation error between nodes is not specified by the manufacturer. Resistance tolerance, pull-up error, ADC error, attachment gradients, self-heating and installed thermal lag still require an error budget and physical qualification. Never clamp an out-of-range reading to make it appear valid.