main
Name Last commit message Last updated
checks.json Review off-board sensor and mechanical libraries with truthful conversion and supplier limits · John Lauer
legacy-screen.json Review off-board sensor and mechanical libraries with truthful conversion and supplier limits · John Lauer
ntcle428_candidate.c Review off-board sensor and mechanical libraries with truthful conversion and supplier limits · John Lauer
README.md Review off-board sensor and mechanical libraries with truthful conversion and supplier limits · John Lauer

Unadopted NTCLE428 conversion candidate

This standalone function interpolates log resistance between the 30 nominal manufacturer table nodes, -40 through 105 C. It rejects nonfinite, null-output and out-of-table inputs without replacing the caller output. It is not linked into the firmware and cannot enable the load.

Matching table nodes verifies transcription and implementation only. Interpolation error between nodes is not specified by the manufacturer. Resistance tolerance, pull-up error, ADC error, attachment gradients, self-heating and installed thermal lag still require an error budget and physical qualification. Never clamp an out-of-range reading to make it appear valid.